Control Equipment Pty. Ltd

ABN 23 009 838 582

 

Leaders in Gas Detection Since 1977

SERVICE AND CALIBRATION CERTIFICATE

Customer: AirMet Scientific Pty Ltd (AIRMET) Job No: 72393
Instrument: Eagle 2 Portable Gas Detector Date: 11/01/2023
Serial No: E2HO66 Next Calibration Due; 11/07/2023
™ As per specification, this instrument should be fully calibrated
every 6 months as per manufacturer's recommendations **
Comments: Service and calibration,

Replaced faulty H2S and O2 sensors, Supplied new probe and CO2 scrubber.

The instrument has been serviced and adjusted as indicated:

 

 

 

 

 

 

 

 

 

 

 

 

Sensor / Calibration Equipment Gas Actual Signal Indication Indication Post
Input Type Used Serial No, Level Applied | Pre-calibration Calibration
Combustible Methane 50.2% LEL 19526 50.2% LEL 58% LEL 50% LEL
OXYGEN Oxygen 12.0% VOL 19526 12.0% VOL FAIL 12,0% VOL
Hydrogen Sulphide jHydrogen Sulphide 25.2 ppm 19526 25.2 ppm FAIL 25.0 ppm
Carbon Monoxide [Carbon Monoxide 50.2 ppm 19526 50.2 ppm 61 ppm 50 ppm
Carbon Dioxide —_ {Carbon Dioxide 2.5% VOL BE129155 2.50% VOL 2.80% VOL 2.50% VOL

| Service carried out by:
CONTROL EQUIPMENT PTY LTD

   
   

[M/C

GLEN MACPHERSON
Service Technician

balances calibrated by an ISO 17025 accredited Company using NIST traceable weights and meets or
exceeds the requirements af NIST Handbook 44.

121088, 121097, 121091, or 121100 dated 18th January 2019 applies.
D: Kit #92231, Test #2740564, Kit # 03610, Test # VA-19-1135 T3
A-19-11350F, VA-19-11350E, VA-19-11350D, 1M1966 Test # VA-19-11340H

Roprosentatives / Offices In:

Sydney
Hobart
Auckland

Malbourne
Adelaife
Wellington

www. controlequipment.com au

Pe el

 

Used in these records

About this file

File size
40.5 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

REFERENCE DOCUMENTS - RAL25_0004 (As Published).pdf · 40.5 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.