38 ELANDA STREET,

PROPOSED DUPLEX

AT

SUNSHINE BEACH QLD 4567

FOR:- GEOFF CONNAN

 

DRAWING REGISTER

 

DRAWING

DESCRIPTION

REVISION

 

NUMBER

 

 

 

 

 

 

 

 

 

 

 

 

COVER PAGE P2
S2 FOOTING PLAN Pl
33 FIRST FLOOR FRAMING PLAN
S4 ROOF FRAMING PLAN # DETAILS
S5 MEMBERS SCHEDULE # DETAILS
S6 GROUND FLOOR BRACING PLAN
ST FIRST FLOOR BRACING PLAN
S8 DETAILS
S94 DETAILS
slo DETAILS
Sl GENERAL NOTES ¢ CONCRETE NOTES
s|2 BRACING & TIEDOWN DETAILS
S|3 APPENDIX A € B

 

 

 

 

 

 

 

 

 

 

 

 

 

WATERPROOFING OF WALLS AND SLABS IS

 

 

TO BE TO THE BUILDERS SPECIFICATIONS, LEGEND
IUNO UNLESS NOTED OTHERWISE
ax agin
MIN MINIMUM
N ves HORIZONTAL
VERTICAL
DO OT SUBSTITUTE REINF'T REINFORCEMENT
IHD HOLD DOWN
ALTERNATIVE TIMBER HD HOLD DOHN gL
TYPES OR SIZES WITHOUT FSW FULL STRENGTH BUTT WELD
CB
ENGINEERS WRITTEN NTS Norro Scare EAS
APPROVAL U/S UNDERSIDE

 

 

 

 

 

 

 

 

PETER RIENECKER - RPEQ 2088

This drawing is not to be copied or amended without written
permission fram Rienmoc Consulting Engineers

NOTES

 

|. REFER TO APPENDIX A FOR SITE DRAINAGE
REQUIREMENTS AND APPENDIX B FOR SITE
PREPARATION € EARTHWORKS DETAILS.

2. THE MINIMUM ALLOWABLE BEARING CAPACITY AT
UNDERSIDE OF FOOTING BEAMS SHALL BE l00kPa,
UNLESS NOTED OTHERWISE.

3. THE ENGINEER IS TO BE NOTIFIED IF VARIATION
OCCURS BETWEEN SOIL CONDITIONS DURING
CONSTRUCTION AND THAT NOTED ON BORELOGS,
ADVISE ENGINEER IF ROCK IS ENCOUNTERED IN
FOOTING EXCAVATIONS.

4. SLABS TO BE CAST ON 50mm (420mm) LAYER
OF COARSE SAND.

5, MEMBRANE TO BE 0.2mm POLYTHENE (or
EQUIVALENT) LAPPED 200 AT JOINTS, CARRY
DOWN 200mm DOWN FACES DEEP BEAMS,

6. ALL REINFORCEMENT TO BE IN ACCORDANCE WITH
ASI302 AND ASI304,

7. ALL CONCRETE WORK TO BE IN ACCORDANCE WITH
AS53600, Fic = 25MPa,

8. ALTERATION TO SITE CONDITIONS AFTER THE
HOUSE IS COMPLETED BY WAY OF LANDSCAPING,
HOUSE EXTENSIONS OR TREE REMOVAL CAN
EFFECT THE STABILITY OF THE FLOOR SLAB.
THE OWNER SHALL REFER TO THE BUILDER
BEFORE MAKING SUCH CHANGES,

9, WHERE BRITTLE FLOOR COVERINGS (TILES, ETC)
ARE TO BE USED. SLAB MESH IS TO BE
INCREASE TO F942 FOR THE AFFECTED AREA OR
DELAY FOR MINIMUM OF THREE (3) MONTHS THE
PLACEMENT OF THE FLOOR COVERINGS.

RIENMAC eryit

A.BN. 52 010 666 430 A.C.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:

SUITE 5, FIRST FLOOR, P:- (07) 5478 250

   

SAINT CIRINO, (07) 5444 |I5q
137 BRISBANE ROAD, Email: info@rienmac. biz|
(PO BOX 149) info@rienmac,ne'

MOOLOOLABA QLD 4557
CLIENT:
GEOFF CONNAN

PROJECT:

PROPOSED DUPLEX

Web:— www ,rienmac, bi:

 

38 ELANDA STREET
SUNSHINE BEACH @LD 4567

REAL PROPERTY DESCRIPTION ¢ COUNCIL:
LOT 158

COUNTY OF MARCH, PARISH OF WEYBA
NOOSA SHIRE COUNCIL
DRAWING TITLE:

COVER SHEET

 

Designed: PLR = Drawn: LR
SCALES:

Engineer: PLR |DATE:

16436 S|| P2

JOB NUMBER DWG No, | ISSUE

 

 

I5 NOV l6é

 

 

 

 

 

DO NOT SCALE OFF DRAWINGS. | AS

SHEET | OF 13 |CHECKED: PLR

 

 

 

 
Full text of the other 12 pages

Page 2

NOTE: APPROX 800mm OF LOOSE SAND HAS BEEN FOUND ON THIS SITE, THIS MATERIAL IS TO
BE EXCAVATED AND REPLACED AND COMPACTED IN LAYERS TO A MINIMUM UNIFORM DENSITY
OF 98% COMPACTION. ALL FOOTINGS ARE THEN TO BE FOUNDED IN MATERIALS OF MINIMUM SAFE
BEARING CAPACITY l00kPa, ANY FILL MATERIAL BENEATH SLAB IS TO BE COMPACTED IN
LAYERS TO A MINIMUM UNIFORM DENSITY OF 98% STANDARD COMPACTION.

100 SLAB ON GROUND TO DRIVEWAY.

CROSSOVER TO BE IN | LAYER F72 MESH 30 TOP COVER,

ACCORDANCE WITH COUNCIL
SPECIFICATIONS 125 SLAB.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

| PFI | [| [] [| [] [00 SLAB ON GROUND TO EXTERNAL AREAS.
| LAYER F72 MESH 30 TOOP COVER.
7 L EB
| : | LIU -
7
2 es
ooogo =P :
P| PFI | PFI P ] all | I | Pel |
E CTT —— a oO Oo
Y TT 7 a a
fq | =| | | & FBI | | |
a —— | | | 4506 MASS CONCRETE PIERS
| | | bop att | | ty | | MIN 300 PAST U/S OD POOL °
tT | |_| owes WJ [— EXCAVATION.
a _ _ ex ® a 0
Ti — Tr T 7 pS — HI 2 Oe ae I | © _ | |
- _ _ N Ors < K
[ abe = IE = Fle gp RRR ql | | |
la WAS AP TOI AY, e zl | | |
v a) | — 4K — eC FBI |
e eI — | | | ofl ia ofl
| |] I HII | | |F-—-7 i a of — ==>
d
| J —_— I a ee a ee ee
Aes ZY VA
Jj | Tr 2 ia SS Top fe Te MRSS Ses Kay COT SY
° il if I | ee lee
| al ff = Jp = I || | a wy
HH = ae yl, | | | yo
ot ti aE x ale al | | 2 we
Al a { — Jo qr 4! | | |
| | I | | | | 1 pRo---Tn 4
| | | i Ji al EB
| — | |
| I EB IE Fel | | Pel
BL 4 |i 0
| | FF | pay -— ic all | | = |"
B In ir |
| | Le ee |
| P -| HOO Oo
FBI EB
|
| Pr | LIU

FOUNDATION DESIGN IS BASED ON REPORT No. 16/0258 BY GLOBAL TESTING PTY LTD.
REFER TO THIS REPORT FOR SOIL CONDITIONS EXPECTED ON SITE. IF ACTUAL SOIL
CONDITIONS VARY SIGNIFICANTLY FROM THOSE IN THE REPORT. CONTACT ENGINEER FOR
RE-APPRAISAL OF FOOTING DESIGN,

EXCAVATION FOR POOL SHALL NOT EXTEND BELOW A LINE DIPPING
AT 45° AWAY FROM THE NEAREST UNDERSIDE CORNER OF ANY
FOOTINGS. CONTACT ENGINEER IF UNCERTAIN.

