06/0718 - Approved Plans [As Published] · 132006.718
Plans and drawings: the text below has words only, no drawings.
(C)_ THIS WORK IS COPYRIGHT AND THE PROPERTY OF ROY K. SAINT PTY. LTD, IT MUST NOT BE COPIED, REPRODUCED RETAINED ON OR USED IN ITS ENTIRETY OR IN PARTS FOR ANY PURPOSE OTHER THAN THE SPECIFIC PURPOSE SET OUT HEREON WITHOUT WRITTEN PERMISSION
PROVIDE R2.5 MINIMIN ROOF INSULATION
TO CEILING SPACE TO MANUFACTURERS SPECIFICATIONS
PREFABRICATED TIMBER ROOF TRUSSES @ 900 CTS
TO MANUFACTURERS DESIGN & SPECIFICATIONS
EXISTING ROOF FRAMING TO BE RETAINED IF POSSIBLE
/ AND NEW ROOF PITCHED OVER TO MANUFACTURERS
DESIGN & SPECIFICATIONS
COLORBOND ROOF SHEETING
TO OWNERS CHOICE
450 EAVE
a REFER FLOOR FRAMING PLAN
PROVIDE FIRE RATED CEILING LINING
BETWEEN UPPER AND LOWER AREAS
TO B.C.A. REQUIREMENTS
EXTERNAL CLADDING TO
OWNERS CHOICE
3
a
2
8000 APPROX
MAX 8000 BUILDING HEIGHT NOT TO BE EXCEEDED
TT
u
REFER FOOTING PLAN FOR DETAILS
TERMITE PROTECTION
PROVIDE TERMITE PROTECTION IN ACCORDANCE WITH AS 3660.01
— 2000 USING LICENSED CONTRACTOR. INSTALL A “PHYSICAL
BARRIER” TO PERIMETER OF SLAB & TO ALL PENETRATIONS &
PART B SPRAY IN ACCORDANCE WITH AMENDMENT 8 OF BCA.
ATTACHMENTS TO BUILDINGS: ATTACHMENTS TO BUILDING, SUCH AS
DOWNPIPES AND SERVICE PIPES SHALL HAVE A NOMINAL GAP, TO
ALLOW CLEAR AND UNINTERRUPTED INSPECTION ACROSS THE
INSPECTION ZONE.
STRUCTURES SUCH AS STEPS, VERANDAHS, PORCHES, ACCESS
RAMPS, CARPORTS, TRELLISES, DECKS, HOT WATER SYSTEMS, AIR
CONDITIONERS, OR SIMILAR, WHICH ARE NOT PROVIDED WITH ONE OF
THE BARRIER SYSTEMS DESCRIBED IN THE
AS 3660.1-200, SHALL BE SEPARATED FROM THE BUILDING BY A
GAP OF AT LEAST 25mm, TO ALLOW CLEAR AND UNINTERRUPTED
VISUAL INSPECTION ACROSS THE INSPECTION ZONE.
WHERE ATTACHMENTS OR STRUCTURES, AS OUTLINED ABOVE, ABUT
A BUILDING AND THERE IS NO CLEAR GAP, THEN A BARRIER SHALL
BE PROVIDED TO THE ATTACHMENT, REGARDLESS OF THE SIZE OF
THE ATTACHMENT.
BRIDGING AND BREACHING.
BARRIERS SHALL NOT BE BRIDGED BY STRUCTURES, FIXTURES OR
FITTINGS ATTACHED TO THE MAIN BUILDING ( E.G. HOT—WATER
SYSTEMS, STEPS, VERANDAHS ACCESS RAMPS CLADDINGS,
CARPORTS, TRELLISES OR SIMILAR STRUCTURES), NOR SHALL THEY
BE BREACHED BY THE INSTALLATION OF SERVICE ENTRY POINTS,
DOWN PIPES, AN ADDITIONAL SLAB, PATHWAYS, LANDSCAPING,
GARDENING, OR SIMILAR, UNLESS ADDITIONAL BARRIERS ARE USED
TO DETER CONCEALED ACCESS BY TERMITES TO THE STRUCTURE.
