Council archive · source document
REFERENCE DOCUMENTS - RAL25/0004 (As Published)
Very large file (40.5 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.
Original PDF page 956, section 1. The text section number identifies this passage in the reader.
Page : 8 of 9
Work Order : EB2409053
Client : ENVIRONMENTAL ADVISORS
Project : 125 NSC LAKE McDONALD DVE, COOROY
Brief Method Summaries
The analytical procedures used by the Environmental Division have been developed from established internationally recognized procedures such as those published by the US EPA, APHA, AS and NEPM. In house
developed procedures are employed in the absence of documented standards or by client request. The following report provides brief descriptions of the analytical procedures employed for results reported in the
Certificate of Analysis. Sources from which ALS methods have been developed are provided within the Method Descriptions.
Analytical Methods Method Matrix Method Descriptions
Total Dissolved Solids (High Level) EA015H WATER In house: Referenced to APHA 2540C. A gravimetric procedure that determines the amount of `filterable` residue
in an aqueous sample. A well-mixed sample is filtered through a glass fibre filter (1.2um). The filtrate is
evaporated to dryness and dried to constant weight at 180+/-5C. This method is compliant with NEPM Schedule
B(3)
Dissolved Mercury by FIMS - Low Level EG035F-LL WATER In house: Referenced to APHA 3112 Hg - B (Flow-injection (SnCl2)(Cold Vapour generation) AAS) Samples are
0.45µm filtered prior to analysis. FIM-AAS is an automated flameless atomic absorption technique. A
bromate/bromide reagent is used to oxidise any organic mercury compounds in the filtered sample. The ionic
mercury is reduced online to atomic mercury vapour by SnCl2 which is then purged into a heated quartz cell.
Quantification is by comparing absorbance against a calibration curve. This method is compliant with NEPM
Schedule B(3).
Dissolved Metals in Fresh Water -Suite EG094A-F WATER In house: Referenced to APHA 3125; USEPA SW846 - 6020 Samples are 0.45µm filtered prior to analysis. The
A by ORC-ICPMS ORC-ICPMS technique removes interfering species through a series of chemical reactions prior to ion detection.
Ions are passed into a high vacuum mass spectrometer, which separates the analytes based on their distinct
mass to charge ratios prior to measurement by a discrete dynode ion detector. This method is compliant with
NEPM Schedule B(3).
TRH - Total Recoverable Hydrocarbons - EP071SG WATER In house: Referenced to USEPA SW 846 - 8015 Sample extracts are analysed by Capillary GC/FID and
Silica Gel Cleanup quantified against alkane standards over the range C10 - C36. This method is compliant with NEPM Schedule
B(3).
Semivolatile Organic Compounds EP075 WATER In house: Referenced to USEPA SW 846 - 8270 Sample extracts are analysed by Capillary GC/MS and
quantification is by comparison against an established 5 point calibration curve. This method is compliant with
NEPM Schedule B(3)
PAH/Phenols (GC/MS - SIM) EP075(SIM) WATER In house: Referenced to USEPA SW 846 - 8270 Sample extracts are analysed by Capillary GC/MS in SIM Mode
and quantification is by comparison against an established 5 point calibration curve. This method is compliant
with NEPM Schedule B(3)
TRH Volatiles/BTEX EP080 WATER In house: Referenced to USEPA SW 846 - 8260 Water samples are directly purged prior to analysis by Capillary
GC/MS and quantification is by comparison against an established 5 point calibration curve. Alternatively, a
sample is equilibrated in a headspace vial and a portion of the headspace determined by GCMS analysis. This
method is compliant with the QC requirements of NEPM Schedule B(3)
Per- and Polyfluoroalkyl Substances EP231X-LL WATER In-house: Analysis of fresh and saline waters by Solid Phase Extraction (SPE) followed by
(PFAS by LCMSMS LC-Electrospray-MS-MS, Negative Mode using MRM and internal standard quantitation.
Isotopically labelled analogues of target analytes used as internal standards and surrogates are added to the
sample container. The entire contents are transferred to a solid phase extraction (SPE) cartridge. The sample
container is successively rinsed with aliquots of the elution solvent. The eluted extract is concentrated,
combined with an equal volume of reagent water and filtered for analysis. Method procedures and data quality
objectives conform to US DoD QSM 5.4, table B-15 requirements.
Preparation Methods Method Matrix Method Descriptions
Document Set ID: 23717062
Version: 0, Version Date: 01/01/1900
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
REFERENCE DOCUMENTS - RAL25/0004 (As Published)Related documentApplication case desk ↗
About this file
- File size
- 40.5 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.