(C)_ THIS WORK IS COPYRIGHT AND THE PROPERTY OF ROY K. SAINT PTY. LTD, IT MUST NOT BE COPIED, REPRODUCED RETAINED ON OR USED IN ITS ENTIRETY OR IN PARTS FOR ANY PURPOSE OTHER THAN THE SPECIFIC PURPOSE SET OUT HEREON WITHOUT WRITTEN PERMISSION

 

PROVIDE R2.5 MINIMIN ROOF INSULATION
TO CEILING SPACE TO MANUFACTURERS SPECIFICATIONS

PREFABRICATED TIMBER ROOF TRUSSES @ 900 CTS
TO MANUFACTURERS DESIGN & SPECIFICATIONS

 

 

EXISTING ROOF FRAMING TO BE RETAINED IF POSSIBLE
/ AND NEW ROOF PITCHED OVER TO MANUFACTURERS
DESIGN & SPECIFICATIONS

COLORBOND ROOF SHEETING
TO OWNERS CHOICE

 

 

 

450 EAVE
a REFER FLOOR FRAMING PLAN

 

PROVIDE FIRE RATED CEILING LINING

 

 

 

 

 

 

BETWEEN UPPER AND LOWER AREAS
TO B.C.A. REQUIREMENTS

EXTERNAL CLADDING TO
OWNERS CHOICE

3
a
2
8000 APPROX
MAX 8000 BUILDING HEIGHT NOT TO BE EXCEEDED

 

 

 

 

TT
u

REFER FOOTING PLAN FOR DETAILS

TERMITE PROTECTION

PROVIDE TERMITE PROTECTION IN ACCORDANCE WITH AS 3660.01
— 2000 USING LICENSED CONTRACTOR. INSTALL A “PHYSICAL
BARRIER” TO PERIMETER OF SLAB & TO ALL PENETRATIONS &
PART B SPRAY IN ACCORDANCE WITH AMENDMENT 8 OF BCA.

ATTACHMENTS TO BUILDINGS: ATTACHMENTS TO BUILDING, SUCH AS
DOWNPIPES AND SERVICE PIPES SHALL HAVE A NOMINAL GAP, TO
ALLOW CLEAR AND UNINTERRUPTED INSPECTION ACROSS THE
INSPECTION ZONE.

STRUCTURES SUCH AS STEPS, VERANDAHS, PORCHES, ACCESS
RAMPS, CARPORTS, TRELLISES, DECKS, HOT WATER SYSTEMS, AIR
CONDITIONERS, OR SIMILAR, WHICH ARE NOT PROVIDED WITH ONE OF
THE BARRIER SYSTEMS DESCRIBED IN THE

AS 3660.1-200, SHALL BE SEPARATED FROM THE BUILDING BY A
GAP OF AT LEAST 25mm, TO ALLOW CLEAR AND UNINTERRUPTED
VISUAL INSPECTION ACROSS THE INSPECTION ZONE.

WHERE ATTACHMENTS OR STRUCTURES, AS OUTLINED ABOVE, ABUT
A BUILDING AND THERE IS NO CLEAR GAP, THEN A BARRIER SHALL
BE PROVIDED TO THE ATTACHMENT, REGARDLESS OF THE SIZE OF
THE ATTACHMENT.

BRIDGING AND BREACHING.

BARRIERS SHALL NOT BE BRIDGED BY STRUCTURES, FIXTURES OR
FITTINGS ATTACHED TO THE MAIN BUILDING ( E.G. HOT—WATER
SYSTEMS, STEPS, VERANDAHS ACCESS RAMPS CLADDINGS,
CARPORTS, TRELLISES OR SIMILAR STRUCTURES), NOR SHALL THEY
BE BREACHED BY THE INSTALLATION OF SERVICE ENTRY POINTS,
DOWN PIPES, AN ADDITIONAL SLAB, PATHWAYS, LANDSCAPING,
GARDENING, OR SIMILAR, UNLESS ADDITIONAL BARRIERS ARE USED
TO DETER CONCEALED ACCESS BY TERMITES TO THE STRUCTURE.

TYPICAL SECTION

Scale |: 100 (A3)

600
900
1050 |
1200 |
1350
1500
1800
2100
2400

| 310
460

535
615
690
765
920
1070
1225

 

 

 

SHADE WIDTHS for
OPENINGS
Aresuyl Arflusy

U.0b.01.

