GENERAL COMMITTEE MEETING AGENDA                                                   16 AUGUST 2021


2.2. Site Description
The site comprises two parcels of land (Lot 30 SP170751 & Lot 1 SP228052) both known as 115
Eumundi Noosa Road. The smaller 5,014m2 vacant parcel of land, Lot 30 SP170751, is used for the
new staff car park. The larger 56,755.06m2 parcel of land contains the existing Good Shepard
Lutheran College school development. The proposed additional demountable buildings are
proposed on the larger lot.
2.3. Surrounding Land Uses
The site is surrounded by industrial, residential, community and open space recreation land uses.
3.         ASSESSMENT
3.1. Instruments for Statutory Assessment
Under the Planning Act 2016 the application must be assessed against each of the following
statutory planning instruments to the extent they are relevant to the development:
        State Planning Policy;
        South East Queensland Regional Plan;
        Planning Regulation 2017;
        Noosa Plan 2020.
The following codes from the Noosa Plan are applicable to this development:
        Noosaville Local Plan Code
        Community Facilities Zone Code
        Community Activities Code
        Works Codes
The subject site is located in the Noosaville Locality and is zoned Community Facilities. The
proposed use is identified as a consistent use within the zone and is required to follow a code
assessable application process.
The application has been found to generally comply with all applicable statutory instruments. The
pertinent issues arising out of the assessment are discussed below:

     Criteria                     Planning Scheme               Proposal               Complies

     Site Area                    N/A                           56,755.06m²
                                                                5,014m²

     Gross floor area             Individual buildings to not   Approx. 290m2          
                                  exceed 1,000m²

     Site cover                   50% max                       Approx. 43 %           

     Landscaped open space 15% min                              >15%                   

     Building height
          storeys                2 storeys max                 1 storey               
          metres                 8 metres                      Approx. 4 metres       


                                                                                     Page 12 of 92
Log in to download the original file

2021-08-16 General Committee Meeting Agenda(PDF, 8MB).pdf · 8.3 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.