alternative means to mechanical pumping used to
achieve such immunity.
Major Electricity Infrastructure & Substations AO18.1 Not Applicable
PO18 Development including any sensitive land
Development is sufficiently separated from major uses is at least:
electricity infrastructure and substations to minimise
the likelihood of nuisance or complaint. a) 50 metres from a
transmission substation;
b) 10 metres from any
other substation; and
c) 30 metres from a transmission line
easement.
AO18.2
Habitable buildings are not located within an
easement for a distribution line.
PO19 AO19 Not Applicable
Development is located and designed to avoid or Noise emissions do not exceed 5db(A) above
minimise noise nuisance from the use of background noise level internal to a
infrastructure. habitable building measured in accordance
with AS1055.
PO20 AO20 Not Applicable
Wherever practicable habitable buildings are Where adjoining substations or major
orientated to avoid direct overlooking of major electricity infrastructure, habitable buildings
electricity infrastructure or substations. are orientated so that the majority of outdoor
living areas and windows of habitable rooms
face away from the infrastructure.
Earthworks and Drainage AO21 Not Applicable
PO21 Filling other than accessways: No fill proposed
Earthworks and drainage operational works do not
directly, indirectly or cumulatively cause adverse a) does not extend more than the
impacts external to the development site by: equivalent of 3 metres around the
main building, measured from the
a) causing ponding of water on the site or near outer walls of the building;
by land; b) is limited to a maximum of 500m2;
b) increasing flooding, which adversely affects and
the safety or use of any land upstream and c) does not impact on the local
downstream; drainage of adjoining properties.
c) adversely affecting the flow of water in any
overland flow path; and
d) adversely affecting the privacy or visual am
enity of surrounding property.
Editor's Note—Development should ensure that filling
does not impact on the amenity and usability of
neighbouring properties (including loss of privacy
caused by relative level changes) or offsite drainage.
Landslide Hazard Area AO22.1 Not Applicable
PO22 Development, including associated access, is No new construction in areas identified as
Development maintains the safety of people, property not located on land identified as a landslide Landslide effected.
and hazardous materials stored in bulk from the risk of hazard area on a Landslide Hazard Overlay
landslide. Map.
AO22.2
Development, including associated access, is
located outside moderate, high and very high
landslide hazard areas and areas with
15% slope or greater, as determined by a site-
specific slope-analysis.
Editor's Note—A site- specific geotechnical
assessment may be used to demonstrate that
although the proposed development is shown
on the Landslide Hazard Overlay as being in
the moderate, high or very high landslide
hazard area, the landslide risk is low or very
low.
AO22.3
A site-specific geotechnical assessment is
Planning Partnerships
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Attachment F - Town Planning Submission.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.1 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.