Original source · versioned page text
Engineering Code Assessment Report
Original PDF page 42, section 1. The text section number identifies this passage in the reader.
c7:M1-2400 2400 CPIUT MB (BA)
Mains Cable Plan
AL
N
MA
ST
W E
PTUS 3558M01 07/2024(AA)
PTUS 3558M01 07/2024(AA) 3005:AH-AJ/1-24 24F/- SMOF FNPEHJ/STD <- (AA) S
3003:AH-AT/1-12 12F/- SMOF FNPEHJ/STD <- (AA)
3003:AH-AJ/1-12 12F/- SMOF FNPEHJ/STD <- (AA)
3003:AA-AB/1-6 6F/- SMOF FNPEHJ <- (AA)
2xOC (BA)
AA BA
BA2 BA1
2xP32 SUBDUCTS (BA)
AN
OC OPTUS 3558M01 07/2024 (BA1)
P100
GL
OC IX1392 MO3 10/2027 (BA2)
ER
ST
50DEAD 50 CPIUT MB (AA)
3005:AH-AJ/1-24 24F/- SMOF FNPEHJ/STD (AA)
AA
3003:AH-AJ/1-12 12F/- SMOF FNPEHJ/STD (AA)
LER
3005:AR-AH/1-120 120F/- SMOF FNPEHJ/STD (AA) P50 3003:AA-AB/1-6 6F/- SMOF FNPEHJ (AA)
PTUS 3558M01 07/2024(AA) 3501:AA-AH/1-60 60F/- SMOF FNPEHJ/STD (AA) 2xOC (AA)
3003:AA-AB/1-6 6F/- SMOF FNPEHJ (AA)
ANG
2xP32 SUBDUCTS (AA)
OC OPTUS 3558M01 07/2024 (AA1)
A
OC IX1392 MO3 10/2027 (AA2)
UNG
50DEAD 50 CPIUT MB (AA)
c12:M1-1200 1200 CPIUT MB (AB) 3005:AH-AJ/1-24 24F/- SMOF FNPEHJ/STD (AA)
P15 300/1800 c7:M1-2400 2400 CPIUT MB (BA) 3003:AH-AJ/1-12 12F/- SMOF FNPEHJ/STD (AA)
ATT
1xP32 SUBDUCTS (BB) 3003:AA-AB/1-6 6F/- SMOF FNPEHJ (AA)
OC TELD05710 MO1 9/2029 (BB1) AA
2xOC (AA) 3003:AA-AB/1-6 6F/- SMOF FNPEHJ (AA)
3003:AH-AJ/1-12 12F/- SMOF FNPEHJ/STD (AA)
A100 AA
3005:AH-AJ/1-24 24F/- SMOF FNPEHJ/STD (AA)
P50 50DEAD 50 CPIUT MB (AA)
2xOC (AA)
AC BC
ST
AB BB BB1
AA BA
AA2 AA1
50DEAD 50 CPIUT MB (AA) 50DEAD 50 CPIUT MB (AA)
AA 3005:AH-AJ/1-24 24F/- SMOF FNPEHJ/STD (AA) 3005:AH-AJ/1-24 24F/- SMOF FNPEHJ/STD (AA)
P100CE A100 3003:AH-AJ/1-12 12F/- SMOF FNPEHJ/STD (AA) 3003:AH-AJ/1-12 12F/- SMOF FNPEHJ/STD (AA)
3003:AA-AB/1-6 6F/- SMOF FNPEHJ (AA)
3003:AA-AB/1-6 6F/- SMOF FNPEHJ (AA) AA
2xOC (AA) 3xOC (AA)
P50
29.6
4
37.4
50DEAD 50 CPIUT MB (AA)
3005:AH-AJ/1-24 24F/- SMOF FNPEHJ/STD (AA)
4 3003:AH-AJ/1-12 12F/- SMOF FNPEHJ/STD (AA)
42.0 3003:AA-AB/1-6 6F/- SMOF FNPEHJ (AA)
AA
2xOC (AA)
P50
4 35.0
W
50DEAD 50 CPIUT MB (AA) Y
3005:AH-AJ/1-24 24F/- SMOF FNPEHJ/STD (AA) 2
3003:AH-AJ/1-12 12F/- SMOF FNPEHJ/STD (AA) 39.0
43.6
3003:AA-AB/1-6 6F/- SMOF FNPEHJ (AA)
3xOC (AA)
19.5
AA
2
A100 20.4
2
4
OC[15mm](AA)
20.2
2
20.5
3
MA
50DEAD 50 CPIUT MB <- (AA) 20.0
AL
3005:AH-AJ/1-24 24F/- SMOF FNPEHJ/STD <- (AA) REPAIR JOINT 3.0m 3
