URD CONDUIT SCHEDULE - ROADWAYS - BY CIVIL CONTRACTOR EE
X-SEGTION in) LOCATION Frown, |vauts} ex | Rec | im inv J iv REMARKS
aay COTE) PVC CABLE KErB ail [itAT2s0XSH] 1 1CT 185KSH]LVAA2AOXPV] LVCA7GKH |LVCaI6XPV JLVC210PVPV]LVG24PVPV)
ayo ENERGEKC] PROTECTION | Excav’ | TRENCH MARK REMARKS eee MORINDA COT 7 aw z 2 lect 2
40mm | yy, | 00mm} | 125MM | | 4 (m) TAPE | DETAR | © 3 4 iv x 35
HD ft wo ae
Comms MD IMORINDA CCT/SHIREDvE| + | @ | W = 14a
ery aia zi a D |2 2 1[uf]w . 180 EXPRESS OCT 9
ie zm [2 i|_ 3s 2 2 z 2 za ene OVE o [0 | w 7 =
1 | 33 a [i] os fil 2 o & H 2 _|INSTALL CONDUITS UNDER SAV s eee ee ee : ae
1 | aA aw [a 1| 2 28 2 4 2 _|NSTALL CONDUITS UNDER SW 2 | 16 | 7 2
% | wi] s [1] 6 [4 8 18_| DP | 2 [INSTALL CONDUITS UNDER SW 6 eraRE OVE ne |v : a
INSTALL ELEC, CONDUITS UNDER SW ca ia Sa : am
zo | 2 a l|il a jel 2 2 L 2 |PIPE AT EXTRA DEPTH DUE TO 2 — sale iealae ; a
wa | 2B 10 ® 2 D 2 9 25_|_2 | Wv : 2
[Ail STREETS. ATPLIARS | _Lv : 29 BRIOGING
IBESIDE LOT 147 wa] 2 | a5 ]1] a | 1] 5 |e] os % 35 x 35 micas oe 5 5
TOTAL 0 212 w92 14 190 109 “ 199 [SUB-TOTAL | 700 “7 268
Mutts [VARIANCE 4% 2 6 "
1. ROAD CROSSING CONDUITS SHALL BE INSTALLED STRICTLY IN ACCORDANCE WITH THE ENERGEX UNDERGROUND DISTRIBUTION CONSTRUCTION (UDC) MANUAL.
2. ROAD CROSSING CONDUITS SHALL HAVE A MINIMUM COVER OF 800mm AT ALL PLACES UNDER THE ROAD, EXCEPT UNDER STATE-CONTROLLED "MAIN" ROADS, rota | me 153 27 |QoTRENCH 887m
WHERE CONDUITS SHALL HAVE A MINIMUM COVER OF 1200mm_
3. CONDUITS SHALL EXTEND TO WITHIN 00mm OF PROPERTY ALIGNMENT; PVC PROTECTIVE COVER STRIPS SHALL BE LAID ABOVE ALL ROAD-CROSSING CONDUITS NOLES.
ice Den nEtewee 1. THE CONTRACTOR SHALL MEASURE ACTUAL CABLE LENGTHS REQUIRED, AFTER INSTALLATION OF CONDUITS, THEN ORDER CABLE ACCORDINGLY.
