                                  Fuel               Odour                Height
  Stacks/       Emission       Vapour              Emission                Above              Diameter              Velocity
                                                                                                                                         Temp (0C)
  Sources       Sources       Emission                 Rate               Ground                   (m)                 (m/s)
                              Rate (g/s) (OU.m3/s)                            (m)

   Fugitive
                Refuelling,
  emissions
                 spillage
 from bowser                     0.190                   83                     -                     -                   n/a              Ambient
                   and
area – volume
                 whoosh
   source



Table 3.6: Factored Fugitive Emission Rates

                                                              Factored Fugitive Total                              Factored Fugitive
                           Hourly profile
       Hour                                                     VOC Emission Rates                            Odour Emission Rates
                         (% of Throughput)
                                                                                 g/s                                        OU.m3/s

          1                         1.2%                                        0.037                                             16

          2                         0.8%                                        0.025                                             11

          3                         0.6%                                        0.019                                              8

          4                         0.8%                                        0.025                                             11

          5                         1.9%                                        0.059                                             26

          6                         4.6%                                        0.143                                             63

          7                         5.5%                                        0.171                                             75

          8                         5.7%                                        0.177                                             78

          9                         5.5%                                        0.171                                             75

         10                         5.7%                                        0.177                                             78

         11                         6.0%                                        0.187                                             82

         12                         6.0%                                        0.187                                             82

         13                         5.7%                                        0.177                                             78

         14                         5.6%                                        0.174                                             77

         15                         5.9%                                        0.184                                             81




                                                                                                                                               Page 17 of 30
                               Synergy Property Partners Pty Ltd- Air Quality Assessment - Proposed Service Station, 123 Eumundi-Noosa Road, Noosaville
                                                                                                           /Network/Projects/4484/Reporting/4484 Report03.odt

Used in these records

About this file

File size
1.1 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

MCU15_0095 Air Quality Assessment Report.pdf · 1.1 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.