CONFIRM ALL STEPS AND FALLS WITH ARCHITECTS DRAWINGS.
BUILDER TO VERIFY LOCATION OF ALL SERVICES ON SITE

 

 

 

 

 

 

 

 

CJ - FULL HEIGHT CONTROL JOINT TO MASONRY. PRIOR TO ORDERING MATERIALS OR COMMENCING WORK.
FOOT | NG PLAN LOCATION OF POOL TO BE VERIFIED ON SITE.
A.B.N, 52 010 666 430 | CIENT: Designed: PLR|SCALES: 1:100
RIENMAC prvttp EN O10 Gee 430 | GEOFF CONNAN 7
PROJECT: Engineer: PLR|DRAWN: LR |DATE: 15 NOV |é
CONSULTING CIVIL € STRUCTURAL ENGINEERS ERCP OSED QUE EX
SUNSHINE COAST OFFICE: LOT 156
SUITE 5, FIRST FLOOR, SAINT CIRINO, 137 BRISBANE ROAD, | SUNSHINE BEACH QLD 4567 COUNTY OF MARCH PARISH OF WEYBA 16436 5S? Pl
(PO BOX 149) MOOLOOLABA @LD 4557 DRAWING TITLE: NOOSA SHIRE COUNCIL
Phone:- (07) 5478 2500 Fax:- (07) 5444 |I58 FOOTING PLAN REAL PROPERTY DESCRIPTION ¢ COUNCIL: JOB _NUMBER DWG No, | ISSUE
Email :- info@rienmac. biz Website:— www.rienmac.biz This drawing is not_to be copied or amended without written permission from Rienmac Consul E ae Rl ENECKER = RPEQ@ 2088 DO NOT SCALE OFF DRAWINGS, A3 SHEET 2 OF 3 CHECKED: PLR

 

 

 

 

 

 

 

 

Page 3

c3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a
a
° Lé
Ove = < “ i.
| 2/3 2/53
|B = = “4
col} 33 co
SHOT EDGE TIMBER | “ “ RS
DECKING ONLY. a = ° |
a T
|o fa a
| mw
Cl ied 5 |
OVER 7 2/iI f
|
le |
LLLLLL LL ZL LILI FLL LL ZL ZZ ZA
IS ok
BI CANTILEVERS. t" -
apnea
OVER | L 3 |
| a
la IS a
SHOT EDGE TIMBER | |B2 S 0
DECKING ONLY |
™__ R3
| 3 53 |
=! 1S
la af ob yo les
| 2/53 2/13
Cl st
Oa ai 122 R2 L
L6 4
2
5
b
C3

FIRST FLOOR FRAMING PLAN

 

 

PETER RIENECKER - RPEQ 2088

This drawing is not to be copied or amended without written

permission fram Rienmoc Consulting Engineers

 

SEE MEMBER SCHEDULE
ON DRAWING 55.

 

 

 

RIENMAC eryit

A.BN. 52 010 666 430 A.C.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR, P:- (07) 5478 250

  

SAINT CIRINO, F:- (07) 5444 (158
137 BRISBANE ROAD, Email:- info@rienmac. biz
(PO BOX 149) info@rienmac,ne'

MOOLOOLABA QLD 4557 Web:— www ,rienmac, bi:

 

CLIENT:
GEOFF CONNAN
PROJECT:

PROPOSED DUPLEX

38 ELANDA STREET
SUNSHINE BEACH @LD 4567

REAL PROPERTY DESCRIPTION ¢ COUNCIL:
LOT 158

COUNTY OF MARCH, PARISH OF WEYBA
NOOSA SHIRE COUNCIL
DRAWING TITLE:

FIRST FLOOR FRAMING PLAN

 

Designed: PLR Drawn: LR

 

SCALES: 1:100

 

Engineer: PLR |DATE: 15 NOV 16

 

16436 | 53) P2

JOB NUMBER DWG No, | ISSUE

 

 

 

 

DO NOT SCALE OFF DRAWINGS,

A3

 

SHEET 3 OF 13 |CHECKED: PLR

 

 

 

Page 4

 

 

RAFTER.

3/l00mm No 14 TYPE 17 BATTEN SCREWS

earn TO BLOCKING PIECE.

 

 

 
 

 

 

 

 

[<——FASICA.

 

 

 

 

\
RAFTER OR
TRUSS.

BLOCKING PIECES SAME SIZE AS
RAFTER UNDER EACH BATTEN.
| FRAMING ANCHOR EACH END.

WALL FRAMING.

O/HANG DETAIL MAX 900

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7 7 LL 13 _ iz “Tae J
ay i 4 =|
| uw 2 ] L2
NX ax L5 L LS
@ Z uh 4 (|
| a Se a] N ln N 2
> a a aa on S
25) ‘fe a Ss ~
| RI loz RI =—_— =— == o 2/Ri_ |S
fy
2/RI @
‘ RI
L RI : n
Ch 7 _
4k!
s
Si Lp ij} Priel
[
| iN i eee eee ee
a RI
[cl RI ad
| r Rl
I RI RI 4 Loo
“Sg _ =—s = RI 1S
a<|} |9 a 4
| a Su aa N ky
& > a“
MS LS = |__| L8
| Z L2
oO | |
aw N [Lt] £3 ut TRI
| LCL — {rd

|

 

BATTENS CANTILEVER FOR ROOF OVERHANG
TYPICALLY. NOTE INTERNAL WALL ARE
LOADBEARING SUPPORTING RAFTER.

ROOF FRAMING PLAN

 

 

PETER RIENECKER - RPEQ 2088

 

 

BLOCK WALL TO EXTEND TO U/S OF

ROOF SHEETING FOR FIRE SEPARATION,

RIENMAC eryit

A.BN. 52 010 666 430 A.C.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:

SUITE 5, FIRST FLOOR, P:- (07) 5478 250
SAINT CIRINO, F:- (07) 5444 (159
137 BRISBANE ROAD, Email:- [email protected]|
(PO BOX 149) info@rienmac,ne'
MOOLOOLABA @LD__4557 Web:— www ,rienmac, bi:
CLIENT:

GEOFF CONNAN
PROJECT:

PROPOSED DUPLEX

 

38 ELANDA STREET
SUNSHINE BEACH @LD 4567

REAL PROPERTY DESCRIPTION ¢ COUNCIL:
LOT 158

COUNTY OF MARCH, PARISH OF WEYBA
NOOSA SHIRE COUNCIL
DRAWING TITLE:

ROOF FRAMING PLAN

 

 

 

 

 

 

DETAILS

Designed: PLR Drawn: LR

SCALES: 1:100, 1:20

Engineer: PLR |DATE: 15 NOV 16
perniasion fram Renae Coraultig Engreers “| JOB NUMBER DWG No. | ISSUE
DO NOT SCALE OFF DRAWINGS. | AS |SHEET 4 OF 13 |CHECKED: PLR

 

 

 

 

Page 5

MEMBER SCHEDULE AND NOTES
DESIGN WIND SPEED = WIND CLASSIFICATION N3 - AS4055,

BUILDER TO VERIFY EXISTING CONDITIONS ARE AS PER THESE DRAWINGS BEFORE
ORDERING MATERIALS OR COMMENCING WORK. REFER ANY DISCREPANCIES TO ENGINEER
FOR DECISION,

ALL TIMBER EXPOSED TO THE WEATHER TO BE DURABILITY CLASS 2 OR BETTER.

LAMBEAMS ¢ LVL's EXPOSED TO THE WEATHER ARE TO BE PROTECTED IN ACCORDANCE
WITH MANUFACTURERS SPECIFICATIONS,

TIEDOWN ENDS OF ALL LINTELS AND ROOF BEAMS WITH |/MI2 ANCHOR ROD, UNO,
ALL MEMBERS NOTED AS H3 TREATED ARE TO BE H3 TRU-CORE TREATED.

WALL FRAMING

STUDS - 90x35 MGPI2 STUDS @450 CRS MAX NOT NOTCHED.

TOP PLATE - 2/90x35 MGPI2, TIEDOWN WITH MI2 ANCHOR RODS AT ENDS AND @1800
CRS MAX FOR ROOF SPANS UP TO 4.3m AND @1200 CRS MAX FOR ROOF SPANS UP TO
7.2m,

BOTTOM PLATE - 90x35 MGPI2. STUDS TO BE IN LINE WITH JOISTS OR PROVIDE

SOLID NOGGING IN BETWEEN FOR SUPPORT.

STUDS BESIDE OPENINGS 0 - 2600 2 STUDS
2600 - 4300 3 STUDS
4300 - 4500 4 STUDS
>4500 - 75x75x4,0 SHS,

BATTENS (METAL ROOF) - 38x75 Fil @900 CRS MAX.
TO EACH RAFTER / TRUSS,

1/75mm No |4 TYPE !7 SCREW

BI - 200UB25,

B2 - 250UB37 CANTILEVER TO SUPPORT Bl.

B3 - 185x85 2IC LAMBEAM IN PLANE OF JOISTS.

B4 - 195x85 17C LAMBEAM CONT SPAN IN PLANE OF JOISTS.

B5 - 230x85 17C LAMBEAM IN PLANE OF JOISTS H3 TREATED.

Bé - 170x63 HYSPAN IN PLANE OF JOISTS. JOIST HANGERS TO JI,

B7 - 195x85 17C LAMBEAM IN PLANE OF JOISTS.

B& - 230x85 17C LAMBEAM IN PLANE OF JOISTS.

Bq - 230x65 I7C LAMBEAM FASCIA BEARER. JOIST HANGERS TO EACH JOIST H3
TREATED.

