Original source · versioned page text
RFI - 250624 - 3 Allambi Rise - DA RFI response
Very large file (100 MB): the original may take a few minutes to open or download. The page text below is quick to read.
1 2 3 4 5 6
general items legend
1 1 150
L1 (level) window code. refer to window 20 step up code. note step line 210 400.12
0
0
400.11
w01 (window ref) elevations + door/window occurs on low side of level
399 1 462 1 1 1
hardware schedules high lvl high lvl - 20 mm change 0 400.08
0 400.06 400.07 400.05
Ipb01 material code. refer finishes (cos) check on site
schedule (typical). (mir) mirrored detail site boundary I 43.533 m approx I 90° 00' 00''
(sim) similar detail
' 00 m
dp01 component code.
(part) partial detial
(refer material code for similar)
6
''
I 20 I 21.74
slope greater than 33% past
door/gate code. refer to window 2700 ceiling code site LPOD - refer to civil this line (based on NGL)
° 30
L1 (level) height*
d01 (door/gate ref) elevations + door/window Ipb01 finish** * heights are relative to enginnering design
1.5m setback
app undary
hardware schedules associated finished floor
* refer finishes schedule
rox
2.0m setback
H
o
RL 60.200 spot level SSL xx.xxx structural slab level
b
tos = top of step
site
1300
bos = bottom of step FFL xx.xxx finished floor level
RL = lvl at point (AHD typ)
RL xx.xxx top of wall (surface) level
G tv
bar fridge + 1
general notes dishwasher + zip 100.11
1. all works to be carried out in accordance with the general 1
400.10
construction notes in coversheets of this package. 1
400.04
2. all works to be carried out in accordance with the DA (if required)
and BA including drawings & conditions.
pool
3300
3. handrails are required to all stairways where a change of level of
1000mm or greater occurs as per BCA 2013 Part 3.9.2.4.
4. where boundary locations are not clear, the builder shall arrange skylight over
ack
for survey to locate the boundaries and complete an identification
games room
setb
N survey prior to setting out the new work.
5. contours shown are existing and do not represent finished levels. water tank stn01
6m
FFL 44.800
F
e n
er li
1800
sew
1 1
400.09 400.03
L0
d21
E
spa cold plunge?
1
400.02
lift
0
3170
572
swr
FFL 44.800
1
lift control 400.01
TPZ encroachment of pool
and pool footing - 3.00 sqm
D
L0 L0
1140
M Environmental Management
k
bathroom L0 d23
c
d22
etba
and Conservation easement d25
ms
C
mirror
10.0
arborist to be involved during footing L0 L0
d27 d26
design of pool deck for feedback on
impact on root system pump seat
and gymnasium
sauna wc
''
service
' 00
stn01
° 30
room
4900
e
FFL 44.800
n
er li
wc
2 00
sew
SRZ
I
rox
app
L00
d51 1
46 m
TPZ encroachment of
wine cellar
400.00
tree N.25 house footing - 14.30 sqm
total encroachment L0
1.7
d24
17.30 sqm
I2
B
ary
650
u nd
A
bo
2.0m setback
site
1.5m setback
TPZ - 221sqm total
site boundary I 43.533 m approx I 270° 00' 00''
3060 3590 4000 1880
10 11 12 13 14
1 floor plan - lower level - L0
100.11 1 : 100
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0453
K 02/06/2025 hydraulic coordination 3 Allambi Rise, - general arrangment plans SD 200.00 N SCALE As indicated
L 12/06/2025 DA RFI response - coordination Noosa Heads QLD 4567
A3
lower ground floor plan
M 16/06/2025 hydraulic coordination
N 24/06/2025 DA RFI response
schematic design 1:1 @
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.