Original source · versioned page text
Appendices B-D
Attached to the e-mail MCU15/0023 Development application (Email 2 of 2).
Original PDF page 66, section 1. The text section number identifies this passage in the reader.
Natural Hazards Overlay Code
____________________________________________________________________________________________________________________
ACCEPTABLE
SOLUTION ALTERNATIVE SOLUTIONS / COUNCIL USE
SPECIFIC OUTCOMES PROBABLE SOLUTIONS
COMPLIANCE COMMENTS ONLY
(/)
O8 S8.1
An adequate and accessible water supply For premises not in a water service N/A Not applicable. The site is in a water
is provided for fire fighting purposes. area— each lot has an accessible dam, service area.
swimming pool or water tank accessible
by the fire brigade that contains at least
5000 litres of water.
13.36 VEHICLE ACCESS AND FIRE TRAILS
Firebreaks and fire access tracks
O9 S9.1
Firebreaks or fire access tracks provide— Firebreaks are provided by—
a) adequate access for fire fighting and a) a cleared road reserve not less than
other emergency vehicles; and 20m wide located around the
b) adequate width to minimise the risk of perimeter of the development;
fire crossover. OR
b) fire access tracks between the
development and surrounding
vegetated lands that—
i. are a minimum cleared width of
6m;
ii. have a maximum grade of 1 in 8
(12.5%) ;
iii. have a formed pavement;
iv. have access at each end and in
Noosa Plan - Code Compliance
See the original
The page text is free to read. Viewing or downloading an original file needs an account.