Attachment 4 - Site Investigation and Slab Report
If > 1800 mm wide,
consider providing
articulation joints
both sides of window
If > 1800 mm wide,
consider providing
articulation joints
both sides of window
Figure 11 Articulation joint
Joint extends
Figure 10 through window
Alternative sill
Figures 12,13
Figure 10
Articulation joint Alternative
Figures 12,13
Maximum spacing Spacing, see Section 5
from Table 2
(a)
Articulation joint
Spacing, see Section 5 Maximum spacing
(a) from Table 2
If > 1800 mm wide,
consider providing
articulation joints
both sides of window
Articulation joint
(b)
Figure 8 Articulation joint at window openings with Min. 600
masonry between
Spacing, see Section 5 Maximum spacing
(a) Offsetting joint may simplify detail at lintel from Table 2
(b)
(b) Positioning of openings to line up may simplify
location of joints and reduce visual impact Figure 9 Articulation joints at window openings
that are offset
(a) Joint adjacent to lower opening
(b) Joint adjacent to higher opening
Articulated Walling Page 9