‘C) THIS WORK IS COPYRIGHT AND THE PROPERTY OF ROY K. SAINT PTY. LTD. IT MUST NOT BE COPIED, REPRODUCED RETAINED ON OR USED IN ITS ENTIRETY OR IN PARTS FOR ANY PURPOSE OTHER THAN THE SPECIFIC PURPOSE SET OUT HEREON WITHOUT WRITTEN PERMISSION
? 1800 ?
SCREENED AND SECURED COURTYARD™ | ~
TO OWNERS REQUIREMENTS
2780
COURTYARD
70 7 870 70
| __ 1500
|
|
| COURTYARD
|
|
06.06 21.18 SGD ee
70
900.
70
__ 1830
ve om |
a Kitchette
70
2920
21.18 SCD
Entry
o
ms E
70
concrete footpath
—
12.15 Ox
Bedroom 1
robe
robe
1.8m MAX HIGH RETAINING WALL
WITH HANDRAIL _ON TOP
Bedroom 2
4 12.18 OX
18.18 OX
concrete footpath
12.18 OX
|
|
|
ie
of
HIGH RETAINING WALL
1.8m MAX
[EXIT] FINAL LOCATION AND EXTENT OF EXIT SIGNS TO BE DETERMINED
PROPOSED LOWER FLOOR PLAN
Scale 1:100 (43)
DENOTES HARDWIRED SMOKE DETECTOR
INSTALLED TO BCA REQUIREMENTS
DENOTES ILLUMINATED EXIT SIGN TO BCA REQUIREMENTS.
ON SITE BY BUILDER AND ELECTRICIAN
WITH HANDRAIL ON TOP
CONCRETE STAIRS TO BCA REQUIREMENTS
EXTENT TO BE DETERMINED ON SITE
NEW MASONRY RETAINING WALL TO RETAIN
EDGE OF CARPARK CIVIL WORKS — REFER SITE PLAN
FOR DETAILS. Im HIGH HANDRAIL
TO THE TOP OF ALL WALLS
Sra Othe
LY 06 07
ALUMINIUM WINDOWS: Al oluminiem framed mindows ond stiding door
units shall be to AS1288, shall be to matching design and be supplied mith
@ manufacturers quarontee of suitably for the relevant design wind speed.
INTERNAL LININGS: Unless stated othermse, internal linings shall be 10mm
Opprock. Where required, internal timber framed bracing wols shall be
dined with 6mm Hordiflex, Wet orea walls shall be lined with 6mm
Vileboard. Ceiling battens shal be either 50 x 58 FS (or better) pine
or equivalent galvanized stee/ fuming channels, Al to manufacturers
specifications.
ROOFING: Selected Colorbond stee! mith sarking and horizontal bracing to roof
truss manufocturers specifications.
FASCIS AND CUTTERS: Selected matching Colorbond ste! to
monvfocturers specifications,
EXTERNAL WALLS: Unless stated othermse, selected focebrick to AS5700
with approved brick ties installed at 300mm maximum centres at all
Hloor levels and at the 2nd brick course from the top plus at 600mm
max. honzontal and vertical centres in general wall areas. DPC. shall be
built in below each FFL. and wall opening. Weep holes shall be
at 900mm maximum centres ot ot DPC’, Selected waterproof
texture coator concrete render to manuf. spec. to oll extemal surfaces.
ROOF STRUCTURE: Unless stated otherwise, J5 x 70 F8 (or better)
bottens at 900mm maxinum centres fixed to 1/90mm No. 14 Tpe 17
screw (50mm penetration for Joint Group J04 timber) to engineered
root trusses. Trusses shall be at 900mm maximum centres and to
manufacturers specifications.
Doors to sanitary compartments without 1200mm clear
space between the back of the door and the closest
obstacle (such as the toilet bow! or hand basin) must
either open outwards, slide or be readily removable
from the outside.
All concrete slabs and footings shall be to structural
engineer's recommendations and in compliance with
AS2870.
Unless stated otherwise, the owner/s and builder shall
agree as to the location, type and quality of all
fittings, fixtures and finishes prior to commencement.
HANDRAIL & BALUSTRADES
BALUSTRADE POSITIONED MIN 865mm ABOVE NOSING OF TREADS.
1m MIN. ABOVE BALCONY,LANDING OR THE LIKE
OPENING IN BALUSTRADES TO BE CONSTRUCTED SO A 125mm SPHERE
'S NOT PERMITTED TO PASS THROUGH & FOR A STAIR THE SPACE TESTED
IS ABOVE THE NOSING.
ALL STAIRS HANDRAILS & BALUSTRADES TO COMPLY WITH
BCA 1996 PART 3.9.1 & 3.9.2
HORIZONTAL STEEL WIRE
DO NOT USE IF DECK HT EXCEEDS 4.0M FROM FINISHED GROUND LEVEL
125x50mm TOP RAIL WITH SUPPORTS @ 1800c/c MAX.
HORIZONTAL STEEL WIRE RAILS @ 80mm c/c MAX.
DROPPERS @ 600mm c/c MAX
6m MAX. TO EACH TENSIONING POINT.
GAG DESIGN
aint, Consulting
> wlo|o}m
ISSUE |_DATE REVISION
ENGINEERS
ABN. 15 096 410 909
MIEAust CPEng Aust.No.29986
RPEQ No.1476 NPER-3 No.40467
QBSA Lic.No. 16080
1 STANLEY STREET, NAMBOUR QLD. 4560. 4569
PHONE : (07) 54412233 FAX : (07) 54763218
[email protected]
PROPOSED LOWER PLAN
RENOVATION/EXTENSION
at LOT 20 DAVID LOW WAY
PEREGIAN QLD
ror COUMBIS DENTAL SURGERY
HIN OOOOOOOOOO)
prawinc no.|010207-05
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
06/0718 - Approved Plans [As Published]Related documentApplication case desk ↗
About this file
- File size
- 4.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.