Detached Housing Zone Code
____________________________________________________________________________________________________________________
ACCEPTABLE
SOLUTION ALTERNATIVE SOLUTIONS / COUNCIL USE
SPECIFIC OUTCOMES PROBABLE SOLUTIONS
COMPLIANCE COMMENTS ONLY
(/)
c) ensure the protection of persons and specified level;
property in the event of a flood and b) for areas where flood modelling is
power failure; available—a minimum of 500mm
d) ensure drainage does not adversely above the modelled flood level; and
impact upon other premises; and c) for areas where flood modelling is not
e) ensure filling, excavation or retaining available, a minimum of 500mm
structures do not adversely impact above the highest known flood
upon other premises by— level;
17
i. causing ponding of water on the AND
site or nearby land; and
ii. increasing flooding, which S2.2
adversely affects the safety or use
of any land upstream and Enclosed car parking and manoeuvring Water from the proposed garage and
downstream; and areas are constructed at a level that driveway will drain to the street.
iii. adversely affecting the flow of permits the parking area to drain from the
water in any overland flow path; site by gravity means, without the need for
iv. adversely affecting the privacy or mechanical pumping;
visual amenity of surrounding AND
properties.
AND S2.3
Filling, other than accessways, does not Filling will not exceed 1m
extend more than 1m beyond the footprint
of any building or structure, measured
from the outer walls of the building or
structure.
O3