NO. ITEM

POOLS

71 POOL TYPE 1 - CTS4 PARKRIDGE
FACILITIES POOL.

(PT1)

7.2 POOL TYPE 2 - CTS1 PARKRIDGE
TERRACES POOL.

(PT2)

7.3 POOL TYPE 3 - CTS3 PARKRIDGE
VILLAS PLUNGE POOLS.

(PT3)

STRUCTURES

8.1 STRUCTURE TYPE 1 - CTS4
FACILITIES POOL AREA.

(S81)

8.2 STRUCTURE TYPE 2 - CTS1
TERRACE RESIDENCES POOL
AREA.

(S$2)

8.3 STRUCTURE TYPE 3 - CTS1
TERRACE RESIDENCES SUNKEN
LOOK OUT.

(SS3)

STRUCTURES

9.1 GREEN ROOF TYPE 1. EXTENSIVE.
FACILITIES BUILDING (GR1).

9.2 GREEN ROOF TYPE 2. EXTENSIVE.
TERRACE RESIDENCES ENTRY
PORTICOS (GR2).

9.3 GREEN ROOVES IRRIGATION.

(GR1 & GR2).

GLASS REINFORCED CEMENT POT PLANTER

10.1

 

GRC POT PLANTER TYPE 1.
POOL AREA.

PRODUCT DESCRIPTION

25X10M POOL.

25X5M POOL.

CTS2 PARKRIDGE VILLAS PLUNGE
POOLS.

18X6M (CABANA STRUCTURE).

10X5M (STRUCTURE).

5X5M (STRUCTURE).

GREEN ROOF TYPE 1. RAISED
PLANTER 450MM MINIMUM DEPTH
VARIES. BUILDING STRUCTURE
CONTAINED.

GREEN ROOF TYPE 1. RAISED
PLANTER 350MM MINIMUM DEPTH
VARIES. BUILDING STRUCTURE
CONTAINED.

GREEN ROOVES IRRIGATION.
(GR1 & GR2).

POT PLANTER TYPE 1. TRELLIS
GLASS FIBRE REINFORCED
CONCRETE PLANTER BOX
2000X1600X500MM. TO SIT ON
TILING.

P 07 5309 6002 E [email protected]

FINISH

STRUCTURE: CONCRETE TO ENGINNER'S SPECIFICATION.

SET OUT & DEPTHS: REFER TO PLANS.

LANES. ALLOW FOR TWO LANES TO MEET REGULATION WIDTH, DEPTH AND 25M LENGTH.
FINISH: PEBBLECRETE COLOUR 'SKY BLUE’. COPING & EXPOSED EDGES: CONTINUE
ADJACENT TILE FINISH. SAMPLE TO BE APPROVED BY LANDSCAPE ARCHITECT.

STRUCTURE: CONCRETE TO ENGINNER'S SPECIFICATION.

SET OUT & DEPTHS: REFER TO PLANS. LANES. ALLOW FOR TWO LANES TO MEET
REGULATION WIDTH, DEPTH AND 25M LENGTH.

FINISH: PEBBLECRETE COLOUR 'SKY BLUE’. COPING & EXPOSED EDGES: CONTINUE
ADJACENT TILE FINISH. SAMPLE TO BE APPROVED BY LANDSCAPE ARCHITECT.

STRUCTURE: CONCRETE TO ENGINNER'S SPECIFICATION.

SET OUT & DEPTHS: REFER TO ARCHITECT'S PLANS.

FINISH: PEBBLECRETE COLOUR 'SKY BLUE’.

TILE LINE: GLASS MOSIAC TILE COLOUR TBC. COPING & EXPOSED EDGES: CONTINUE
ADJACENT TILE FINISH. SAMPLE TO BE APPROVED BY LANDSCAPE ARCHITECT.

18X6M ROOF STRUCTURE WITH 3NO. 4600X4600 CUBANA ROOMS DIVIDED BY 1400MM
GARDEN AND ROOF STRUCTURE INTERNALLY AND 700MM WIDE GARDENS AND ROOF
EXTERNALLY. SET OUT: REFER TO PLANS. STRUCTURE: TO ENGINEER'S SPECIFICATION.
FRAME: STRUCTURAL STEEL POWDERCOATED (COLOURBOND) MONUMENT. ROOF: 75X75
HWD TIMBER BEAMS WITH DANPALON POLYCARBONATE ROOFING. WALLS: 3N0. BEING
BACK AND SIDES 42X30MM HWD TIMBER SLATS AT 42MM GAPS.

10X5M ROOF STRUCTURE WITH 2NO. 5X5 ROOMS DIVIDED BY 1.5M STONE WALL. SET OUT:
REFER TO PLANS. STONE WALL: MASONRY BLOCK WALL CLAD WITH NATURAL STONE
(ECO OUTDOOR) PRODUCT: RANDOM ASHLAR TYPE:COOLUM. STRUCTURE: TO
ENGINEER'S SPECIFICATION. BEAMS: 300X100MM HWD TIMBER. CENTRAL POSTS TO TOP
OF STONE WALL: 300X100MM HWD TIMBER WITH STEEL BLADE SUPPORT. ROOF:
DANPALON POLYCARBONATE ROOFING. COLUMNS: 4NO. OFF FORM CONCRETE COLOUR
(BORAL) TUNGSTEN. REFER TO FUTURE DESIGN INTENT.

