Original source · versioned page text
2017-06-06 - P&E Agenda Attachment 1 to Item 6 Draft Alignment Amendments Part 4 (Pages 916-937)
Text sections have not been matched to the original PDF pages. Use the original document to check page numbers.
2nd Round Amendments proposed by Council 11 October 2007
SCHEDULE 1—MINIMUM BOUNDARY SETBACKS FOR
Including amendments to 3 July 2017
The Noosa Plan
BUILDINGS AND OTHER STRUCTURES
1. Table 1-1 lists Standard minimum boundary setbacks for zones.
Table 1-2 lists Exceptions for specific premises.
Table 1-3 lists Exceptions for specific uses.
2. The minimum boundary setbacks in the tables apply to—
a) each building on a premises; and
b) structures whether or not located on the same premises as a building.
3. However, subsection 2 does not apply to—
a) class 10a buildings, except in relation to—
i garages and carports in front setback areas;
ii class 10a buildings in the Rural and Rural Settlement Zones;
1
iii Coastal Protection Precinct setbacks in Table 1-2; or
iv Noosa Waters Estate setbacks in Table 1-2.
b) class 10b structures 1m or less in height if—
i a screen or fence 2m or less in height; or
ii rainwater tanks 2.4m or less in height in the Rural and Rural Settlement
Zones.
4. The setbacks in more than 1 table may apply.
5. If there is a conflict between minimum boundary setbacks in Table 1-1, Table 1-2 or Table
1-3, the greater boundary setback prevails.
6. If there is a conflict between the minimum boundary setbacks in Table 1-1, Table 1-2 or
Table 1-3 and the conditions of an existing development permit affecting the siting of
buildings on the premises, including an approved building envelope for the premises, the
conditions prevail.
2
Table 1-1—Standard minimum setbacks for Zones
column 1 Column 2
Zone Minimum setbacks
Detached Housing Zone Frontage—6m
Rear boundary─
2
a) where the lot has an area of at least 550m rear
setbacks comply with either: ─
i) 3.0m setback up to 4.5m height; and 6.0m
setback between 4.5m -8.0m height OR
ii) no part of the building protrudes beyond a
1
The Coastal Protection Precinct is shown on the Natural Resource Overlay Maps for certain localities.
2
If there are no applicable setbacks in either Tables 1-1, 1-2 or 1-3, the siting provisions of Parts 11 and 12 of the
Queensland Development Code apply.
S1-1