TYPICAL SECTION
Scale |: 100 (A3)
600
900
1050 |
1200 |
1350
1500
1800
2100
2400
| 310
460
535
615
690
765
920
1070
1225
SHADE WIDTHS for
OPENINGS
Aresuyl Arflusy
U.0b.01.
CONTRACTOR TO CONFIRM ALL DIMENSIONS &
LEVELS ON SITE PRIOR TO COMMENCEMENT
OF ANY WORK.
ALL CONSTRUCTION TO COMPLY WITH THE
AUSTRALIAN BUILDING CODE REQUIREMENTS
& RELEVANT AUSTRALIAN STANDARDS.
STAIRS & BALUS{RADES
1, STAIRS SHALL BE CONSTRUCTED TO THE REQUIREMENTS OF BCA PART
3.9.1
2. STAIRS SHALL HAVE A MAXIMUM RISE OF 190mm, MINIMUM GOING OF 240
AND WITH A SLOPE RELATIONSHIP (2R+G) OF 550min. TO 700max.
3. TREADS AND BALUSTRADES MUST BE CAPABLE OF ALLOWING A 1259
SPHERE THROUGH OPENINGS.
4. BALUSTRADES TO STAIRS MUST NOT BE LESS THAN 865mm HT. MEASURED
FROM THE STEP NOSINGS, AND 100mm HT. AT
LANDINGS OR BALCONIES.
90x70 F.11 HANDRAIL
DOWEL BALUSTERS
TO MATCH EXISTING
AT 125mm MAX. CTS
90x90 F.11 END AND
INTERMEDIATE
POSTS
250x50 F.14 UNSEAS.
TIMBER STRINGER 15mm.
MAX. HOUSING FOR TIMBER
TREADS
TYPICAL GOING
Le. | J
TYPICAL TIMBER STAIR DETAIL
NOTE: -
ALL BALUSTRADING SHALL BE IN ACCORDANCE WITH THE B.C.A CLAUSE 02.16 &
02.17, ALL STAIRS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE B.C.A
CLAUSES D2.13 - 02.15. TIMBER ELEMENTS SHALL BE IN ACCORDANCE WITH
A.S.C.M SECTION D65.12.
RISER AND GOING DIMENSIONS <n
RISER CONG QUANTITY ARG
MAK MN MAK MN MAK MN
PRLC STARS i 9% BO KO HO
PRIVATE StAses: 6 0 KOH
: ayaa
3
Note: Wo PRIVATE STAIRS ARE-
@ STAIRS IN A CLASS 1 OR 10 BUILDING
4) STAIRS IN A SOLE-OCCUPANCY UMIt IN A CLASS 2 BUILDING OR CLASS 4 PARK AND
41D IN ANY BULDING. STAIRS WHICH ARIE NOt PART OF A REQUIRED EXit AND 10 WHICH THE
PUBLIC DO NOt NORMALLY HAVE ACCESS,
) THE GOING IN TAPERED READS «AS IN A CURVED OR SPIRAL STAIR? IS MEASURED -
@ 270mm IN FROM THE OUTER SIDE IF THE FLIGHT IS LESS THAN IM WIDE:
> 270mm PROM BACH SIDE IF THE PLIGHT IS IM OR MORE WIDE. AND MUST BE NOt LESS THAN
See At {HE HARROW END.
90x45 F.11
BOTTOM RAIL
250x75 F.14 UNSEAS. STAIR
TREADS MAX. 1400mm SPAN
GAG DESIGN
>|wlo}o|m
DATE |
D
a
ic
m
REVISION
ENGINEERS
ABN. 15 096 410 909
aint, Consulting
AL, HYDRAULI TYPICAL SECTION
: RENOVATION/EXTENSION
at LOT 20 DAVID LOW WAY
PEREGIAN QLD
ror COUMBIS DENTAL SURGERY
MiEAust CPEng Aust.No.29986
RPEQ No.1476 NPER-3 No.40467
QBSA Lic.No. 16080
1 STANLEY STREET, NAMBOUR QLD. 4560. 4564
PHONE : (07) 54412233 FAX : (07) 54763218
[email protected]
1:100 (A3) ISSUE PRINTED: CAD001
DRAWING NO
T= OOOODOOOOO
010207-07 5
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
06/0718 - Approved Plans [As Published]Related documentApplication case desk ↗
About this file
- File size
- 4.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.