5. CONCEPTUAL SITE MODEL
A CSM is the interpretation and assimilation of all site related information into assumptions and
hypotheses regarding contamination sources, subsurface contaminant distribution, and dominant
transport/fate processes (US EPA 1995). The CSM below was developed on the findings of desktop
assessment to date, walkover and resultant AEC and PCOC. The CSM is presented in Table 9 below and
graphically in Figure 15 over page.
Table 9 Conceptual Site Model
Potential
AEC Pathway Receptor PCOC
Source(s)
1 Northern night Ingestion, dermal Current and future site Physical wastes,
soil and bottles contact, inadvertent users and ecological primarily bottles and
disposal area inhalation of dust or receptors. nightsoil, and chemical
landfill gas or vapour. contamination
Stormwater runoff and Six Mile Creek Left primarily consisting of
discharge Branch and prior heavy metals,
drainage channels TRH/BTEXN,
OCP/OPP and
Leaching/vertical Groundwater asbestos. Also
migration of potential for
contaminants pathogens, PAH, PCB,
SVOC, PFAS,
nutrients and landfill
gas or vapours.
2 Southern Ingestion, dermal Current and future site Physical wastes with a
rubbish contact, inadvertent users and ecological possible range of
disposal area inhalation of dust or receptors. regulated wastes and
landfill gas or vapour. chemical
Stormwater runoff and Six Mile Creek Left contamination
discharge Branch and prior primarily consisting of
drainage channels heavy metals,
TRH/BTEXN,
Leaching/vertical Groundwater OCP/OPP and
migration of asbestos. Also
contaminants potential for
pathogens, PAH, PCB,
SVOC, PFAS,
nutrients and landfill
gas or vapours.
3 All AECs – Intermittent surface Downgradient Per above selected
groundwater flows, rainwater groundwater and PCOCs excluding inert
and infiltration and related surface flows, and larger physical wastes
stormwater transport via perched or connected consumers and, for groundwater,
surface flows permanent groundwater and ecology asbestos.
125 Lot 105 SP118458 Cooroy DSI 12062024 Rev0 Lot 105 SP118458, Cooroy, QLD, 4563
12/06/2024 30 Detailed Site Contamination Investigation