Original PDF page 1043, section 1. The text section number identifies this passage in the reader.

                   LEGEND
                     For more info contact a Certified Locating Organisation or Telstra Plan Services 1800 653 935


                                                     Exchange                                                                         6           D         Cable Jointing Pit
                                                                                                                                                           (number / Letter indicating Pit Type)
                                                     (Major Cable Present)

                                                     Footway Access Chamber
                                                     (can vary from 1‐lid to 12‐lid)
                                                                                                                                             EJ            Elevated Joint
                                                                                                                                                           (above ground joint on buried cable)

                                 or                  Pillar / Cabinet                                                                                       Telstra Plant in shared Utility trench
                                                     (above ground / free standing)
                                                                                                                                                           Aerial Cable
                                                     Above ground complex equipment housing (eg RIM)
                                                     Please Note: This equipment is powered by 240V Electricity                                            Aerial Cable
                                                                                                                                                           (attached to joint Use Pole eg. Power)
                                 OC                  Other Carrier Telecommunications Cable/Asset
                                                                                                                                                           Direct Buried Cable
                                 Dist                Distribution cables in Main Cable ducts
                                 MC                  Main Cable ducts on a Distribution plan                                                M              Marker Post Installed
                                                     Blocked or damaged duct.

                                                                                                                                      T or TR              Buried Transponder

                                                     Roadside / Front Boundary
                                                     2 pair lead‐in to property from pit in street 1
                                                                                                                                           MT              Marker Post, Transponder

                                                     pair working (pair ID 059)                                                                            Optical Fibre cable direct buried
                                                     1 pair dead (i.e. spare, not connected)                                              SMOF
                                                     Side / Rear Property Boundary
                                                     Property Number                                                                Some examples of conduit type and size:
                                                     Single to multiple round conduit
                                                     Configurations 1,2,4,9 respectively                                           A ‐ Asbestos cement, P ‐ PVC / Plastic, C ‐ Concrete,
                                                     (attached text denotes conduit type and size)                                 GI ‐ Galanised iron, E ‐ Earthenware
                                                                                                                                   Conduit sizes nominally range from 20mm to 100mm
                                                     Multiple square conduit                                                       P50 50mm PVC conduit
                                                                                                                                   P100 100mm PVC conduit
                                                     Configurations 2, 4, 6 respectively
                                                                                                                                   A100 100mm asbestos cement conduit
                                                     (attached text denotes conduit type and size)

                   Some Examples of how to read Telstra Plans
                                                                   ‐50‐                                                      One 50mm PVC conduit (P50) containing a 50‐pair and a 10‐pair
                                                                    10                                                       cable between two 6‐pits. approximately 20.0m apart, with a direct
                             6                                                                                6              buried 30‐pair cable along the same route
                                               P50                  30                         20.0
                                                                                       AB         AA ‐ (cable information)      Two separate conduit runs between two footway access
                                                                                       AA BA      AB ‐ (cable information)      chambers (manholes) approximately 245m apart A nest of four
                                                                                                  BA ‐ (cable information)      100mm PVC conduits (P100) containing assorted cables in three
                                        C100                                           P100
                                                                                                                                ducts (one being empty) and one empty 100mm concrete duct
                                                                                                                                (C100) along

                                                                                        245.0

                     WARNING: Telstra plans and location information conform to Quality Level ’D' of the Australian Standard AS 5488 ‐
                     Classification of Subsurface Utility Information. As such, Telstra supplied location information is indicative only.
                     Spatial accuracy is not applicable to Quality Level D. Refer to AS 5488 for further details. Telstra does not warrant or
                     hold out that its plans are accurate and accepts no responsibility for any inaccuracy shown on the plans. FURTHER
                     ON SITE INVESTIGATION IS REQUIRED TO VALIDATE THE EXACT LOCATION OF TELSTRA PLANT PRIOR TO
                     COMMENCING CONSTRUCTION WORK. A plant location service is an essential part of the process to validate the
                     exact location of Telstra assets and to ensure the assets are protected during construction works. The exact
                     position of Telstra assets can only be validated by physically exposing them. Telstra will seek compensation for
                     damages caused to its property and losses caused to Telstra and its customers.



                   Telstra Map Legend v3_7a                                                                            Page 2                                    TELSTRA CORPORATION ACN 051 775 556




Document Set ID: 23717062
Version: 0, Version Date: 01/01/1900

Used in these records

About this file

File size
40.5 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

REFERENCE DOCUMENTS - RAL25_0004 (As Published).pdf · 40.5 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.