CONTRACTOR TO CONFIRM ALL DIMENSIONS &
LEVELS ON SITE PRIOR TO COMMENCEMENT
OF ANY WORK.

ALL CONSTRUCTION TO COMPLY WITH THE
AUSTRALIAN BUILDING CODE REQUIREMENTS
& RELEVANT AUSTRALIAN STANDARDS.

STAIRS & BALUS{RADES

1, STAIRS SHALL BE CONSTRUCTED TO THE REQUIREMENTS OF BCA PART
3.9.1

2. STAIRS SHALL HAVE A MAXIMUM RISE OF 190mm, MINIMUM GOING OF 240
AND WITH A SLOPE RELATIONSHIP (2R+G) OF 550min. TO 700max.

3. TREADS AND BALUSTRADES MUST BE CAPABLE OF ALLOWING A 1259
SPHERE THROUGH OPENINGS.

4. BALUSTRADES TO STAIRS MUST NOT BE LESS THAN 865mm HT. MEASURED
FROM THE STEP NOSINGS, AND 100mm HT. AT
LANDINGS OR BALCONIES.

90x70 F.11 HANDRAIL

DOWEL BALUSTERS
TO MATCH EXISTING
AT 125mm MAX. CTS

 

90x90 F.11 END AND
INTERMEDIATE
POSTS

 

      

250x50 F.14 UNSEAS.
TIMBER STRINGER 15mm.
MAX. HOUSING FOR TIMBER
TREADS

TYPICAL GOING

Le. | J

TYPICAL TIMBER STAIR DETAIL

NOTE: -

ALL BALUSTRADING SHALL BE IN ACCORDANCE WITH THE B.C.A CLAUSE 02.16 &
02.17, ALL STAIRS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE B.C.A
CLAUSES D2.13 - 02.15. TIMBER ELEMENTS SHALL BE IN ACCORDANCE WITH
A.S.C.M SECTION D65.12.

RISER AND GOING DIMENSIONS <n

 

 

 

 

 

 

RISER CONG QUANTITY ARG
MAK MN MAK MN MAK MN
PRLC STARS i 9% BO KO HO
PRIVATE StAses: 6 0 KOH
: ayaa
3
Note: Wo PRIVATE STAIRS ARE-

@ STAIRS IN A CLASS 1 OR 10 BUILDING

4) STAIRS IN A SOLE-OCCUPANCY UMIt IN A CLASS 2 BUILDING OR CLASS 4 PARK AND
41D IN ANY BULDING. STAIRS WHICH ARIE NOt PART OF A REQUIRED EXit AND 10 WHICH THE
PUBLIC DO NOt NORMALLY HAVE ACCESS,

) THE GOING IN TAPERED READS «AS IN A CURVED OR SPIRAL STAIR? IS MEASURED -
@ 270mm IN FROM THE OUTER SIDE IF THE FLIGHT IS LESS THAN IM WIDE:

> 270mm PROM BACH SIDE IF THE PLIGHT IS IM OR MORE WIDE. AND MUST BE NOt LESS THAN
See At {HE HARROW END.

90x45 F.11
BOTTOM RAIL

250x75 F.14 UNSEAS. STAIR
TREADS MAX. 1400mm SPAN

 

 

GAG DESIGN

 

 

 

 

 

>|wlo}o|m

 

 

 

 

DATE |

D
a
ic
m

REVISION

 

 

 

 

    

ENGINEERS
ABN. 15 096 410 909

aint, Consulting

AL, HYDRAULI TYPICAL SECTION

: RENOVATION/EXTENSION

at LOT 20 DAVID LOW WAY
PEREGIAN QLD

ror COUMBIS DENTAL SURGERY

MiEAust CPEng Aust.No.29986

RPEQ No.1476 NPER-3 No.40467

QBSA Lic.No. 16080

1 STANLEY STREET, NAMBOUR QLD. 4560. 4564
PHONE : (07) 54412233 FAX : (07) 54763218
[email protected]

 

1:100 (A3) ISSUE PRINTED: CAD001

 

DRAWING NO

 

 

T= OOOODOOOOO

010207-07 5

 

 

Used in these records

About this file

File size
4.4 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

06_0718 - Approved Plans [As Published].pdf · 4.4 MB (large file)