Slope Stability AG-220616-RPT-G-01_[Rev A]

of 32

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Limitations of Report & Notes

       This report is based on information gathered from the field investigation and information
       provided by the client if any. Ground Drill should be notified immediately if ground
       conditions are found to differ from this report.

       Unless otherwise stated this report does not address the following issues;
   •   Mining Subsidence.
   •   Slope Stability (If the site is in a known slip area or is steep, it is recommended that a
       Geotechnical Engineer be engaged to conduct a Slope Stability assessment).
   •   Deep soft or settling soils
   •   Soil Contamination, hazardous materials and or acid sulphate.
   •   Any slopes, dimensions, levels, site features or plans in this report are approximate only
       show approximate testing locations.
   •   Flood levels (It is the client’s responsibility to inform us of any flood levels on the
       allotment).
   •   If water is found in the boreholes this depth may vary greatly over time. This report does not
       address the influence any natural springs may have on the structure.
   •   It is the client’s responsibility to inform us of any nearby underground services that have
       been or will be installed near the proposed area.
   •   Earthworks could affect the design.
   •   If any fill is placed on the allotment post investigation this could change the design.
   •   Surface water is to be diverted away from the area.
   •   This investigation undertaken consisted of the occluded boreholes/test pits, given the size of
       the site it is possible that a problem could have been missed. eg. Filled dam/gully, soft soils,
       fill, springs, boulders, rock etc. We cannot give a definitive assurance that none of these
       problems exist on the site unless we did a greater number of boreholes which would be
       uneconomical and impractical.
   •   Ground Drill will not be liable for any Council Inspection, submission or reviewing fees due
       to changes in report or plan requested by client or Council.
   •   No allowance has been made for spa baths




Authorised Signatory


Matthew Bennett
on behalf of Ground Drill Pty Ltd
QBCC Lic # 15034580
Log in to download the original file

Slope Stability AG-220616-RPT-G-01_[Rev A].pdf · 4.7 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.