Council archive · source document
Delegated Authority Report Appendix - OPW12 0139 [As Published] · OPW12/0139
3$*( 2)
%5,6%$1(4/' RIWKHUHVSRQVHLVDWWDFKHG
5($6216)255()86$/
1RW$SSOLFDEOH
)857+(5'(9(/230(173(50,765(48,5('
1RW$SSOLFDEOH
$66(660(170$1$*(5&21',7,216
$OO VWUXFWXUHV DVVRFLDWHG ZLWK WKH MHWW\ DQG SRQWRRQ PXVW EH FRQVWUXFWHG ZKROO\ ZLWKLQ
WKHOHDVHDUHD
$OOYHVVHOVEHUWKHGDWWKHMHWW\DQGRU SRQWRRQPXVWEHFRQWDLQHGZKROO\ZLWKLQWKHOHDVH
DUHD
$ULJLGKDQGUDLOPXVWEHILWWHGRQRQHVLGHRIWKHZDONZD\
1R SRVWV RU YHUWLFDO VXSSRUWV RI WKH SURSRVHG MHWW\ DUH WR H[WHQG YHUWLFDOO\ IURP WKH
VWUXFWXUHXQOHVVWKH\SURYLGHVXSSRUWIRUWKHKDQGUDLO
1RERDWOLIWLQJGHYLFHVDUHWREHDWWDFKHGRUPRRUHGDWWKHMHWW\VWUXFWXUHIRUWKHSXUSRVH
RIHOHYDWLQJDYHVVHODERYHWKHZDWHUZLWKRXW&RXQFLODSSURYDO
7KHMHWW\PXVWEHFRQVWUXFWHGLQDPDQQHUWRUHQGHUWKHXQGHUVLGHDUHDYHUPLQSURRI
7KHUHPXVWEHQRHOHFWULFDOUHWLFXODWLRQV\VWHPFDUU\LQJHOHFWULFLW\LQH[FHVVRIYROWV
EH\RQGWKHQRUWKHUQERXQGDU\RI/HDVH3
/LJKWLQJDVVRFLDWHGZLWKWKHXVHPXVWEHGHVLJQHGLQVWDOOHGRSHUDWHGDQGPDLQWDLQHG
LQ DFFRUGDQFH ZLWK 6HFWLRQ RI $6 &RQWURO RI WKH 2EWUXVLYH (IIHFWV RI 2XWGRRU
/LJKWLQJ
%RDWUHSDLUDFWLYLWLHVDUHQRWSHUPLWWHGRQVLWH
:DVWHZDWHUDQGVXOODJHPXVWRQO\EHGLVSRVHGRIDWDSSURYHGSXPSRXWIDFLOLWLHV
7KHPRRULQJIDFLOLW\PXVWQRWEHXWLOLVHGIRUOLYHDERDUGSXUSRVHV
$Q\FRQVWUXFWLRQ DQG SRVW FRQVWUXFWLRQ DFWLYLW\ LV QRW WR LPSDFW RQ WKH FRQGLWLRQRI WKH
ZDWHUZD\DQGLVWREHFRQGXFWHGVRDVQRWWREUHDFKWKH(QYLURQPHQWDO3URWHFWLRQ$FW
(3$ DQGWKH(QYLURQPHQWDO3URWHFWLRQ :DWHU 3ROLF\
3DUNV RU RWKHU SXEOLF ODQG PXVW QRW EH XVHG IRU GHOLYHU\ RU UHPRYLQJ FRQVWUXFWLRQ
HTXLSPHQWDQGPDWHULDOVWRIURPWKHFRQVWUXFWLRQVLWHLQWKHZDWHUZD\ RWKHUWKDQYLDD
SXEOLFERDWUDPS
)0
[OCR of page images]
PAGE 20F3
| BRISBANE QLD 4001 | | of the response is attached. |
| REASONS FOR REFUSAL
Not Applicable
FURTHER DEVELOPMENT PERMITS REQUIRED
Not Applicable
ASSESSMENT MANAGER CONDITIONS
10.
11.
12.
13.
All structures associated with the jetty and pontoon must be constructed wholly within
the lease area.
All vessels berthed at the jetty and/or pontoon must be contained wholly within the lease
area.
A rigid handrail must be fitted on one side of the walkway.
No posts or vertical supports of the proposed jetty are to extend vertically from the
structure unless they provide support for the handrail.
No boatlifting devices are to be attached or moored at the jetty structure for the purpose
of elevating a vessel above the water without Council approval.
The jetty must be constructed in a manner to render the underside area vermin proof.
There must be no electrical reticulation system carrying electricity in excess of 24 volts
beyond the northern boundary of Lease P.
Lighting associated with the use must be designed, installed, operated, and maintained
in accordance with Section 3 of AS4282 Control of the Obtrusive Effects of Outdoor
Lighting.
Boat repair activities are not permitted on site.
Wastewater and sullage must only be disposed of at approved pumpout facilities.
The mooring facility must not be utilised for live-aboard purposes.
Any construction and post construction activity is not to impact on the condition of the
waterway, and is to be conducted so as not to breach the Environmental Protection Act
(EPA) 1994 and the Environmental Protection (Water) Policy 2009.
Parks or other public land must not be used for delivery or removing construction
equipment and materials to / from the construction site in the waterway (other than via a
public boat ramp);
FM1430/1-28/03/2012
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Delegated Authority Report Appendix - OPW12 0139 [As Published].pdfRelated documentApplication case desk ↗
About this file
- File size
- 71 KB (small file)
- File type
No other editions are linked here.