5X5M CANTILEVERED ROOF STRUCTURE SET OUT: REFER TO PLANS.

BEAMS: 300X100MM HWD TIMBER. POSTS TO ONE SIDE (AS SHOWN ON PLAN): 300X100MM.
STRUCTURE: TO ENGINEER'S SPECIFICATION ROOF: DANPALON POLYCARBONATE
ROOFING. COLUMNS: 1NO. (IF REQUIRED STRUCTURALLY) OFF FORM CONCRETE
COLOUR (BORAL) TUNGSTEN. (BEHIND VIEW LINE). REFER TO FUTURE DESIGN INTENT.
BUILT IN OFF FORM CONCRETE SEAT 450MM HIGH AND 500MM WIDE TO TWO SIDES
(REFER TO PLAN FOR SET OUT). COLOUR (BORAL) TUNGSTEN.

PLANTER DEPTH:MINIMUM 450MM DEPTH

PLANTER PROFILE (TOP TO BOTTOM): 25MM STONE MULCH, (REMAINING DEPTH)
HYDROCELL 40 PODIUM MIX, 60MM HYDROCELL RG30 FOAM LAYER, WRAP BASE AND
WALLS WITH GEOTEXTILE MEMBRANE, 20MM DRAINAGE CELL ON BASE AND 2.5MM
COREFLUTE SHEETS ON WALLS AND LDPE SHEET PROTECTION FOR WATERPROOFING
MEMBRANE TO BASE AND WALLS. WATERPROOFING MEMBRANE TO ENGINEER'S
SPECIFICATION. IRRIGATION: IRRIGATION TO BE DESIGNED AND INSTALLED BY SUITIBLY
QUALIFIED PERSON TO THE APPROPRIATE STANDARDS. REFER TO PLANTER IRRIGATION
ITEM DETAIL BELOW FOR ALL PLANTERS. PLUMBING THROUGH BUILDING TO BE INSTALLED
BY BUILDER. DRAINAGE: ALL RAISED PLANTERS TO HAVE DRAINAGE ALLOCATIONS WITHIN
THE BUILDING STRUCTURE AT REGULAR INTERVALS TO ENGINEER'S SPECIFICATION.
REFER TO DETAIL. FOR PLANT TYPES REFER SYMBOLS TO PLANTING SCHEDULE.

PLANTER DEPTH:MINIMUM 350MM DEPTH

PLANTER PROFILE (TOP TO BOTTOM): 25MM STONE MULCH, (REMAINING DEPTH)
HYDROCELL 40 PODIUM MIX, 60MM HYDROCELL RG30 FOAM LAYER, WRAP BASE AND
WALLS WITH GEOTEXTILE MEMBRANE, 20MM DRAINAGE CELL ON BASE AND 2.5MM
COREFLUTE SHEETS ON WALLS AND LDPE SHEET PROTECTION FOR WATERPROOFING
MEMBRANE TO BASE AND WALLS. WATERPROOFING MEMBRANE TO ENGINEER'S
SPECIFICATION. IRRIGATION: IRRIGATION TO BE DESIGNED AND INSTALLED BY SUITIBLY
QUALIFIED PERSON TO THE APPROPRIATE STANDARDS. REFER TO PLANTER IRRIGATION
ITEM DETAIL BELOW FOR ALL PLANTERS. PLUMBING THROUGH BUILDING TO BE INSTALLED
BY BUILDER. DRAINAGE: ALL RAISED PLANTERS TO HAVE DRAINAGE ALLOCATIONS WITHIN
THE BUILDING STRUCTURE AT REGULAR INTERVALS TO ENGINEER'S SPECIFICATION.
REFER TO DETAIL. FOR PLANT TYPES REFER SYMBOLS TO PLANTING SCHEDULE.

GREEN ROOF IRRIGATION: IRRIGATION TO BE DESIGNED AND INSTALLED BY SUITIBLY
QUALIFIED PERSON TO THE APPROPRIATE STANDARDS. THE IRRIGATION SUPPLY LINE TO

SUPPLIER

NOMINATED BY CONTRACTOR TO
BE APPROVED BY
SUPERINTENDENT.

NOMINATED BY CONTRACTOR TO
BE APPROVED BY
SUPERINTENDENT.

NOMINATED BY CONTRACTOR TO
BE APPROVED BY
SUPERINTENDENT.

NOMINATED BY CONTRACTOR TO
BE APPROVED BY
SUPERINTENDENT.

NOMINATED BY CONTRACTOR TO
BE APPROVED BY
SUPERINTENDENT.

NOMINATED BY CONTRACTOR TO
BE APPROVED BY
SUPERINTENDENT.

