Disturbed or distressed vegetation None observed.
Unusual odour None observed.
Site topography and surface water As discussed in Section 3.1. No obvious stormwater drainage
drainage devices or improvements were observed.
Surface water (quality, sheens) and No surface water present.
presence of pits, ponds and lagoons
Groundwater (presence of bores and None observed.
levels)
Building construction, condition and Other than recent slab on ground metal shed construction, no
HVAC4 relevant site structures present.
Any suspect bonded asbestos- Infrequent suspect cement sheeting fragments observed as
containing materials on ground part of surface debris discussed above relating to disturbed
surfaces and bare soil patches over the southern portion of the site.
Presence of current or former No stockpiles noted. Engineered fill present as part of the
stockpiles, fill, containment areas, discussed building platform to the west of the site. Evidence of
sumps, drains and waste disposal infilling with general waste was noted in some locations within
areas the southern potential rubbish disposal area shown on Figure
13.
Evidence of cut and fill activities No other evidence of significant cut or fill activities was
observed beyond that discussed above associated with the
shed pad.
Presence and condition of chemical None observed.
containers, holding tanks, bunds.
Presence and condition of any USTs None observed.
and associated infrastructure
Any other underground structures None observed.
that may be associated with sub-
surface contamination
Condition of materials storage and None observed.
handling facilities and any solid or
liquid waste disposal areas (chemical
inventory)
Any evidence of on-site spillage of None observed.
dangerous goods and/or off-site
migration
Other AEC based upon site history None observed.
and environmental setting.
4
Heating Ventilation and Air Conditioning system
125 Lot 105 SP118458 Cooroy DSI 12062024 Rev0 Lot 105 SP118458, Cooroy, QLD, 4563
12/06/2024 24 Detailed Site Contamination Investigation
Document Set ID: 23717062
Version: 0, Version Date: 01/01/1900