4. REFER ENERGEX UDC MANUAL V.5 SECT. C2 FOR CROSS-SECTION DETAILS.
5. BRASS “E* MARKERS SHALL BE INSTALLED IN KERBS DIRECTLY ABOVE ELECTRICITY CONDUITS.
6. CAUTION: DO NOT CONSTRUCT RETAINING WALLS, CONCRETE PATHS OR WATER SERVICES UNTIL FOOTPATH CONDUITS HAVE BEEN INSTALLED. EQUIPMENT SCHEDULE - SERVICE PILLARS
LOCATION S| sie.o. | ex | rec | in SIZE AND DESCRIPTION jeomP! cuse |ary REMARKS
URD CONDUIT SCHEDULE - FOOTPATHS - BY ELECTRICAL CONTRACTOR eer Fal ecm | <—latonn lV GARE TERT Twican | a core naw LET
INDA C61
X-SECTION im) +_|ivFuses osivrar | 2
CONDUIT LENGTH (m) ec capes KERB 2 | _uiss0003 > [SWAY PILLARS SA Pit_| LvSPO-6SL | 1
STATIONS
rt FROM -TO ENERGEX | PROTECTION | EXCAV: | TRENCH |MARK Faeaeee FENCH 3 | urssoo4 ~_[TWAY PILLAR, SA & MEN Pit | LvsP2est | 1
Ommim | 44, | 100mm Ty, | 125MM | | soomm (em) TAPE | DETAR | © 1011-2 1
40 to to Comms MD} 4 01340005 = _|GROSS-ROAD PILLAR & SA. Pi [LvsPi26sl| 1
IMORINDA CCT aaa ats a D Tl [SHIRE OVE 6 | _v1940086 = _|SWAY PILLARS S/L Pi_| LvsPoest | 1
wa | ar | [1| @ |e] o [1] @ 26 [JOIN TO EX STN TA a 7_|_Uis40087 = _|2WAY PILLAR & Si Pit_| LvSP4esi | 1
ai | 5 e fe] 6s] 6 e a 6 @ | Uras0088 > |tWAY PILLAR, S/.& MEN Pi | LvsP2est | 1
|SHIRE OVE 6 at 1 ~ Do ~ 4011-2 1
isnME SaaS CL GaSa Ts as P = 10 | U1940090 7 [2WAY PILLAR, SA. & MEN Pir [tversoat [3
eo eae = 2 = 11 | Uras0100 > [2WAY PILLAR, SA. & MEN Pit | LVSP46SL | 1
6 a a 1 8 2 °o a 1011-2 1
6 [em [7 [it 7 fat 7 [at 7 7 z 7 12 | _Ursaoi0r +_|2WAY PLLAR® Si Pi_| LvsPaest | 1
| 10L4 $3 | 2) 53 |1 53 53 J 53 IMULBERRY CL 15 | U1s40102 * |2WAY PILLARS Si. Pii_| LVSP46sL | 1
ee Se ee = 2 ui 2 16 | Uisa0103 + |CROSS-ROAD PILLAR & SA Pit_|LVSPI26SL| 7
a ma Le = z -, 17 _|_Uis«0104 + |2WAY PILLARA SA Pir_| LvsPaest | 7 TOTALS
=i ee eee = = 16 | U13«0105 > |TWAY PILLAR, S/. & MEN Pit] LvSP26SL | 1 LVSP12-681 x 4
wz | mei] « {[1{| « [il « fa 4 4 4 1011-2 1 ineekealea
ee EXISTING CONDUITS AT} ITWIGRUSH CAT 2 U1340106 + J2WAY PILLARS SL Pit | LVSP46SL [1 LVSP448t «9
wo | 14 w ]1] w |a] 10 " Reet ariecany oni 10 + _|CONVERSION SET Pir_| uvspcews |_1_|FUTURE 3 WAY PILLAR. LVSPO-4SL x 2
TO BE CONFIRMED ON SITE 2 | Uisa107 ~_[2WAY PILLAR, S/& MEN Pa | Wvapreet [1 LVPTéCaN0 x 2
IMILLBERRY CL 10 jOL2 1 10 1 10 Pp 10 cs
oe is a : 7 | _Uis0108 + |GROSS-ROAD PILLAR & SA. Pii_[LvsPi2-6st| 1 ieee: s
So rae a 7 = 24_| _U1s0100 7 _2WAY PRLARS Si. Pi_| LvsPaest | 1 ee
0405" 1
oo aaa bee a D a 2 | Urseo110 > [1 WAY PILLAR, S/.& MEN i | tyereeet | eused
ee a eth 2 ‘ zoel 7. 2 5 z 26_| _Uisont = |GROSS-ROAD PILLAR & SA. Pli_[uvsPiz-6st| 1 19602 x 6
cere Seale 5 n aa |VARIOUS LOCATIONS CABLE MARKER PLATES 1350-2 | 6 [INSTALL STNS 171, 20A, 25.