FYTOGREEN

1300 182 341

CONTACT: STUART TYLER
PH: 0407818074

FYTOGREEN

1300 182 341

CONTACT: STUART TYLER
PH: 0407818074

FYTOGREEN
1300 182 341

BE DEDICATED TO GARDEN IRRIGATION ONLY NO SUPPLEMENTARY TAPS TO BE FITTED. THE CONTACT: STUART TYLER

IRRIGATION CONTROLLER TO BE AUTOMATED WITH REMOTE MONITORING CAPACITY AND
LINKED TO PULSE FLOW METER. AUTOMATED IRRIGATION SYSTEM CONNECTED TO RAIN
WATER HARVESTED RESERVOIR. EACH ZONE PRESSURE REDUCED AT THE SOLENOID. ALL
PRESSURE REDUCING AND SOLENOID VALVES TO BE LOCATED AT EACH SEPERATE
PLANTER ZONE WITH CONDUIT AND DATA CABLE BACK TO CONTROLLER FOR ACTIVATING

THE SOLENID. EACH PLANTER TO HAVE WATER TAKE OFFS VIA CENTRAL CONTROLLER WITH
DAILY BACK TO BASE MONITORING. EACH WITH 25MM RISER AND LATERALLY AT EACH LEVEL

20MM WITH BSP THREAD TO EACH PLANTER REDUCED TO 13MM AND SUB SOIL DRIP LINES
AT 300MM CENTRES AND LINKED BACK TO BACK. PIPE SIZING SHOULD REFLECT THE FLOW
RATE BY ZONE AND TERMINATE IN THE PLANTER WITH A 20MM BSP THREAD. CONTROLLER

TO HAVE BACK FLOW PREVENTION, INLINE FILTERS AND WATER METER. IRRIGATION SYSTEM

TO BE DESIGNED AND APPROVED BY PLANTER INSTALLER. PLUMBING THROUGH BUILDING
TO BE INSTALLED BY BUILDER.

PLANTER TYPE: 'QUATRO DESIGN' 500 SERIES CUSTOM PLANTER BOX 2000X1600MMX
H500MM. PLANTERS TO HAVE 25MM BLOCK FEET. COLOUR: CONCRETE GREY (STANDARD
COLOUR RANGE) OR APPROVED SIMILAR. PLANTER SOIL PROFILE (TOP TO BOTTOM):
25MM STONE MULCH, (REMAINING DEPTH) HYDROCELL 40 PODIUM MIX, 60MM HYDROCELL
RG30 FOAM LAYER, WRAP BASE AND WALLS WITH GEOTEXTILE MEMBRANE, 20MM
DRAINAGE CELL AND LDPE SHEET PROTECTION FOR WATERPROOFING MEMBRANE.
WATERPROOFING MEMBRANE TO MANUFACTURER'S SPECIFICATION.

IRRIGATION: IRRIGATION TO BE DESIGNED AND INSTALLED BY SUITIBLY QUALIFIED
PERSON TO THE APPROPRIATE STANDARDS. REFER TO PLANTER IRRIGATION ITEM
DETAIL ABOVE FOR ALL PLANTERS. PLUMBING THROUGH SLAB TO BE INSTALLED BY
CONCRETE CONTRACTOR. DRAINAGE: ALL POT PLANTERS TO HAVE DRAINAGE
ALLOCATIONS WITHIN THE SLAB BELOW TO ENGINEER'S SPECIFICATION TAPPED TO
STORM WATER PIPE. REFER TO DETAIL. FOR PLANT TYPES REFER SYMBOLS TO PLANTING
SCHEDULE.

PH: 0407818074

QUATRO DESIGN
CONTACT: CHRIS NORTH
PH: 02 66721190

FYTOGREEN

1300 182 341

CONTACT: STUART TYLER
PH: 0407818074

 

DATE ISS DESCRIPTION

 

27.11.17 D FOR OPERATIONAL WORKS APPROVAL MG
15.09.17 C FOR OPERATIONAL WORKS APPROVAL MC
21.06.17 B FOR CLIENT REVIEW MC
18.08.17 A FOR CONSULTANT REVIEW Mc

CHKD | CLIENT

 

ALTUM CONSTRUCTIONS

 

PROJECT

PARKRIDGE NOOSA QLD
CTS2 PARKRIDGE VILLAS

 

LANDSCAPE DOCUMENTATION PACKAGE

SCHEDULE OF FINISHES

 

PROJECT. NO. DWG. NO. ISSUE

402

A1 NA

©) LP0O2 D

 

 

© COPYRIGHT tis pRAWING Is COPYRIGHT AND THE PROPERTY OF CONLON GROUP PTY. LTD. AND MUST NOT BE RETAINED, COPIED/REPRODUCED OR USED WITHOUT WRITTEN AUTHORITY.

FOR OPERATIONAL WORKS APPROVAL

Used in these records

About this file

File size
12.9 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Landscape Plans Pt 1.pdf · 12.9 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.