Council archive · source document
Council Decision - Minor Change - MCU13 0081 03 [As Published] · MCU13/0081.03
Plan No. Rev. Plan/Document Name Date
SD20.00 Q Prepared by Spout Architects - New Works 29.11.2022
Ground Floor
SD20.01 N Prepared by Spout Architects - New Works 29.11.2022
First Floor
SD30.00 L Prepared by Spout Architects - New Works 29.11.2022
Elevations
SD30.01 L Prepared by Spout Architects - New Works 29.11.2022
Elevations
SD60.10 D Prepared by Spout Architects - Detailed 29.11.2022
area – stage 2 – tenancies 3,4 & 5
SD60.11 B Detailed Area – Stage 2 – Tenancies 3, 4 29.11.2022
and 5 (Perspectives)
Amendments The new feature awnings are to be setback a minimum of 2 metres
from the Park Road frontage. All timber batten screens and support
posts are to be setback a minimum of 2 metres from all street
frontages.
The bulk of the new feature awnings and associated pillars/batten
screens to be reduced by:
• Lessening the thickness of the feature awnings and pillar/batten
screens, including the use of lightweight building materials.
• The feature awnings and pillars/batten screens must be made of
light-coloured materials that complement the beachside
character.
Performance Bond
11. Security in the form of a cash bond or trading bank guarantee to the sum of $25,000 must
be submitted to Council, to secure performance of all conditions of this approval, prior to the
issue of a Development Permit for Building Works. The cash bond or trading bank guarantee
will be returned on performance of the conditions of approval less any costs incurred by
Council in respect of enforcing performance of this permit. Council reserves the right to call
upon the bond or guaranteed sum to effect compliance with conditions.
Nature and Extent of Approved Use
12. The roofed outdoor dining area associated with Lot 7 (The Providore) must remain
unenclosed and is limited to a maximum of 56m2 use area.
13. No structures are approved by this development approval within The Parade, on public land.
Roof Terrace Pergolas
14. Pergolas on the roof terraces must be:
a. setback in line with the existing roof exhaust ducts for each unit’s roof terrace;
b. a maximum of 9m2 in area; and
c. a maximum of 2.5m in height but not exceeding the proposed roof exhaust ducts
structure height as shown on the Approved Plans.
Page 5 of 10
Document Set ID: 22821337
Version: 5, Version Date: 23/02/2024
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Council Decision - Minor Change - MCU13 0081 03 [As Published].pdfRelated documentApplication case desk ↗
About this file
- File size
- 179 KB (small file)
- File type
No other editions are linked here.