Original source · versioned page text
REFERENCE DOCUMENTS - RAL25/0004 (As Published)
Very large file (40.5 MB): the original may take a few minutes to open or download. The page text below is quick to read.
Original PDF page 76, section 1. The text section number identifies this passage in the reader.
Bore Bore Bore stick-up Bore Screened Standing Water Level (mbtoc)
Depth (metres above Interval
(mbgl) ground level) (mBGL) 11/3/24 14/3/24
MB4 25 0.71 5.5-25 0.59 0.06
8.3.2. GROUNDWATER ANALYTICAL RESULTS
All groundwater samples were analysed for dissolved heavy metals (ultra trace), TRH (with silica gel
clean-up), BTEXN, PAH, SVOC, PFAS (super trace short suite) and Total Dissolved Solids. Certificates
of laboratory analysis are presented in Appendix H.
Other than heavy metals and PFAS, no other tested analyte was detected above LOR. A summary of
analytical results for heavy metals and PFAS is presented in Table 19 below, including for sample D1 that
is the field duplicate sample for sample MB4-1.
Table 19 Groundwater Sample Analysis Summary
Compound Units Screening Criteria A MB1-1 MB2-1 MB4-1 D1
14/3/24 14/3/24 14/3/24 14/3/24
Arsenic µg/L 10 <0.2 1.4 <0.2 <0.2
Cadmium µg/L 0.06 <0.05 <0.05 <0.05 <0.05
Total Chromium µg/L NLB <0.2 0.2 0.2 <0.2
Copper µg/L 1.0 4.3 1.1 1.7 0.5
Lead µg/L 1.0 0.1 0.1 <0.1 <0.1
Mercury µg/L 0.06 <0.0004 <0.0004 <0.0004 <0.0004
Nickel µg/L 8 2.6 3.4 0.5 <0.5
Zinc µg/L 2.4 13 15 4 2
PFOS µg/L 0.023 <0.002 <0.002 <0.002 <0.002
PFOA µg/L 19 <0.002 <0.002 <0.002 <0.002
PFBS µg/L none available <0.002 <0.002 <0.002 0.02
Notes:
X Denotes result at or above initial screening SAC
A Most conservative criteria selected as presented in Table 16
B Chromium III criteria has been adopted (No Limit) as the potential for CrVI to be present is expected to
be low to negligible given the site setting and absence of CrVI in speciated soil samples
Copper and zinc exceeded ANZECC 2000 trigger values in all primary samples. In addition, copper and
zinc concentrations in samples MB1-1 and MB4-1 exceeded GIL and EPP Mary River surface water SAC,
but not drinking water criteria.
8.4. LANDFILL GAS
DSI 1 methane field screening results are noted on the borehole logs presented in Appendix G, and were
predominately 0ppm with transitory readings of up to 1ppm within a couple of test pits. Accompanying
carbon dioxide and oxygen concentrations were at expected naturally occurring atmospheric
125 Lot 105 SP118458 Cooroy DSI 12062024 Rev0 Lot 105 SP118458, Cooroy, QLD, 4563
12/06/2024 72 Detailed Site Contamination Investigation
Document Set ID: 23717062
Version: 0, Version Date: 01/01/1900
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.