BIO - 260x85 17C LAMBEAM.
BIl - 240x63 HYSPAN IN PLANE OF JOISTS.

Cl - 75x75x4.0 SHS COLUMN. C2 - 89x89x3.5 SHS COLUMN.
C3 - 89x89x3.5 SHS COLUMN FIRE RATED IF REQUIRED,
C4 - 89x89x3,.5 SHS COLUMN,

DOUBLE JOISTS UNDER ALL LOADBEARING WALLS, UNO,

DJ - DOUBLE JOISTS.

Jl - 140x45 MGPI2 JOISTS @450mm CRS MAX H3 TREATED,

J2 - 170x45 HYSPAN JOISTS @450mm CRS MAX, CONT SPAN WHERE POSSIBLE.
J3 - 240x45 HYSPAN JOISTS @450mm CRS MAX.

JRI - 200x45 HYSPAN JACK RAFTERS @900mm CRS MAX, | FRAMING ANCHOR EACH
SUPPORT.

ALL LINTELS ARE HYSPAN, UNO,
LI - DOUBLE TOP PLATE. L2 - 90x63. L3 - 130x63
L5 - 170x63 L@ - 200x63  L7 - 240x63

L4 - [50x63
L& - 300x63

PPI - 200x45 HYSPAN IN PLANE OF RAFTER, MI2 CHEMICAL ANCHORS TO BLOCK WALL
AT ENDS AND @900mm CRS MAX.

PP2 - 170x45 FI7KD POLE PLATE MI2 CHEMICAL ANCHORS TO BLOCK WALL AT ENDS
AND @600mm CRS MAX. JOIST HANGERS TO 2.

RI - 200x45 HYSPAN RAFTERS @900mm CRS MAX CONT SPAN WHERE POSSIBLE, |
FRAMING ANCHOR EACH SUPPORT.

R2, R3 - 90x45 HYSPAN RAFTERS @900mm CRS MAX. | FRAMING ANCHOR EACH
SUPPORT.

RBI - [95x85 17C LAMBEAM IN PLANE OF RAFTERS. JOIST HANGERS TO Rl.
RB2 - 165x65 17¢ LAMBEAM H3 TREATED.

RB3 - 200x63 HYSPAN IN PLANE OF RAFTERS.

RB4 - 15x65 17C LAMBEAM H3 TREATED,

C2

—————

 

  

!Omm END PLATE TO C2.
2/MI2 TO WALL FRAMING
DOUBLE TOP PLATE.

a

lOmm BASE PLATE TO C2.
2/Ml2 HD BOLTS TO SLAB,
BEARER OR DOUBLE JOIST.

DETAILS UNO

lOmm CLEAT PLATE TO C2.
2/M|2 TO LINTEL.

lOmm ANGLE. 2/Mlé
CHEMICAL ANCHORS TO
BLOCK WALL. 2/M20 TO B8.

 

BS ~<

 

 

 

BS TO BLOCKWALL

 

 

lOmm ANGLE 2/MIé BOLTS
EACH CONNECTION.

2/53

 

 

B

 

Bil

 

 

    

[25x50 Fl4 POLE PLATE, 7 HB

MI2 HD BOLTS AT
AND @1200mm CRS.

F

RB4 DETAILS SIMILAR,

!Omm END PLATE TO Cl.

2/M|2 TO RB2.

lOmm 'T' BASE PLATE TO

TRIM FLANGES OF B2.

lOmm CLEAT PLATE TO BI, FULL DEPTH

lOmm ANGLE 2/Mlé TO BS.
2/Mlé TO B4.

| |

 

   

a

T|\_l0mm END
PLATE TOP C4,
2/MI2 TO B4.

Bs TO BA

 

WELD TO FLANGES AND WEB OF BI.

2/Mlé TO B2.

Cl BETWEEN JOISTS.
2/Ml2 BOLTS.

FIX 2/JI AT Cl TO BI

 

Ap
Bt

©

 

t

2/ JI

WITH MI2 HD BOLTS.

Lat

 

 

 

NOTE: SECTION IS NOT A

TRUE SECTION Cl,
C3 ARE AT DIFFER’
LOCATIONS.

 

 

 

 

 

 

 

 

 

 

 

 

¢

 

TO 2/33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(B3 DETAILS SIMILAR)

RIENMAC eryit

A.BN. 52 010 666 430 A.C.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS

   

 

 

 

 

 

 

 

 

lo > >< < SUNSHINE COAST OFFICE:
ENDS ai lle B2 7 4 B2 ‘4 B2 SUITE 5, FIRST FLOOR, P:- (07) 5478 250
‘4 SAINT CIRINO, (07) 5444 |I58
iw [37 BRISBANE ROAD, Email:- info@rienmac. biz
lomm END PLATE TO C3. \40x45 MGPI2 PLATE. MI2 HD BOLTS (PO Box 144) [email protected]
C é c3 ola To Bi. C2 AT eND AND €1200mm CRS. 100.00. ABA QLD 4557 Web:-_www,rienmac,bi
Lt lOmm END PLATE TO , GEOFF CONNAN
C2, 4/MI2 TO B2. PROJECT:
lomm BASE PLATE TO C2.
| C2 2/MI2 HD BOLTS CONCEAL IN PROPOSED DUPLEX
SLAB ON GROUND lOmm BASE PLATE. Joma FRAMING,
AS DETAILED. ~. (amie HD BOLTS. it 38 ELANDA STREET
J iE SUNSHINE BEACH QLD 4567
Re __ for ten DESCRIPTION # COUNCIL:
~ COUNTY OF MARCH, PARISH OF WEYBA
NOOSA SHIRE COUNCIL
DRAWING TITLE:
= MEMBERS SCHEDULE
r DETAILS
3 FBI € FB2
8 Designed: PLR Drawn: LR
s 4/NI2 COGGED BARS, R6
| —tles @400mm CRS 65 SCALES: 1:20
COVER. SECT | ON Engineer: PLR |DATE: 15 NOV |6
oo “TYPICAL PFI
— ee 16436 55 | P2
PFI permission tam Riennse Contig Engreers “| JOB NUMBER DWG No. | ISSUE
PETER RIENECKER - RPEQ 2088 | DO NOT SCALE OFF DRAWINGS, | A3 |SHEET 5 OF 13 |CHECKED: PLR

 

 

 

 

 

 

Page 6

 

 

      

 

 

.8P .8P

 

LILI
KONI LIL

KONO UO
LILI

0.aP.

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

Zz
va
~
om} Zz
— V4
BRACING NOTES vf
- INDICATES BRACING WALL AND ANCHOR RODS. 8 "
1.2P INDICATES PLYWOOD NAILED TO STUDS AS PER METHOD A OF ASI684 G ROU N D F LOOR B RAC | NG P LAN FY a
TABLE 8,.18(h) AND HOLD DOWN WITH ANCHOR RODS AT EACH END TO ACHIEVE Q
6.4kN/m BRACING STRENGTH. w >
BRACING DETAILS AS PER ASIG84 - PART 2 FOR N3 WIND CLASSIFICATION, 'e' ANCHOR ROD LOCATIONS 1 x v
AS PER ASIG84 FOR BRACING FORCE REQ'D = 67kN Pla
ALL BRACING WALLS ARE TO BE CONNECTED TO THE CEILING FRAMING AS PER WALLS ONLY TT
ASI684 TABLE 8.22 TO TRANSFER THE DESIGNATED FORCES. . PROVIDED = >77kN
A.B.N, 52 010 666 430 | CIENT: Designed: PLR|SCALES: 1:100
RIENMAC pry trp NEN 010 ee 420. | GEOFF CONAN |
PROJECT: Engineer: PLR|DRAWN: LR |DATE: 15 NOV |é
CONSULTING CIVIL € STRUCTURAL ENGINEERS ERCP OSED QUE EX
SUNSHINE COAST OFFICE: LOT 156
SUITE 5, FIRST FLOOR, SAINT CIRINO, 137 BRISBANE ROAD, | SUNSHINE BEACH QLD 4567 COUNTY OF MARCH PARISH OF WEYBA 16436 S6 Pl
(PO BOX 149) MOOLOOLABA @LD 4557 DRAWING TITLE: NOOSA SHIRE COUNCIL
Phone:- (07) 5478 2500 Fax:- (07) 5444 1158 GROUND FLOOR BRACING PLAN REAL PROPERTY DESCRIPTION ¢ COUNCIL: JOB NUMBER DWG_No. | ISSUE
Emai ~ info@rienmac. biz Website:— www.rienmac.biz This drawing is not_to be copied or amended without written permission from Rienmac Consul E ae RI ENECKER = RPEQ 2088 DO_NOT SCALE OFF DRANINGS, A3 SHEET 6 OF 3 CHECKED: PLR

 

 

 

 

 

 

 

