3.4           Service Station Emission Calculations
3.4.1         Operational Data
Table 3.2 presents a summary of the proposed service station operational data. Figure 3.1 presents
the emission stack and the fugitive source locations.

Table 3.2: Service Station Operating Data

                        Parameter                                                                     Operating Data

                                                                                                         24 Hours a day
                      Operating Hours
                                                                                                         7 days a week

                                                                                                 Maximum 40,000 L / hour
                       Tanker Delivery
                                                                                                 Phase 1 Vapour Recovery

                         Vent Stacks                                                                 Assumed 4.0 m high

                                                                              3 bowser ranks (2 filling points each side) located

               Filling Stations/Petrol Bowsers                                                     below a 4.5 m canopy

                                                                                                 Phase 2 Vapour Recovery

             Service Station Trips Generated1                                           129 (entry and exit), in the peak hour




1   Proposed Service Station, 123 Eumundi – Noosa Road, Noosaville: Traffic Report (October 2015) prepared by Q Traffic
    Engineering Consultants


                                                                                                                                                  Page 12 of 30
                                  Synergy Property Partners Pty Ltd- Air Quality Assessment - Proposed Service Station, 123 Eumundi-Noosa Road, Noosaville
                                                                                                              /Network/Projects/4484/Reporting/4484 Report03.odt

Used in these records

About this file

File size
1.1 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

MCU15_0095 Air Quality Assessment Report.pdf · 1.1 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.