2% | BA 10 |2 0 E ©
axel Seat a a a STREET LIGHT SCHEDULE - RATE 2
s a 5 1 5 1 6 P 5 POLE OR COMPONENTS OUTREACH BRACKET
wa | wf 16 D 18 sm — = Mount
LOCATION: ‘SITE LD. |comP' ‘ALIGN REMARKS:
PATHWAY 2 [aa | li] [1] » |e] @ a” |x INSTALL PVC STRIP 7 ne tor |e | vor red | ree | S80 | Lose [to | 25 | tween louse, hase |ousn:| °° |Fom | en [oe | cee | orm
‘AT PILLARS @
At STREETS apoes | ® |! oo eu VRC ERSTE ATS || © lucrinna cor ‘ay | Prowne| Por as [estate | sures | 10 | str ‘srooatz [woos | simoass 81 _ [em anapron
TOTAL pn ns 300 2 106 608 ‘& | Prowra| Por as [estate | sums | 40 | sir ‘S100al2 |Noos | sumeat1 1 err ADAPTOR
[sian OVE 73 | Prone | Pot a [este | cums | 10 | et Sroanla [woos | alee 1) prragapton
1. CONDUITS SHALL BE INSTALLED WITHIN A CORRIDOR 300-900mm FROM PROPERTY ALIGNMENT, IN ACCORDANCE WITH ENERGEX UNDERGROUND DISTRIBUTION =: leeers eo ae ee ee ee ee at Firswron
CONSTRUCTION (UDC) MANUAL. 712 | Prowse | Por 46 [estate| swiss | 10 | str sraz_|noos | smer7s at AVENUE
2. FOOTPATH CONDUITS SHALL HAVE MINIMUM 750mm COVER, , REGARDLESS OF ENERGEX’S REQUIREMENTS, | rome] Por 452] SOTAve | eeeores | co: | eee eel eae a AVENUE
9. CONNECT EXISTING CONDUITS, INCLUDING ROAD CROSSING CONDUITS, TO NEW FOOTPATH CONDUITS 1041 | Prsvorss | Por a5 [esiare| anes] 10 | a1 s7a@az |roos | amos 61 AVENUE
| 4, TELECOMMUNICATION CONOUITS SHALL BE INSTALLED ABOVE THE ENERGEX CONDUITS IN A JOINT USE TRENCH ARRANGEMENT. vi | Prssore| por as [estate| sows | x0 | a a or is buocwene TOTALS
¥4_| Pissoize | Por as [estate| amaas | vo | ae Sana [cos | Smee Bi fauack avenue SLME149 x 16
Mua RERRY ci ya? | Pxsaows | Por a5 [estate | simmas| 10 | sit Foma2 |Noos | Siamasra &1 feACK AVEME SLMES8-3 x 1
+a | Prseaaa | Por oe Go oe Fase? |Noos | Sima 1 lauacK AVENUE. SLMB41-1 x 4
a | Praaovaa | Pow as [estate| simran] x0 | sir Faaxae [woos | simnasia 31 back AVENE SiMe179 x 1
fwacausu car Zits | Prssorea | Por 4s [estate| sussras | 10 | sur Fada [Noos | suvess+4 a names ae a es
‘2a | Prssor25 | Por 45 | ESTATE | Simeres 10 Sut Faaa2 [MOOS | StMess14 ‘61 [BLACK AVENUE 813168 x 4
24_| Prowrze | Por <5 [estate| siusres | 10 | sit Fsaa2 |noos | simacst< Bt LACK AVENUE erate ae
ea. | Prsenne7 | Por 45 [estate| amors| x0 | st Foaaz |[Noos | Sume«s14 31 fatAcK AVENUE Menai as
IPATHWAY ait2 | Piso | Por ‘30 | Mince | sumeses JasPaTH| sur Fozoa2 |noos | sumess+4 0 en 811600 x 1
NOTES:
1. ALL LIGHTS TO BE CONNECTED ON ENERGEX RATE 2
2. CHECK GLEAR OF ALL SERVICES BEFORE EXCAVATING
3. SL POLE SETBACKS TO BE MEASURED FROM INVERT OF KERB (LOK) MINIMUM
DATE | REV | REVISION APP. | DATE | REV | REVISION APP. | CURRENT REVISION CHANGES: ey | NCSA DESIGNED =| A HOBBS DESCRETION tocaTIOn ‘DRAINS Ne
. ELECTRICAL.
poet] SAS | Deane Ba oben tog ome now Robin Eaters counc. _feneaccnsTacs [Ommn | Tmeoatremon | ELECTRICITY SCHEDULES DOONELLA NOOSA - STAGE C1 - C3 A992-02B
wanveo4] 8 | FOR TENDER RR Russell Te onserasess OUNCE REF | 23616DA nepRoVED By | ROBNRUSSELL BECKMANS ROAD a
fee pian RPEO (FORTENDER BENE PROEST
& ASSOCIATES PTY. LTD. basetsonn WORE “eo Tecan - on NOOSAVILLE . ae
canoes : Rowe
zi x 7 NORFOLK ESTATES P/L_ATF THE ‘THES DOCUMENT iS COPYRIGHT AND THE | oF
COMBLLING ENGREERS-ELECTREAL AEX ORS va Gai \Wacaieee TE Taal GOR Nit RR TW DOGRERT CoPYROM NOTH TROPERTY FF REA ASSOOATES PVD [A1 $0104576 22
= : oo
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.