Page 7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[- 0.9 a
q oo
(P aI fT [- 0.9P “|
| OER 3 | &
= te c—F) L-—4 IS
| 0.92
| =] H fo
| q
&
5 iS
ao a io
Low ofils iS
qu :
oO
— Ou
e-
| a ° B20
t tt
tf
| fo.
eS
a Ss a
5
anes - RIENMAC
— ey a PTY LTD
[ ° oS S A.B.N. 52 010 666 430 A.C.N. 010 666 430
io. CONSULTING CIVIL ¢
| S z STRUCTURAL ENGINEERS
— = H al SUNSHINE COAST OFFICE:
OP SUITE 5, FIRST FLOOR, P:- (07) 5478 250
| SAINT CIRINO, F:- (07) 5444 lI5d
—O —/ |__| a 37 BRISBANE ROAD Email: [email protected]
= at rr io (PO BOX 149) ‘ [email protected]
| . 2 | > MOOLOOLABA @LD__4557 Web:— www ,rienmac, bi:
0.4P CLIENT:
. 5 = u L a GEOFF CONNAN
| 0.4P _|
PROJECT:
Z PROPOSED DUPLEX
$1
ss 38 ELANDA STREET
FIRST FLOOR BRACING PLAN ee umnmraamravene
&
L G L ra a REAL PROPERTY DESCRIPTION # COUNCIL:
aw | LOT {58
wu |S COUNTY OF MARCH, PARISH OF WEYBA
Q18 NOOSA SHIRE COUNCIL
vw DRAWING TITLE:
FORCE REQ@'D = 28kN la FIRST FLOOR BRACING PLAN
SS
PROVIDED = 44kN
BRACING NOTES Designed: PLR = Drawn: LR
- INDICATES BRACING WALL AND ANCHOR RODS. Me! ANCHOR ROD LOCATIONS SCALES: 1:100
—. . :
|.2P INDICATES PLYWOOD NAILED TO STUDS AS PER METHOD A OF ASI684 AS PER ASIG84 FOR BRACING ineer: :
TABLE 8.16(h) AND HOLD DOWN WITH ANCHOR RODS AT EACH END TO ACHIEVE WALLS ONLY Engineer: PLR |DATE: 15 NOV l6
6.4kN/m BRACING STRENGTH, :
BRACING DETAILS AS PER ASI684 - PART 2 FOR N3 WIND CLASSIFICATION. 16436 S7 P|
ALL BRACING WALLS ARE TO BE CONNECTED TO THE CEILING FRAMING AS PER is drawing i , without uri
ASI684 TABLE 8.22 TO TRANSFER THE DESIGNATED FORCES. senrition Grn Rianne: Coeslting Eanes twits | JOB NUMBER DWG No. | ISSUE
PETER RIENECKER - RPEQ 2088 | | Do Not SCALE orF DRAWINGS. | A3 |SHEET 7 OF 13 |CHECKED: PLR

 

 

 

 

 

 

 

Page 8

| LAYER F82 FABRIC.
30 TOP COVER.

     

FORM KEY IN EDGE OF Ist POURED SLAB COAST
FACE OF SLAB WITH BOND PREVENTATIVE.

  

 

 

 

 

 

 

 

 

 

   

 

 

 

 

F.S.L
BOLSTER CUT SLAB (3Wx30D), FILL (eg. HYDROSEAL, FORMOIL). 8
| LAYER F72 FABRIC. JOINT TO 30mm BELOW SURFACE WITH on
30 TOP COVER, FOSROC EXPANDITE THIOFLEX 600G. oo
4 5.0 J ; 50 SAND BED AND
= —— —T ts] WATERPROOF MEMBRANE.
9 & =f
g | LI | “Ip 50 BOTTOM COVER
300 SUBGRADE TO BE COMPACTED TO 98% CUT EVERY 2nd WIRE DIRECTLY UNDER 3 BAR FIITM. RIO TIES @600 CRS.
[__300_,| STANDARD COMPACTION (TEST EI.| ASI289). JOINT ¢ DEPRESS FABRIC LOCALLY. 50 BOTTOM COVER.
EDGE THICKENING (ET) TOOLED JOINT (TJ) (KJ) E.B. DETAILS
TYPICAL TO ALL EDGES OF DRIVEWAY SLAB. ALTERNATIVELY: SAW CUT SLAB 3Wx30D WITHIN
DISCONTINUE FABRIC 40mm FROM END. 24 HOURS OF CASTING SEAL AS ABOVE.

3/NI2 Z BARS EACH

DRIVEWAY SLAB ON GROUND DETAILS “ae

 

 

300
MAX
Zz

 

 

 

 

 

 

 

 

DRIVEWAY NOTES: 500

|. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL.
2, CROSSINGS ARE NOT DESIGNED FOR COMMERCIAL VEHICLES, FOOT | G ST E P
3.

CONCRETE DRIVEWAY TO BE [25mm THICK EXCLUDING ANY FINISH

TREATMENTS. eg. STAMPED CONCRETE FINISH.
4, CONCRETE SURFACE TOLERANCE TO BE 0-5mm, OVER 3 METRE D ETAI LS
SECTIONS. a
5. CONCRETE N25 IN ACCORDANCE WITH ASI374 AND AS3600.

6, REINFORCEMENT FABRIC TO ASI304, 50 TOP AND EDGE COVER, LAP
FABRIC 250. 190 BLOCKWALL

7, APPROVED MATERIALS FOR CONSTRUCTION:- CONCRETE or ASPHALT.
8. EXPANSION JOINTS TO BE l0mm WIDE, FULL DEPTH CLOSED CELL CROSS

 

 

 

 

 

       

RIENMAC eryit

      

LINKED POLYETHYLENE FOAM (85-|50kg/m3) OR COMPRESSED NI2 VER BARS @400 CRS, LAP A.B.N. 52 010 666 430 A.C.N. 010 666 430
GRANULATED CORKBOARD, INSTALLATION TO MANUFACTURERS 500 WITH NI2 FROM FOOTING. CONSULTING CIVIL ¢
INSTRUCTIONS. NI2 HOR BARS @400 CRS. LAP STRUCTURAL ENGINEERS
BARRIER/SEMI-MOUNTABLE 9. ALL DIMENSIONS IN MILLIMETERS. 450 WHERE REQ'D AND AT
KERB AND CHANNEL. 7) 10. ONE ACCESS POINT TO BE CONSTRUCTED TO EACH LOT AS PER CORNERS. SUNSEINE COAST Oe: P:- (07) 5478 250
STANDARD DRANING. SAINT CIRINO, ‘ - (07) 5444 (15d

   

FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO INSIDE EDGE OF 137 BRISBANE ROAD, Email:- info@rienmac. biz!
CURVE. (PO BOX 144) info@rienmac,ne
12. ALL SERVICES NEED TO BE LOCATED PRIOR TO EXCAVATION. BLOCK WALL TO BE ON EDGE OF MOOLOOLABA QLD 4557 Web:- www, rienmac.bi

 

0
=

CLIENT:

FOOTING WHEN ON BOUNDARY. GEOFF CONNAN

FOOTPATH
PROPERTY BOUNDARY

000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

— 2 PROJECT:
yz
DRIVEWAY DETAILS AND 3|= PROPOSED DUPLEX
z NOTES TAKEN FROM COUNCIL =a 3 BAR F8TM TOP &
| sve zr RESIDENTIAL DRIVEWAY si F72 MIN FABRIC. BOTTOM. Rio Las 38 ELANDA STREET
‘ 3 DRAWING R-0050. :
SoS
CONSTRUCTION | = Q S re ae SUNSHINE BEACH @LD 4567
‘ ~ for ten DESCRIPTION # COUNCIL:
B S — COUNTY OF MARCH, PARISH OF WEYBA
~ S 3 NOOSA SHIRE COUNCIL
z | berals”
=
MOUNTABLE KERB L a SAND BED.
AND CHANNEL. 8 | BARRIER, SAW CUT AND BREAKOUT o—s—8
2 SEMI-MOUNTABLE BACK OF KERB AND —— ;
* MOUNTABLE KERB ¢ CHANNEL. 350 Designed: PLR ~~ Drawn: LR
ALTERNATIVE PROFILE. CHANNEL OR INVERT SCALES: 120

 

 

 

 

CROSSING, SF | DETAILS Engineer: PLR |DATE: 15 NOV IG
DRIVEWAY DRIVEWAY CROSSING OS 16436 S81 Pl

C ROSS | N G P L A N D E TA | L parmisoan tram Riownee Cortina tngraers | SOB NUMBER DIG No. | ISSUE

PETER RIENECKER - RPEQ 2088 | DO NOT SCALE OFF DRAWINGS, | A3 |SHEET 8 OF [3 |CHECKED: PLR

 

 

 

 

 

 

 

 

 

 

 

Page 9

RIO TIES @600 CTS. BENT INTO
SLAB. LAP 400 WITH FABRIC

30 TOP COVER WITH

F82 FABRIC TOP.
30 COVER.

