Council archive · source document
REFERENCE DOCUMENTS - RAL25/0004 (As Published)
Very large file (40.5 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.
Original PDF page 872, section 1. The text section number identifies this passage in the reader.
Page : 3 of 3
Work Order : EB2417075
Client : ENVIRONMENTAL ADVISORS
Project : 125 NSC LAKE McDONALD DVE, COOROY
Method Blank (MB) and Laboratory Control Sample (LCS) Report
The quality control term Method / Laboratory Blank refers to an analyte free matrix to which all reagents are added in the same volumes or proportions as used in standard sample preparation. The purpose of this QC
parameter is to monitor potential laboratory contamination. The quality control term Laboratory Control Sample (LCS) refers to a certified reference material, or a known interference free matrix spiked with target
analytes. The purpose of this QC parameter is to monitor method precision and accuracy independent of sample matrix. Dynamic Recovery Limits are based on statistical evaluation of processed LCS.
Sub-Matrix: SOIL Method Blank (MB) Laboratory Control Spike (LCS) Report
Report Spike Spike Recovery (%) Acceptable Limits (%)
Method: Compound CAS Number LOR Unit Result Concentration LCS Low High
EN33: TCLP Leach - Inorganics/Non-Volatile Organics (Glass Vessel) (QCLot: 5804611)
EN33a-G: Final pH ---- 0.1 pH Unit 5.0 ---- ---- ---- ----
Sub-Matrix: WATER Method Blank (MB) Laboratory Control Spike (LCS) Report
Report Spike Spike Recovery (%) Acceptable Limits (%)
Method: Compound CAS Number LOR Unit Result Concentration LCS Low High
EG005(ED093)C: Leachable Metals by ICPAES (QCLot: 5808898)
EG005C: Copper 7440-50-8 0.1 mg/L <0.1 0.1 mg/L 96.5 87.0 117
EG005C: Lead 7439-92-1 0.1 mg/L <0.1 0.1 mg/L 92.0 85.0 117
EG005C: Nickel 7440-02-0 0.1 mg/L <0.1 0.1 mg/L 94.9 90.0 116
EG005C: Zinc 7440-66-6 0.1 mg/L <0.1 0.1 mg/L 98.8 87.0 122
Matrix Spike (MS) Report
The quality control term Matrix Spike (MS) refers to an intralaboratory split sample spiked with a representative set of target analytes. The purpose of this QC parameter is to monitor potential matrix effects on
analyte recoveries. Static Recovery Limits as per laboratory Data Quality Objectives (DQOs). Ideal recovery ranges stated may be waived in the event of sample matrix interference.
Sub-Matrix: WATER Matrix Spike (MS) Report
Spike SpikeRecovery(%) Acceptable Limits (%)
Laboratory sample ID Sample ID Method: Compound CAS Number Concentration MS Low High
EG005(ED093)C: Leachable Metals by ICPAES (QCLot: 5808898)
EB2416937-002 Anonymous EG005C: Copper 7440-50-8 1 mg/L 104 70.0 130
EG005C: Lead 7439-92-1 1 mg/L 103 70.0 130
EG005C: Nickel 7440-02-0 1 mg/L 95.2 70.0 130
EG005C: Zinc 7440-66-6 1 mg/L # Not 70.0 130
Determined
Document Set ID: 23717062
Version: 0, Version Date: 01/01/1900
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
REFERENCE DOCUMENTS - RAL25/0004 (As Published)Related documentApplication case desk ↗
About this file
- File size
- 40.5 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.