Original source · versioned page text
REFERENCE DOCUMENTS - RAL25/0004 (As Published)
Very large file (40.5 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Original PDF page 362, section 1. The text section number identifies this passage in the reader.
SAMPLE RECEIPT NOTIFICATION (SRN)
Work Order : EB2406372
Client : ENVIRONMENTAL ADVISORS Laboratory : Environmental Division Brisbane
Contact : ANDREW WINTERS Contact : Customer Services EB
Address : PO BOX 505 Address : 2 Byth Street Stafford QLD Australia
BUDDINA QLD 4575 4053
E-mail : [email protected] E-mail : [email protected]
m.au
Telephone : ---- Telephone : +61 7 3243 7222
Facsimile : ---- Facsimile : +61-7-3243 7218
Project : 125 NSC LAKE McDONALD DVE, Page : 1 of 6
COOROY
Order number : ---- Quote number : EB2023ENVADV0001
(EB23ENVADV0001 V2)
C-O-C number : ---- QC Level : NEPM 2013 B3 & ALS QC Standard
Site : ----
Sampler : ANDREW WINTERS
Dates
Date Samples Received : 24-Feb-2024 13:00 Issue Date : 27-Feb-2024
Client Requested Due : 06-Mar-2024 Scheduled Reporting Date : 06-Mar-2024
Date
Delivery Details
Mode of Delivery : Client Drop Off Security Seal : Not Available
No. of coolers/boxes : 5 Temperature : 16°, 16, 16°C - Ice present
Receipt Detail : MEDIUM ESKY No. of samples received / analysed : 102 / 83
General Comments
l This report contains the following information:
- Sample Container(s)/Preservation Non-Compliances
- Summary of Sample(s) and Requested Analysis
- Proactive Holding Time Report
- Requested Deliverables
l Asbestos Identification will be conducted by ALS Melbourne, NATA accreditation no. 825, site no
13778
l SPLIT WORK ORDER: It should be noted that ALS has split this work order with the following work
order EB2406402 due to the size of the sample numbers. For any further information regarding
this processing of samples please contact ALS client services division on
[email protected]
l PLEASE NOTE: Asbestos Identification was not assigned to ALS sample #77 'TP33-2.3, as a 50g
Asbestos ACM/Grab Bag was not received. If you wish to discuss this further please contact ALS
Brisbane Client Services Department at [email protected] PLEASE NOTE: Additional 200g PFAS soil containers were received for ALS samples #12, 27, 52,
77 & 92 were received and added to the workorder, these samples have been placed on hold
until otherwise notified to proceed with analysis. If you wish to discuss this further please contact
ALS Brisbane Client Services Department at [email protected] PLEASE NOTE: ALS #87, Chain Of Custody ID 'TP36-2.3', sample received ID 'TP35-2.3'. Sample
labelled as per Chain Of Custody. If you wish to discuss this further please contact ALS Brisbane
Client Services Department at [email protected] Discounted Package Prices apply only when specific ALS Group Codes ('W', 'S', 'NT' suites) are referenced on COCs.
l Please direct any turn around / technical queries to the laboratory contact designated above.
l Sample Disposal - Aqueous (3 weeks), Solid (2 months ± 1 week) from receipt of samples.
l Analysis will be conducted by ALS Environmental, Brisbane, NATA accreditation no. 825, Site No. 818 (Micro site no. 18958).
l Breaches in recommended extraction / analysis holding times (if any) are displayed overleaf in
the Proactive Holding Time Report table.
l Please be aware that APHA/NEPM recommends water and soil samples be chilled to less than or equal to 6°C for chemical
analysis, and less than or equal to 10°C but unfrozen for Microbiological analysis. Where samples are received above this
temperature, it should be taken into consideration when interpreting results. Refer to ALS EnviroMail 85 for ALS
recommendations of the best practice for chilling samples after sampling and for maintaining a cool temperature during transit.
Document Set ID: 23717062
Version: 0, Version Date: 01/01/1900
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file