Original source · versioned page text
REFERENCE DOCUMENTS - RAL25/0004 (As Published)
Very large file (40.5 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Original PDF page 64, section 1. The text section number identifies this passage in the reader.
GIL
Drinking NEPM PFAS
Units Fresh EPP SWK EPP GWN
Water C HSL’sI NEMPJ
Water E
Nickel ug/L 11 20 11 8M - -
Selenium ug/L - 10 5 5B - -
M
Zinc ug/L 8A 3000F 8A 2.4 - -
TRH C6-C10 ug/L - - - - 1,000 -
TRH C10-C16 ug/L - - - - 1,000 -
TRH C16-C34 ug/L - - - - - -
TRH C34-C40 ug/L - - - - - -
Benzene ug/L 950 1 950 600 800 -
Toluene ug/L - 800 - - - -
Ethylbenzene ug/L - 300 - - - -
ug/L 350 (o-) 600 350 (o-) 200 (o-) - -
Xylenes 200 (p-) 200 (p-) 140 (p-)
Naphthalene ug/L 16 - 16 2.5 - -
Benzo a ug/L - 0.01 - - - -
Pyrene
Phenol ug/L # # 320# 85# - -
OC/OP ug/L # # # # - -
pesticides
PFOS ug/L - - - - - 0.00023J
PFOA ug/L - - - - - 19J
PCB Aroclor ug/L 0.3
1242
PCB Aroclor ug/L 0.01
1254
“-“ = no value given , or value not used/determined in lieu of more applicable alternative value as listed.
A Figure may not protect key species from chronic toxicity.
B Chemical for which possible bioaccumulation and secondary poisoning effects should be considered.
C Provided for assessment of direct contact/accidental ingestion during site redevelopment works and
assessment of potential off-site impacts to registered bores.
D ADWG Table 3.3.2 for estuarine waters, 95% level of protection (or 99% where recommended for
typical slightly-moderately disturbed systems).
E Trigger Values for 95% level of protection (fresh water).
F Aesthetic drinking water value.
125 Lot 105 SP118458 Cooroy DSI 12062024 Rev0 Lot 105 SP118458, Cooroy, QLD, 4563
12/06/2024 60 Detailed Site Contamination Investigation
Document Set ID: 23717062
Version: 0, Version Date: 01/01/1900
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file