Council archive · source document
16436 - 16Nov16 · MCU16/0049
Attached to the e-mail Response to Information Request Part 1 MCU16/0049 & OPW16/0109.
Od
150.
300 DEERP-——_1
RUBBLE PIT.
500 SQ
Nees DRAIN LINE
EACH WAY
SL yorosranic VALVE
MAI!
N DR
AIN DETAIL
WATER LEVEL
SI2 BARS @300
CRS EACH WAY.
STEP
DETAIL
(INDICATIVE ONLY)
PROVIDE 2/512 HOR 1200 LONG TOP ¢ BOTTOM
AT SKIMMER BOX ¢ SIMILAR OPENINGS.
——
SKIMMER BOX
Lo
HYDROSTATIC VALVE TO BE __\
INSTALLED AT LOWEST POINT.
2/S|2 BARS EACH SIDE
SKIMMER
FILTER DISCHARGE TO COUNCIL 1.
REQUIREMENTS.
PUMP
MAIN DRAIN
TO POOL
INLETS
DIAGRAMMATIC WATER
POOL CONSTRUCTION SPECIFICATION
WORKMANSHIP € MATERIALS TO BE IN ACCORDANCE WITH AS2783 CONCRETE SWIMMING
POOL CODE AND LOCAL AUTHORITY'S REQUIREMENTS.
2. POOL FILLING # SOIL BACKFILLING NOT TO BE CARRIED OUT UNTIL WALLS &¢ FLOOR HAVE
REACHED DESIGN STRENGTH.
3. 50mm LAYER OF 22mm GRAVEL TO BE PLACED UNDER POOL FLOOR.
4, ALL CONCRETE ON PLAN TO BE 300mm RADIUS UNLESS NOTED OTHERNISE.
5. DEEP END TO HAVE AT LEAST 0.3m OF FIRM, NATURAL SOIL OR EQUIVALENT RETAINING
WALL, ETC AS SUPPORT.
Ss
SUPPORTING SOIL TO BE SOUND NATURAL SOIL OR WELL COMPACTED FILLING WITH
BEARING CAPACITY AT ANY DEPTH NOT LESS THAN |00kPa.
RETICULATION :
THIS DESIGN APPLIES FOR FLAT SITES AND UNIFORM GROUND CONDITIONS ONLY. ON
SLOPING SITES PROVIDE RETAINING WALLS OR CUT/FILL WITH CONTROLLED COMPACTION
OF FILLING TO MATCH NATURAL SOIL CONDITIONS. ON CUT @ FILL SITES A BEAM NOT
LESS THAN TWICE THE DEPTH OF THE FILL AT THE POOL |S REQUIRED BEYOND THE POOL
WALL.
8. DESIGN TO BE MODIFIED IF EXCESS GROUND WATER IS ENCOUNTERED DURING
EXCAVATION.
9. ALL DIMENSIONS ON SITE PLAN SHOWING THE POSITION OF THE POOL ARE TO THE WATER
FACE.
POOL OWNER TO BE INFORMED THAT AN ELEMENT OF RISK TO THE POOL STRUCTURE |S
INVOLVED IF THE POOL IS EMPTIED.
ALL DETAILS TO BE IN
ACCORDANCE WITH
BESSER SPECIFICATIONS.
BLOCK POOL SPECIFICATIONS
ALL WORKMANSHIP AND MATERIALS SHALL BE IN
ACCORDANCE WITH THE 5.A.A, CODES:
* AS53600 CONCRETE STRUCTURES.
* AS53700 MASONRY CODE BLOCKWORK.
BLOCKS TO BE 20.18, 20.48, 20.21 AS SUPPLIED
BY BESSER (QLD) LIMITED.
ULTIMATE COMPRESSIVE STRENGTH OF CONCRETE
(Fic) TO BE 32MPa, FLOOR CONCRETE TO BE
VIBRATED.
FLOOR CONCRETE TO BE [50 THICK.
I50 THICK POOL BASE.
800 MAX
512 BARS @200 CRS MAX
EACH WAY CENTRAL IN
‘
w
S
S
N
S
S
Vt
7 A
20-18
RIENMAC eryit
A.BN. 52 010 666 430 A.C.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS
SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR,
GROUND
20-48-—~s LEVEL
RE.
Mx
| ~NI2 VER BARS CENTRAL P:- (07) 5478 250
IN’7] fon poo. DEPTS UP 137 BRISBANE. ROAD, Email ubrineec i
Ler cee FOR POOL DEPTHS (OODOLASS cup 4667 we Suea'tnee a
UP TO 100mm. GEOFF CONNAN
piey Nip HOR BARS @200 CRS PROJECT:
TO BLOCKWALL. LAP PROPOSED DUPLEX
450 WHERE REQ'D AND
HYDROSTATIC VALVE
2 EXTRA 512 TH77] AT CORNERS
POOL SHELL. LAP 600 ‘ 38 ELANDA STREET
WHERE REQ'D. LONGITUDINALLY. SUNSHINE BEACH QLD 4567
| 20-18 REAL PROPERTY DESCRIPTION # COUNCIL:
LOT 158
COUNTY OF MARCH, PARISH OF WEYBA
wo NOOSA SHIRE COUNCIL
TF .
KKK 225 DETAILS.
PROVIDE Nié TIE BARS TO
POOL BASE REINF'T AT
EACH VER BAR. LAP 600 Designed: PLR Drawn: LR
| WITH POOL REINF'T AND 500
| WITH WALL REINF'T, SCALES: 1:20
: TYPICAL IN-GROUND BLOCK = Eero
DOL DEeTAU 164326 | SIO) Pl
UVUE VETAIL perniasion fram Renae Coraultig Engreers “| JOB NUMBER DWG No. | ISSUE
PETER RIENECKER - RPEQ 2088 | DO NOT SCALE OFF DRAWINGS. | A3 |SHEET 10 OF 13 |CHECKED: PLR
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
16436 - 16Nov16.pdfRelated documentApplication case desk ↗
16436 - 16Nov16.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.6 MB (small file)
- File type
No other editions are linked here.