24.002_Wyuna Dr_Issue F_27Aug24
notes
1. Survey information to be confirmed by Licensed
Surveyor prior to construction. Where property
boundary locations are not clear, the contractor shall
organise an identification survey to locate required
boundaries .
2. Extent of site earthworks to be confirmed by
engineer &/or contractor on site prior to construction.
3. Contractor to confirm siting & orientation prior to
setout. Location of pontoon & pontoon setout to be
carried out by Licensed Surveyor.
4. All services to be located on site by contractor prior
to construction.
24000 5. Do not scale off drawings, use figured dimensions
only. Any dimensions not nominated must be referred to
the Designer for confirmation. Contractor shall verify all
dimensions on site prior to construction.
boundary
Projected property details
Navigation co
boundary
allocation
No. 33 Wyuna Drive
00 w ater Noosaville QLD 4566
15
we y b a
15000
8.625m
Noosa Shire Council
22°12'22"
rridor
Locality - Noosaville
Lot 16 on N10576
30.724m Existing pontoon &
Site Area - 614m²
catwalk to be removed Site Coverage - N/A
by others
16688
114°16'42"
Zone - Low Density Residential
Overlays - Acid Sulphate Soils
- Flood Hazard
8.619m
- Riparian Buffer
pool water allocation area
wy u n a
fish habitat
8.0 x 3.5m area
10.324m
294°47'42"
max berthing size
14516
14500 from centre of jetty
c ree k
rl 2.70 rl 1.35
118°18'42"
8.620m
terrace
proposed
drive
7150
3.830m 122°24'42"
jetty
299°57'42"
3650
1500 water allocation boundary
30.685m 212°32'02" Projected boundary
14192
signatures
owner/s
site plan
1 1 : 200
builder
DESIGNER CHECKER WIND CATEGORY CLIENT PROJECT DRAWING NAME SHEET NO REV PROJECT NO
No 13 GODWIN PLACE . PELICAN WATERS . QLD . 4551 SDK SDK N3 SPIAGGIA INVEST P/L, VISTA BLU P/L, NEW JETTY SITE PLAN 01 F 24.002 A3
NORTH
0409 612 231 | WWW.KUNKELBUILDINGDESIGN.COM.AU
QBCC Lic No 1136721 REV DATE DRAWN ISSUE TROPICALE INVEST P/L & PARADISO INVEST P/L No. 33 WYUNA DRIVE, NOOSAVILLE Q 4566 SHEETS IN SET SCALE
F 27/08/24 SDK CONSTRUCTION ISSUE Lot 16 ON N10576 2 1 : 200
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Any dimensions not nominated must be referred to the Designer for confirmation. The information contained within this document is the copyright of the Designer. Use or copying in whole or part without the written permission of the Designer constitutes an infringement of copyright. Minimum Design Standards: To be in accordance with current National Construction Code (NCC), Queensland Development Code (QDC), AS/NZS Standards, Building Regulations, Local Government Planning Scheme & Policies