 

 

 

100

 

 

SR eee Sil

 

 

 

 

 

 

WATERPROOF

|<—— MEMBRANE - TYPICAL.
4 BAR FIITM BOTTOM.

400 a. BOTTOM COVER,

225 MIN - 450 MAX
TO SUIT LOCAL
AUTHORITY. MAINTAIN
FABRIC.
Kk, Ml
F.S.L ws
WN ye
- SK
8 YA v
a

WITH FABRIC, F82 FABRIC
TOP 30 COVER.
C 5.0.G.
1 4
F.S.L.
x KR
PERIMETER IN 4

FOOTING.
\47

 

50 MIN

EDGE BEAM FBI
STUD WALL

 

NOTES:-

REINFORCEMENT LAPS, U.N.O:-

F82 FABRIC - 2 CROSS WIRES (250mm)
FIITM - 2 CROSS WIRES (350mm)

CONCRETE WORK SHALL BE IN ACCORDANCE
WITH AS 3600.
= 25 MPa.

SLAB FABRIC SHALL BE SUPPORTED ON BAR
CHAIRS @800 CRS.

AT THE TIME OF INSPECTION, REINFORCEMENT
SHALL BE PLACED WITH PROVISION FOR
ADEQUATE COVER.

 

 

 

AT BEAM LOCATIONS 2/RIO
TIES @600 CTS. BENT INTO
SLAB. LAP 400 WITH FABRIC
MAINTAIN 30 TOP COVER

CONSTRUCTION BREAK.

 

 

 

 

 

 

 

ARTE ‘|
SA

3 BARS FIITM BTM TO

END WITH CROSS WIRE.

 

KG
BEAM FB2.

FOOTING BEAM FB2 TO
PERIMETER FOOTING

50 SAND BED.

 

WIT NI2 VER BARS @400 CRS CENTRALLY
IN WALL, LAP 500 WITH STARTERS
FROM FOOTING AND AT FIRST FLOOR
2 LEVEL.
NI2 HORIZONTAL BARS @400 CRS. LAP
500 WHERE REQUIRED ¢ AT CORNERS.

 

 

 

 

CRG _

 

MY A

FB2 AS —>|
DETAILED. |

FB2 WITH BLOCK WALL

RIO TIES @600 CRS.
ALTERNATE DIRECTION.

 

 

 

 

CONSTRUCTION BREAK.

~ “AP F82 FABRIC TOP

) Cc” COVER.

 

 

  
  

 

 

 

 

 

“SR A) - CREE
<| 50 SAND BED.
° yo | =
WATERPROOF ——

 

“—— MEMBRANE - TYPICAL.

 

50 MIN 50 MIN

BEAM FB2

 

IF FB2 IS NOT POURED INTEGRALLY
WITH EDGE BEAM, PROVIDE 2/NI2
BARS LAPPED 400 WITH BOTTOM
TRENCH MESH.

EDGE OF SLAB

      

EDGE OF FOOTING

EXTRA 2/NI2 BARS (OR 3 BAR F8TM)
DIAGONALLY ACROSS ALL CORNERS OF

R AN IDS.
F82 MESH. ECESSES AND VOIDS

30 TOP COVER. 400

ra
sp Ey Tt tgs
FA ee =
STEP IN SLAB DETAIL

LAP TRENCH MESH
FULL WIDTH

 

 

 

 

| col |

 

     

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXTRA NI2
TOP AND BOTTOM

 

INTERSECTION CORNER
EDGE BEAM

       

RIENMAC eryit

A.BN. 52 010 666 430 A.C.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR,
SAINT CIRINO,

[37 BRISBANE ROAD, Email:
(PO BOx |44)
MOOLOOLABA QLD 4557

3 BAR FIITM
50 EDGE COVER
2000 LONG

   

EDGE BEAM

P:- (07) 5478 2501
- (07) 5444 |I58
info@rienmac., biz|

[email protected]!
Web:- www.rienmac bi:

 

CLIENT:

GEOFF CONNAN
PROJECT:

PROPOSED DUPLEX

38 ELANDA STREET
SUNSHINE BEACH @LD 4567

 

 

VRP

y
SJ
SY

    

REAL PROPERTY DESCRIPTION ¢ COUNCIL:
LOT 158

COUNTY OF MARCH, PARISH OF WEYBA
NOOSA SHIRE COUNCIL
DRAWING TITLE:

DETAILS

PROVIDE ALSO AT
CORNERS OF ALL
RECESSES AND
VOIDS

 

 

 

 

 

 

 

 

 

 

 

 

SLAB RE-ENTRANT == =
SCALES: 1:20
CORN ER DETAI L Engineer: PLR |DATE: 15 NOV I6
TYPICAL FOR ALL CORNERS OF ALL RECESSES AND VOIDS 16436 Sg P|
Fea ee Bienes CeetieG Paros tot written | JOB NUMBER DWG No, | ISSUE
PETER RIENECKER - RPEQ 2088 | DO NOT SCALE OFF DRAWINGS, | A3 |SHEET 4% OF 13 |CHECKED: PLR

 

 

 

 

Page 10

Od

150.

 

 

 

 

 

 

 

 

 

 

 

 

 

300 DEERP-——_1

 

 

 

RUBBLE PIT.

500 SQ

Nees DRAIN LINE

EACH WAY

SL yorosranic VALVE

 

 

MAI!

 

N DR

AIN DETAIL

 

 

         

WATER LEVEL

 

SI2 BARS @300
CRS EACH WAY.

 

STEP

 

DETAIL

 

(INDICATIVE ONLY)

PROVIDE 2/512 HOR 1200 LONG TOP ¢ BOTTOM
AT SKIMMER BOX ¢ SIMILAR OPENINGS.

 

——

 

 

 

 

 

 

 

SKIMMER BOX

 

Lo
HYDROSTATIC VALVE TO BE __\

INSTALLED AT LOWEST POINT.

2/S|2 BARS EACH SIDE

SKIMMER

FILTER DISCHARGE TO COUNCIL 1.
REQUIREMENTS.

 

PUMP

 

 

 

 

MAIN DRAIN
TO POOL

INLETS

DIAGRAMMATIC WATER

POOL CONSTRUCTION SPECIFICATION

WORKMANSHIP € MATERIALS TO BE IN ACCORDANCE WITH AS2783 CONCRETE SWIMMING
POOL CODE AND LOCAL AUTHORITY'S REQUIREMENTS.

 

2. POOL FILLING # SOIL BACKFILLING NOT TO BE CARRIED OUT UNTIL WALLS &¢ FLOOR HAVE
REACHED DESIGN STRENGTH.

3. 50mm LAYER OF 22mm GRAVEL TO BE PLACED UNDER POOL FLOOR.
4, ALL CONCRETE ON PLAN TO BE 300mm RADIUS UNLESS NOTED OTHERNISE.

5. DEEP END TO HAVE AT LEAST 0.3m OF FIRM, NATURAL SOIL OR EQUIVALENT RETAINING
WALL, ETC AS SUPPORT.

Ss

SUPPORTING SOIL TO BE SOUND NATURAL SOIL OR WELL COMPACTED FILLING WITH
BEARING CAPACITY AT ANY DEPTH NOT LESS THAN |00kPa.

 

RETICULATION :

THIS DESIGN APPLIES FOR FLAT SITES AND UNIFORM GROUND CONDITIONS ONLY. ON
SLOPING SITES PROVIDE RETAINING WALLS OR CUT/FILL WITH CONTROLLED COMPACTION
OF FILLING TO MATCH NATURAL SOIL CONDITIONS. ON CUT @ FILL SITES A BEAM NOT

 

LESS THAN TWICE THE DEPTH OF THE FILL AT THE POOL |S REQUIRED BEYOND THE POOL
WALL.

8. DESIGN TO BE MODIFIED IF EXCESS GROUND WATER IS ENCOUNTERED DURING
EXCAVATION.

9. ALL DIMENSIONS ON SITE PLAN SHOWING THE POSITION OF THE POOL ARE TO THE WATER
FACE.

POOL OWNER TO BE INFORMED THAT AN ELEMENT OF RISK TO THE POOL STRUCTURE |S
INVOLVED IF THE POOL IS EMPTIED.

ALL DETAILS TO BE IN

ACCORDANCE WITH
BESSER SPECIFICATIONS.

BLOCK POOL SPECIFICATIONS

 

ALL WORKMANSHIP AND MATERIALS SHALL BE IN
ACCORDANCE WITH THE 5.A.A, CODES:

* AS53600 CONCRETE STRUCTURES.

* AS53700 MASONRY CODE BLOCKWORK.

BLOCKS TO BE 20.18, 20.48, 20.21 AS SUPPLIED
BY BESSER (QLD) LIMITED.

ULTIMATE COMPRESSIVE STRENGTH OF CONCRETE
(Fic) TO BE 32MPa, FLOOR CONCRETE TO BE
VIBRATED.

FLOOR CONCRETE TO BE [50 THICK.

