Council archive · source document
SUPERSEDED Decision Notice - 010.2007.00001841.001 [As Published] · 132007.1841
-4-
16. The development shall be carried out in accordance with the Bushfire Management
Plan prepared by James Warren & Associates Pty Ltd dated November 2007 prepared
for the subject site and the Shire Business Centre site prior to the commencement of
the use.
17. All rainwater tanks located within the 5 metre fire buffer along the site’s southern and
eastern boundaries shall be located underground to ensure unrestricted access through
the fire buffer is maintained.
18. The premises are to be identified by the provision of a street number in a prominent
location to ensure it is identifiable to all persons, particularly emergency services
personnel.
2
19. All Industrial use tenancies shall not be less than 150m use area in size.
20. The proposed development shall have all kitchen, laundry and bathroom fittings that
comply with the AAA Water Conservation Rating System as defined by the AS/NZS
6400 (Water Efficient Products - Rating and Labelling 2003) and AS/NZS 3500
(National Plumbing and Drainage Standard Part 1.2), with toilets to comply with the
AAAA Water Conservation Rating System. All tap ware and shower roses shall not
exceed a maximum flow of 9 litres per min. Dishwashers and washing machines are
excluded from this requirement.
21. All hot water systems installed shall be either solar systems; electric heat pump
systems; or gas systems (LPG or natural).
22. Building K shall remain in common property to allow for research and development
facilities to support the industrial uses over the site, that can be utilised by all tenancies
on the site.
23. Security in the form of a cash bond or trading bank guarantee to the sum of $20,000
must be submitted, to secure performance of all conditions of this approval, prior to the
issue of a Development Permit for Operational Works. The cash bond or trading bank
guarantee will be returned on performance of the conditions of approval less any costs
incurred by Council in respect of enforcing performance of this permit.
24. The requirements of this development approval are to be effected, prior to the use of the
premises. Council reserves the right to call upon the bond or guaranteed sum referred
to in this approval to effect compliance with conditions.
25. The developer must obtain all of the other Development Permits referred to in the
Decision Notice, prior to obtaining a Development Permit for Building Works.
Land Development
Vehicle Access
26. A vehicular access driveway to serve the development shall be constructed from the
Rene Street frontage of the site with a maximum width of 7.0m at the property boundary
and shall be designed and constructed generally in accordance with IPWEAQ drawing
R-0052.
27. The driveway shall be designed and constructed to Council’s design standards and to
grades that prevent vehicles from scraping and/or bottoming whilst also allowing
pedestrians movements along the footpath without any step or level difference. Should
any driveways be constructed to grades that do not comply with AS/NZS 2890.1-2004
and AS2890.2-1989, Council will require that the driveway be removed and
reconstructed to levels that do comply.
Please note, a step between the driveway and the footpath shall be avoided, as it is
preferred to have the footpath continue at a constant grade to minimise the potential for
pedestrians to trip or fall.
Page 4 of 20
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED Decision Notice - 010.2007.00001841.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 94 KB (small file)
- File type
No other editions are linked here.