3003:AH-AJ/1-12 12F/- SMOF FNPEHJ/STD <- (AA) AA FROM 3 PIT DR
3003:AA-AB/1-6 6F/- SMOF FNPEHJ <- (AA) 3
3xOC (AA) P50
2xOC (AA)
3005:AH-AJ/1-24 24F/- SMOF FNPEHJ/STD (AA) 5
50DEAD 50 CPIUT MB (AA) 3003:AH-AJ/1-12 12F/- SMOF FNPEHJ/STD (AA) AA
3005:AH-AJ/1-24 24F/- SMOF FNPEHJ/STD (AA) 5.0
3003:AH-AJ/1-12 12F/- SMOF FNPEHJ/STD (AA) AA
3003:AA-AB/1-6 6F/- SMOF FNPEHJ (AA) P35 7.5
3003:AA-AB/1-6 6F/- SMOF FNPEHJ (AA)
TH
2xOC (AA) P35
E
50.5
QU
2xOC (AA)
3005:AH-AJ/1-24 24F/- SMOF FNPEHJ/STD (AA) B9
AR
3003:AH-AJ/1-12 12F/- SMOF FNPEHJ/STD (AA) AA VODAFONE HUT
TE
3003:AA-AB/1-6 6F/- SMOF FNPEHJ (AA) 2 38.0
P35 .5
RD
31
EC
3
K
62.3
B1
8
OPTUS HUT
.2
16
AA
A100
AB
4
2xOC(AA)
TELSTRA CMTS SITE
.0
88
AA
A100
RE
8
ST
28.3
AA
A100
5xOC(AA)
6
0m 10m 20m 30m 40m 50m 60m 70m
For all Telstra DBYD plan enquiries - Sequence Number: 102734738
email - [email protected]
For urgent onsite contact only - ph 1800 653 935 (bus hrs) CAUTION: Fibre optic and/ or major network present
TELSTRA CORPORATION LIMITED A.C.N. 051 775 556
in plot area. Please read the Duty of Care and
contact Telstra Plan Services should you require
Generated On 12/10/2020 15:33:38 any assistance.
WARNING - Due to the nature of Telstra underground plant and the age of some cables and records, it is impossible to ascertain the precise location of all Telstra plant from Telstra's plans. The accuracy and/or
completeness of the information supplied can not be guaranteed as property boundaries, depths and other natural landscape features may change over time, and accordingly the plans are indicative only.
Telstra does not warrant or hold out that its plans are accurate and accepts no responsibility for any inaccuracy shown on the plans.
It is your responsibility to locate Telstra's underground plant by careful hand pot-holing prior to any excavation in the vicinity and to exercise due care during that excavation.
Please read and understand the information supplied in the duty of care statement attached with the Telstra plans. TELSTRA WILL SEEK COMPENSATION FOR LOSS CAUSED BY DAMAGE TO ITS PLANT.
Telstra plans and information supplied are valid for 60 days from the date of issue. If this timeframe has elapsed, please reapply for plans.
Page 2 of 2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.