I50 THICK POOL BASE.

800 MAX

512 BARS @200 CRS MAX

EACH WAY CENTRAL IN

‘

 

w
S
S

 

N
S
S

 

Vt

7 A

20-18

 

 

 

RIENMAC eryit

A.BN. 52 010 666 430 A.C.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR,

 

GROUND

20-48-—~s LEVEL

 

 

RE.
Mx

| ~NI2 VER BARS CENTRAL P:- (07) 5478 250

   

 

 

 

IN’7] fon poo. DEPTS UP 137 BRISBANE. ROAD, Email ubrineec i

Ler cee FOR POOL DEPTHS (OODOLASS cup 4667 we Suea'tnee a
UP TO 100mm. GEOFF CONNAN

piey Nip HOR BARS @200 CRS PROJECT:

TO BLOCKWALL. LAP PROPOSED DUPLEX

450 WHERE REQ'D AND

 

 

              

 

 

 

 

 

 

 

 

 

 

HYDROSTATIC VALVE

 

 

 

 

 

 

2 EXTRA 512 TH77] AT CORNERS
POOL SHELL. LAP 600 ‘ 38 ELANDA STREET
WHERE REQ'D. LONGITUDINALLY. SUNSHINE BEACH QLD 4567
| 20-18 REAL PROPERTY DESCRIPTION # COUNCIL:
LOT 158
COUNTY OF MARCH, PARISH OF WEYBA
wo NOOSA SHIRE COUNCIL
TF .
KKK 225 DETAILS.
PROVIDE Nié TIE BARS TO
POOL BASE REINF'T AT
EACH VER BAR. LAP 600 Designed: PLR Drawn: LR
| WITH POOL REINF'T AND 500
| WITH WALL REINF'T, SCALES: 1:20
: TYPICAL IN-GROUND BLOCK = Eero
DOL DEeTAU 164326 | SIO) Pl
UVUE VETAIL perniasion fram Renae Coraultig Engreers “| JOB NUMBER DWG No. | ISSUE
PETER RIENECKER - RPEQ 2088 | DO NOT SCALE OFF DRAWINGS. | A3 |SHEET 10 OF 13 |CHECKED: PLR

 

 

 

 

 

 

Page 11

GENERAL NOTES

¢ THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL ARCHITECTURAL AND OTHER
CONSULTANTS DRAWINGS AND SPECIFICATIONS AND WITH SUCH OTHER WRITTEN INSTRUCTIONS AS
MAY BE ISSUED DURING THE COURSE OF THE CONTRACT. ALL DISCREPANCIES SHALL BE
REFERRED TO THE SUPERINTENDENT FOR DECISION BEFORE PROCEEDING WITH THE WORK.

¢ ALL DIMENSIONS RELEVANT TO SETTING OUT AND OFF-SITE WORK SHALL BE VERIFIED BY THE
CONTRACTOR BEFORE CONSTRUCTION AND FABRICATION IS COMMENCED. THE ENGINEER'S
DRAWINGS SHALL NOT BE SCALED.

e DURING CONSTRUCTION THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE
STRUCTURE IN A STABLE CONDITION AND ENSURE NO PART IS OVER-STRESSED,

e WHERE EXCAVATION WORK IS TO BE CARRIED OUT ADJACENT TO EXISTING FOOTINGS, THE EXACT
LEVEL OF THE UNDERSIDE OF THE FOOTINGS SHALL BE OBTAINED BY TEST PITS PRIOR TO
EXCAVATION, UNDERPINNING AND SHORING OF THE STRUCTURE SHALL BE CARRIED OUT AS
REQUIRED AND THE EXISTING STRUCTURE SHALL BE MAINTAINED IN A STABLE AND UNDAMAGED
CONDITION,

« WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH THE RELEVANT CURRENT SAA
CODES (INCLUDING ALL AMENDMENTS) AND THE STATUTORY AUTHORITIES REQUIREMENTS,
EXCEPT WHERE VARIED BY THE CONTRACT DOCUMENTS.

e ALL DIMENSIONS ARE IN MILLIMETRES, UNLESS NOTES OTHERWISE. ALL LEVELS ARE EXPRESSED
IN METRES,

FOOTING NOTES
e ALL FOOTING EXCAVATIONS SHALL BE CLEANED OF LOOSE MATERIALS AND WATER,

e WHERE VERIFIED FOUNDATION MATERIAL IS BELOW THE UNDERSIDE OF FOOTINGS AS DETAILED,
BACKFILL ADDITIONAL EXCAVATION WITH WEAK MIX CONCRETE.

¢ SIDES OF FOOTINGS SHALL BE FORMED AS NECESSARY WHEN EXCAVATED FACE |S NOT STABLE.

e ALL WALLS AND COLUMNS SHALL BE CONCENTRIC WITH SUPPORTING FOOTINGS, UNLESS
OTHERWISE NOTED ON THE DRAWINGS.

e UNLESS APPROVED BY THE SUPERINTENDENT, EXCAVATIONS SHALL NOT EXTEND BELOW A LINE
DIPPING AT 30° AND AWAY FROM THE NEAREST UNDERSIDE CORNER OF ANY FOOTINGS.

CONCRETE NOTES

e« ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS3600,

« ALL SLABS ON GROUND TO BE CAST ON A WATERPROOF MEMBRANE ON A 50mm SAND BED.
MEMBRANE IS TO EXTEND UNDER INTEGRAL GROUND BEAMS AND IS TO BE EXTENDED A MINIMUM
OF 200mm DOWN THE FACE OF DEEP BEAMS. MEMBRANE |S TO BE POLYETHYLENE FILM 0.2mm
THICK AND IMPACT RESISTANT. LAP JOINTS 200mm AND SEAL THE LAPS WITH WATERPROOF
ADHESIVE TAPE. SEAL PENETRATIONS WITH WATERPROOF TAPE.

¢ PROVIDE A TERMITE BARRIER IN ACCORDANCE WITH AS3660.I,

e« ALL CONCRETE TO BE VIBRATED,

« CONCRETE QUALITY SHALL BE NORMAL CLASS, UNLESS NOTED OTHERWISE.
MAXIMUM AGGREGATE SIZE = 20mm.
SLUMP = 80mm +/- I5mm. Fic - 25MPa.

BLOCKWORK NOTES

¢ BLOCKWORK SHALL NOT BE FILLED TO A HEIGHT OF GREATER THAN 2400mm, DURING ANY ONE
POUR,

« CONCRETE BLOCKS TO HAVE A CHARACTERISTIC STRENGTH OF IS5MPa MINIMUM.
e BUILD ALL FIXINGS FOR ARCHITECTURAL DETAILS,

e« ALL BLOCKWORK MATERIALS AND WORKMANSHIP SHALL COMPLY WITH AS3700. BLOCKS FOR USE
IN REINFORCED CONCRETE FILLED WALLS SHALL BE 20.48 ¢ 15.48 SERIES.

* MORTAR SHALL BE MIXED BY MECHANICAL MIXERS IN ACCORDANCE WITH ASI23 IN THE FOLLOWING
PROPORTIONS BY VOLUME OF- PORTLAND CEMENT : HYDRATED LIME : CLEAN PIT SAND,
- BELOW DAMP COURSE LEVEL | 0.25 : 3
- ABOVE DAMP COURSE LEVEL | [: 6
ALL BLOCKS SHALL BE LAID ON A FULL BED OF MORTAR,

 

e ALL WALLS SHALL BE BONDED OR TIED AT THEIR INTERSECTIONS.

« REINFORCED CONCRETE MASONRY WALLS SHALL BE FILLED WITH GROUT OF F'c = 20MPa; SLUMP =
225mm; MAXIMUM AGGREGATE SIZE = 5mm; CLEAN OUT BLOCKS SHALL BE EMPLOYED IN THE
BOTTOM COURSE AND ALL MORTAR DROPPINGS RAKED OUT PRIOR TO FILLING.

* GROUT FILLING SHALL BE THOROUGHLY RODDED USING A PLAIN ROUND BAR,

TIMBER NOTES

e« ALL TIMBER ELEMENTS AND CONSTRUCTION DETAIL ARE TO COMPLY WITH THE DETAILS GIVEN IN
ASI684 NATIONAL TIMBER FRAMING CODE WIND CLASSIFICATION N3.

¢« ALL TRUSSES TO BE DESIGNED BY THE MANUFACTURER TO THE WIND LOAD SPECIFIED, THE
TRUSS MANUFACTURER IS TO SPECIFY THE TIEDOWN TO TOP PLATE APPROPRIATE TO THE
SPECIFIED DESIGN WIND VELOCITY,

« ALL TIE DOWN DETAILS TO BE SUBMITTED TO THE SUPERINTENDENT FOR VERIFICATION.

STRUCTURAL STEELWORK NOTES

« ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS4I00, AS/NZ94600,
AS/NZSI554 AND AS/NZSHB62.

