APPENDIX A REQUIREMENTS FOR SITE DRAINAGE,
APPENDIX B SITE PREPARATION AND EARTHWORKS.
Q
js © TTT 3
Gz = BANK WIDTH [800mm OR AS FOLLOWS FOR VARIOUS SOIL TYPES
y “ &/s! - WEATHERED ROCK : WELL GRADED GRANULAR FILLS.
Ne ™ - CLAYS : SILTY, SANDY AND GRAVELLY CLAYS
- SILTS + SANDS AND SOFT CLAYS
~ \ Y
TO OUTFALL
= \/
g kT
~,
aa /
he COMPACTED
vu TERIAL
TO OUTFALL _ FLOOR SLAB
VY “ CHECK EROSION s =
B. DRAINAGE LAYOUT FOR WET SITE. as
TO OUTFALL TO OUTFALL _
EARTH DRAIN REQUIRED IF
A. TYPICAL DRAINAGE LAYOUT FACE IS LIKELY TO SCOUR
ST
“S—__EARTH DRAIN
(FALL 1:100)
GROUND OUTSIDE
RESIDENCE TO FALL TO
EARTH DRAIN AT 1:10.
SLAB CAST ABOVE GROUND
LEVEL TO SUIT DRAINAGE
CONDITIONS AND FALLS TO
SEWERS AS PER LOCAL
AUTHORITY ORDINANCES.
L TO OUTFALL
Cc. DRAINAGE LAYOUT FOR CUT & FILL SITE
NOTES:-
THE SITE MUST BE SO GRADED AND DRAINED THAT THE WATER IS SHED FROM THE LDING PLATFORM IN
ACCORDANCE WITH THE ABOVE PRINCIPLES
2. PROVISION OF PAVING, SURFACE GUTTERING OR UNDERGROUND PIPING WILL ALL ASSIST IN ACHIEVING GOOD
DRAINAGE.
3. GOOD DRAINAGE MUST BE MAINTAINED THROUGHOUT CONSTRUCTION AS WELL AS AFTER PRACTICAL COMPLETION
4. DRAINAGE MUST NOT BE DIRECTED AT AN ADJACENT LOT IN A CONCENTRATED FORM.
—
DRAINAGE SYSTEM
d nee APP E
WHERE ‘d! EXCEEDS 1200mm, REFER TO ENGINEER FOR REFER APPENDIX A
RE-APPRAISAL OF FOOTING AND SLAB DESIGN.
ERE BANK WIDTHS SPECI
ED ABOVE CAN NOT BE ATTAINED DUE TO SITE CONSTRAINTS
NOTES:-
THE CONFINES OF THE BUILDING SITE ARE TO BE S
HE BUILDING AREA. GRUB HOLES ARE TO BE BACK
LLED AND COMPACTED AS INDICAT
2
2. WHERE SLAB AND FOOTINGS ARE TO BE FOUNDED IN FILL, BUILDING PLATFORMS SHALL BUILT
UP IN LAYERS AND COMPACTED TO ATTAIN A MINIMUM UNIFORM FIELD DENSITY OF 98% STANDARD
COMPACTION FOR COHESIVE FILL MATERIAL AND A MINIMUM DENSITY INDEX OF 70% RELATIVE TO TEST
E6.| FOR GRANULAR (NON-COHESIVE) FILL MATERIAL
3. SOIL MOISTURE CONTENT SHOULD D NEAR OPTIMUM DURING COMPACTION
DRUM ROLLERS MAY BE USED FOR GRANULAR FILLS, VIBRATING SHEEPFOOT ROLLERS ARE
RECOMMENDED FOR CLAYS
THE QUALITY OF COMPAC
=R'S RESPONSIB
THE QUALITY AND DEGREE OF COMPACTION OF
ACROSS THE WHOLE PLATFORM.
This drawing is not to be copied or amended without written
permission from Rienmac Consulting Engineers
RIENMAC eryit
A.BN. 52 010 666 430 A.C.N. 010 666 430
CONSULTING CIVIL &
STRUCTURAL ENGINEERS
SUNSHINE COAST OFFICE:
SUITE 5, FIRST FLOOR,
P:- (07) 5478 250d
SAINT CIRINO, F:- (07) 5444 (158
137 BRISBANE ROAD, - info@rienmac, biz
(PO BOX 149) info@rienmac,ne'
MOOLOOLABA QLD 4557 Web:— www ,rienmac, bi:
CLIENT:
GEOFF CONNAN
PROJECT:
PROPOSED DUPLEX
38 ELANDA STREET
SUNSHINE BEACH @LD 4567
REAL PROPERTY DESCRIPTION # COUNCIL:
LOT 158
COUNTY OF MARCH, PARISH OF WEYBA
NOOSA SHIRE COUNCIL
DRAWING TITLE:
APPENDIX A @ B
PETER RIENECKER - RPEQ 2088 | | po nor scate or pRaWINGS. | A3
Designed: PLR Drawn: LR
SCALES:
Engineer: PLR |DATE: 15 NOV Ié
16436 513] PI
JOB NUMBER DWG No. | ISSUE
SHEET 13 OF 13 |CHECKED: PLR
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
16436 - 16Nov16.pdfRelated documentApplication case desk ↗
16436 - 16Nov16.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.6 MB (small file)
- File type
No other editions are linked here.