« UNLESS NOTED OTHERWISE, ALL STEEL SHALL BE:
- GRADE 300 PLUS FOR HOT ROLLED SECTIONS,
GRADE 300 PLUS FOR WELDED SECTIONS (WB, WC).
- GRADE 300 PLUS FOR MERCHANT BAR (ROUND, SQUARE AND FLAT).
- GRADE 250 FOR PLATES.
- GRADE C350 FOR RHS, SHS AND CHS.

‘

 

* COMMERCIAL GRADE BOLTS SHALL CONFORM TO AS/NZSIII| AND AS4I00. HIGH STRENGTH
STRUCTURAL BOLTS SHALL CONFORM TO AS/NZS5I252 AND AS4I00. WELDS SHALL CONFORM TO
AS/NZ51554 AND WELDING ELECTRODES TO AS/NZSI553.

« ALL DETAILS, GAUGE LINES, ETC, WHERE NOT SPECIFICALLY SHOWN ARE TO BE IN ACCORDANCE
WITH AISC DESIGN CAPACITY TABLES FOR STRUCTURAL STEEL AND AISC STANDARDISED
STRUCTURAL CONNECTIONS,

¢ BEFORE FABRICATION IS COMMENCED THE CONTRACTOR SHALL SUBMIT COPIES OF THE SHOP
DRAWINGS TO RIENMAC FOR REVIEW. REVIEW DOES NOT INCLUDE CHECKING OF DIMENSIONS.

e UNLESS NOTED OTHERWISE, ALL WELDS SHALL BE 6mm CONTINUOUS FILLET FROM E48XX
ELECTRODES, ALL WELDS SHALL BE CATEGORY SP,

« ALL BOLTS SHALL BE GRADE 8.8/5 UNLESS NOTED OTHERNISE.
ALL BOLTS SHALL BE M20, UNLESS NOTED OTHERNISE.

« ALL CLEATS AND GUSSETS SHALL BE l0mm PLATE, UNLESS NOTED OTHERWISE.

« CONCRETE ENCASED STEELWORK SHALL HAVE A MINIMUM OF 50mm OF CONCRETE ENCASEMENT
REINFORCED WITH W5 WIRE WRAPPING AT 150 CRS OR FGW4I FABRIC, UNLESS NOTED OTHERNISE.

¢ STRUCTURAL STEELWORK SHALL HAVE THE FOLLOWING SURFACE TREATMENT IN ACCORDANCE
WITH AS/NZS2312, UNLESS NOTED OTHERNISE.

ELEMENT SURFACE CLEANING PRIME COAT TOP COATS
ALL STEELWORKSs~=~<CS~sSs*~*~S*«SS MICRONS =—SCREFER ARCHITECT
WITHIN AIRSEAL CLASS | ZINCPHOSPHATE

OF BUILDING

ALL STEELWORK HOT DIP REFER ARCHITECT
OUTSIDE AIRSEAL CLASS 2.5 GALVANISED

OF BUILDING

« MEMBERS TO BE ENCASED IN CONCRETE OR FIRE SPRAYED MUST NOT BE PAINTED.

« ALL HOT DIP GALVANISED MEMBERS SHALL BE PROVIDED WITH VENT AND DRAINAGE HOLES IN
ACCORDANCE WITH THE GALVANISER'S RECOMMENDATIONS.

e« WHERE MEMBERS SHOWN ON THE STRUCTURAL OR ARCHITECTURAL DRAWINGS ARE REQUIRED TO
BE CURVED, BENT OR ROLLED, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE METHODS
REQUIRED TO ACHIEVE THE REQUIRED SHAPES WITHOUT LOCALISED DISTORTION OF THE MEMBERS,

«TRIMMING MEMBERS FOR MECHANICAL/HYDRAULIC PENETRATIONS ARE NOT NECESSARILY SHOWN.

¢ TRIMMING MEMBERS FOR VALLEYS, FREE EDGES, RIDGES, ETC ARE NOT NECESSARILY SHOWN.
REFER TO PURLIN MANUFACTURER'S FOR DETAILS,

¢  F.S.B.W. INDICATES COMPLETE PENETRATION FULL STRENGTH BUTT WELD.

« THE CONTRACTOR SHALL PROVIDE AND LEAVE IN PLACE UNTIL PERMANENT BRACING ELEMENTS
ARE CONSTRUCTED, SUCH TEMPORARY BRACING AS IS NECESSARY TO STABILISE THE STRUCTURE
DURING ERECTION,

¢ ROOF AND/OR WALL SHEETING SHALL BE FIXED TO PURLINS OR GIRTS IN ACCORDANCE WITH
MANUFACTURER'S SPECIFICATIONS,

¢ CAP HOLLOW SECTIONS WITH 3mm END PLATES, UNO,

« FOR GALVANISED COATINGS, REPAIR DAMAGE AND SITE WELDS WITH TWO COATS OF TWO PACK
EPOXY POLYAMIDE ZINC-RICH PAINT CONTAINING A MINIMUM 92% ZINC DUST IN THE DRY FILM.

¢« GROUT UNDER BASEPLATES TO BE HIGH STRENGTH CEMENTITIOUS, NON-SHRINK MASTERFLOW 870
or EQUIVALENT, UNO,

 

This drawing is not to be copied or amended without written
permission fram Rienmoc Consulting Engineers

RIENMAC eryit

A.B.N. 52 010 666 430 A.C.N.

O10 666 430

CONSULTING CIVIL €&
STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR,
SAINT CIRINO,

[37 BRISBANE ROAD,

(PO BOx |44)
MOOLOOLABA QLD 4557

P:- (07) 5478 250
F

 

 

(07) 5444 |I5q
- info@rienmac,biz|

[email protected]!
Web:- www.rienmac bi:

 

CLIENT:

GEOFF CONNAN

PROJECT:

PROPOSED DUPLEX

38 ELANDA STREET

SUNSHINE BEACH @LD 4567

REAL PROPERTY DESCRIPTION ¢ COUNCIL:

LOT 158

COUNTY OF MARCH, PARISH OF WEYBA

NOOSA SHIRE COUNCIL
DRAWING TITLE:

GENERAL NOTES
CONCRETE NOTES

 

Designed: PLR

Drawn:

LR

 

SCALES:

 

Engineer: PLR

DATE: 15 NOV Ié

 

16436

JOB NUMBER

SI

DWG No.

 

Pl

ISSUE

 

 

PETER RIENECKER - RPEQ 2088 | | DO NOT SCALE OFF DRAWINGS, | A3

 

 

 

SHEET Il OF 13

 

CHECKED:

PLR

 

 

Page 12

SHEAR CAPACITY

 

 

 

 

 

     

 

 

 

 

 

 

TABLE 8.18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

           

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

RA FTERS, JO| STS or TRUSSES (kN) ( Ch) prywoop SHALL BE NAILED TO FRAME USING 30x2.80 FLATHEAD NAILS OR EQUIVALENT. >)
TO BRAC | NG WAL L Unseasoned Seasoned FOR METHOD A, MI2 RODS SHALL BE USED AT EACH END OF SHEATHED SECTION TOP PLATE TO BOTTOM
JAE REE AT ODEN Timber Timber PLATE/FLOOR FRAME, METHOD B HAS NO RODS BUT SHEATHING SHALL BE NAILED TO TOP AND BOTTOM PLATES
AND ANY HORIZONTAL JOINTS @50mm CENTRES.
TAB L E 8 . 22 J2 | 3B | J4 JD4 | JD5) JDe MINIMUM PLYWOOD THICKNESS (mm) BRACING
Z HORIZONTAL BUTT JOINTS PERMITTED, PROVIDED NAIL CAPACITY
(— (b,) TRUSSED ROOFS BOLTS FIXED TO NOGGING AT S = [50mm CENTRES FOR METHOD A, (kN/m)
NAILS OR SCREWS THROUGH THE TOP PLATE SHALL BE or S = 50mm CENTRES FOR METHOD B. STRESS STUD SPACING
PLACED IN HOLES THAT PERMIT FREE VERTICAL MIO 64/41 |26 143 130] 20 150 50 GRADE (mm)
MOVEMENT OF THE TRUSSES, PROVIDE CLEARANCE : : : : : : ) i. 450 600
ste alle
90x35mm F& NOGGING (ONE BOLT) WHERE ROOF |S MI2 7.6 | 4.9 | 3.1 5 36 25 6 7 a
|20x35mm F& NOGGING (TWO BOLTS) TRUSSED, s 5 Fil 6 7
2/MI0} 12 8 51 18.4 | 5.9 4 2 8 Fld 4 6 neNoD
BRACING WALL. | 9ymI2]} 13. | 4.3 ]61 |as |7 44 as fa7 4 45 6A
LAA BATTEN SCREWS FASTENER SPACING, S (mm) METHOD Bi
6.0
I/No 14 48 135/25 135 |25 18 TOP AND BOTTOM PLATE:
< . . . , . . - METHOD A 150
TYPE I7 - METHOD B 50
Ne 9.7 | 6.9 74.9 16.9 | 4.9 3.6 VERTICAL EDGES 150
3/No 14 {3 93166 194.8 | 74 5.4 f i INTERMEDIATE STUDS 300
SCREWS or BOLTS AS TYPE 17 SHEATHED PANELS SHALL BE
PER TABLE. CONNECTED TO SUBFLOOR,
FRAMING ANCHORS (LEGS
Ror BEI) 2nd oe Mega a our. 2 te
NAILS EACH FACE, END OF SHEATHED SECTION.
(2) NAILING PLATES OR FRAMING ANCHOR NAILS
(LEGS NOT BENT) TO EITHER END OF METHOD A METHOD B
NOGGING 6/2.8mm NAILS EACH FACE 4/3.050| 5.0 | 3.6 | 2.5 | 3.6 3.0 2.2 NOTE: FOR PLYWOOD FIXED TO BOTH SIDES OF THE WALL, SEE
OR 2/No 14 TYPE I7 BATTEN SCREWS : 1
EITHER END, 6/3.050] 6.6 |4.7]3.4 15.0 | 4.2] 3.1 (CLAUSE 8.3.6.5. D)
*oxpomm NOGGING. 1473.33] 5.6 | 4.0/2.8 | 4.0 |33] 25 PLY BRACING WALL DETAILS a
6/3,330 7.4 15.3 )3.7 15.5 | 46 3.5 RIENMAC PTY LTD
BOLTS THE BOTTOM OF ALL BRACING WALLS ARE TO BE ABN. 52 010 666 430 A.C.N. 010 666 430
FIXED TO THE FLOOR FRAMING AS PER TABLE 51a AANEEeS
Mio 64 |4l [26 [4.3 | 3.0] 2.0 6.23 AND 8.24 OF ASI684.2. SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR, P:- (07) 5478 250
MI2 7.6 | 4.9 | 3.1 5.1 3.6 2.5 SAINT CIRINO, - (07) 5444 II5
Mé | 13 |80/51 |84 |5.9] 4.0 (PO BOX (aa) Emails~ info@rienmoc bit
MOOLOOLABA QLD 4557 __Web:- i bi
BATTEN SCREWS ee CONNAN jeb:- _www,rienmac
BRACING WALL. AS PER TABLE. Net 9.7 16.9149 16.9 | 4.9} 3.46 prolrcr.
PROPOSED DUPLEX
ne IB |9.2)66 198 |7.4] 5.4
r 38 ELANDA STREET
(Ff) RAFTERS FOR CEILING SUNSHINE BEACH @LD 4567
“OSTS. REAL PROPERTY DESCRIPTION # COUNCIL:
LOT 158
COUNTY OF MARCH, PARISH OF WEYBA
FRAMING ANCHOR (LEGS NOOSA SHIRE COUNCIL
NOT BENT) 6/2.8mmo DRAWING TITLE:
NAILS EACH FACE, BRACING ¢ TIEDOWN DETAILS
65 146133 149 |4 3 | Designed: PLR Drawn: LR
SCALES:
S&S Engineer: PLR |DATE: 15 NOV |6
BRACING WALL. this drauing i not to be cooied ded without weit SI 2
/ permission from Riewnoe Corsulting Engineers | JOB NUMBER DWG No. | ISSUE
PETER RIENECKER - RPEQ 2088 DO NOT SCALE OFF DRAWINGS. | A3 |SHEET 12 OF 13 |CHECKED: PLR

 

 

 

 

 

 

 

Page 13

 

APPENDIX A REQUIREMENTS FOR SITE DRAINAGE,

 

 

 

 

 

 

 

 

APPENDIX B SITE PREPARATION AND EARTHWORKS.

 

 

 

 
 

  

 

 

Q
js © TTT 3
Gz = BANK WIDTH [800mm OR AS FOLLOWS FOR VARIOUS SOIL TYPES
y “ &/s! - WEATHERED ROCK : WELL GRADED GRANULAR FILLS.
Ne ™ - CLAYS : SILTY, SANDY AND GRAVELLY CLAYS
- SILTS + SANDS AND SOFT CLAYS
~ \ Y
TO OUTFALL
= \/
g kT
~,
aa /
he COMPACTED
vu TERIAL
TO OUTFALL _ FLOOR SLAB
VY “ CHECK EROSION s =
B. DRAINAGE LAYOUT FOR WET SITE. as
TO OUTFALL TO OUTFALL _

 

EARTH DRAIN REQUIRED IF

A. TYPICAL DRAINAGE LAYOUT FACE IS LIKELY TO SCOUR

    

 

 

ST

 

 

 

 

“S—__EARTH DRAIN
(FALL 1:100)
GROUND OUTSIDE
RESIDENCE TO FALL TO
EARTH DRAIN AT 1:10.

 

 

 

SLAB CAST ABOVE GROUND
LEVEL TO SUIT DRAINAGE
CONDITIONS AND FALLS TO
SEWERS AS PER LOCAL
AUTHORITY ORDINANCES.

 

L TO OUTFALL
Cc. DRAINAGE LAYOUT FOR CUT & FILL SITE

NOTES:-

 

THE SITE MUST BE SO GRADED AND DRAINED THAT THE WATER IS SHED FROM THE LDING PLATFORM IN

ACCORDANCE WITH THE ABOVE PRINCIPLES

 

2. PROVISION OF PAVING, SURFACE GUTTERING OR UNDERGROUND PIPING WILL ALL ASSIST IN ACHIEVING GOOD

DRAINAGE.

 

3. GOOD DRAINAGE MUST BE MAINTAINED THROUGHOUT CONSTRUCTION AS WELL AS AFTER PRACTICAL COMPLETION

4. DRAINAGE MUST NOT BE DIRECTED AT AN ADJACENT LOT IN A CONCENTRATED FORM.

 

 

—

DRAINAGE SYSTEM

d nee APP E
WHERE ‘d! EXCEEDS 1200mm, REFER TO ENGINEER FOR REFER APPENDIX A

RE-APPRAISAL OF FOOTING AND SLAB DESIGN.

 

ERE BANK WIDTHS SPECI

 

ED ABOVE CAN NOT BE ATTAINED DUE TO SITE CONSTRAINTS

 

NOTES:-

    

THE CONFINES OF THE BUILDING SITE ARE TO BE S
HE BUILDING AREA. GRUB HOLES ARE TO BE BACK

 

LLED AND COMPACTED AS INDICAT

2

 
 
 
 

2. WHERE SLAB AND FOOTINGS ARE TO BE FOUNDED IN FILL, BUILDING PLATFORMS SHALL BUILT
UP IN LAYERS AND COMPACTED TO ATTAIN A MINIMUM UNIFORM FIELD DENSITY OF 98% STANDARD
COMPACTION FOR COHESIVE FILL MATERIAL AND A MINIMUM DENSITY INDEX OF 70% RELATIVE TO TEST
E6.| FOR GRANULAR (NON-COHESIVE) FILL MATERIAL

 
 

3. SOIL MOISTURE CONTENT SHOULD D NEAR OPTIMUM DURING COMPACTION
DRUM ROLLERS MAY BE USED FOR GRANULAR FILLS, VIBRATING SHEEPFOOT ROLLERS ARE
RECOMMENDED FOR CLAYS

 

 

THE QUALITY OF COMPAC
=R'S RESPONSIB
THE QUALITY AND DEGREE OF COMPACTION OF
ACROSS THE WHOLE PLATFORM.

   

  

 

This drawing is not to be copied or amended without written
permission from Rienmac Consulting Engineers

RIENMAC eryit

A.BN. 52 010 666 430 A.C.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS

SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR,

 

P:- (07) 5478 250d

 

 

 

SAINT CIRINO, F:- (07) 5444 (158
137 BRISBANE ROAD, - info@rienmac, biz
(PO BOX 149) info@rienmac,ne'
MOOLOOLABA QLD 4557 Web:— www ,rienmac, bi:
CLIENT:

GEOFF CONNAN

PROJECT:

PROPOSED DUPLEX

38 ELANDA STREET
SUNSHINE BEACH @LD 4567

REAL PROPERTY DESCRIPTION # COUNCIL:
LOT 158

COUNTY OF MARCH, PARISH OF WEYBA
NOOSA SHIRE COUNCIL
DRAWING TITLE:

APPENDIX A @ B

 

 

 

 

 

 

 

 

PETER RIENECKER - RPEQ 2088 | | po nor scate or pRaWINGS. | A3

 

 

Designed: PLR Drawn: LR

SCALES:

Engineer: PLR |DATE: 15 NOV Ié
16436 513] PI

JOB NUMBER DWG No. | ISSUE

SHEET 13 OF 13 |CHECKED: PLR

 

 

 

Used in these records

About this file

File size
1.6 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

16436 - 16Nov16.pdf · 1.6 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.