Original source · versioned page text
SCG 31131-Civil Issue 6-2022.03.09.pdf
Issue:
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
DEBUILD T/A
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 899
Title:
Project
Date: Drawn Design
Checked: Drg No. Rev.
Rev. - 10.06.16
[OCR of page images]
DRAWING SIZE — At
www.dialbeforeyoudig.com.au
SAY DIAL1100
yy BEFORE YOU DIG
"NE fF
Floor Level 115]
| RL13.47
1B Ae Ln x
) _ — TOU ly 1.5m x 5.9m
<*__79°10'00" 3 of 2 — = ee
HEIGHT DATUM SS i308 95.916 = Tass aes ” one
Lot 1 on RP130594 & Lots 80 & z ae cal a oF
81 on RP71151 *
Level Datum AHD /
Level Origin PSM115316, RL 3.593m a org @TREE 21005 .
Survey information provided by Noosa E OS1010g Lot 80 (#89) ~
Cooloola Land Surveys Pty Ltd | > RP74 151 ME 0.40805 °
Drg No. 21215DET nse 2 wo? a” ” °
$ z 1
% ©) 0.4 .
on 1208 -
So SHED
é % ‘ Cap °.62015 @ @Fic 31019
& _ P26, nro
s + 79°10'08" 106 °
— - ees - —- —- —- a _ - - - - - - - -- -- ---- -@ —-—-—- -9-—_._._ cc ce
* 46.40 Wo hole Qs 95.912 so” a 40.92 Monel
Sewer Man’ a ewer Manhole
1114.47 . 1L13.47 . e et 1113.47 ©
3\(From Unity Water Records) (From Unity Water Records) aa S25 ns aN often, Unity Woter Records) '
ey, ” »” confirm as manhole is full of watey
Lot 81 (#91)
RP71151
!
SW/EX
AA /
Lot 1 (#93) /
"5 RP130594 St
ae sen" eo ae o , im >. |
, RP BOUNDARY . % YY
S,
ES
ee 2501035" 849083
0. dm —_ —_ x || 20.4m I 193m... ~ — — xq 19.3m “ x
Floor Level RL17.14 | Floor Level RL16.57
/ on
82
SP120~._
SITE PLAN — EXISTING SURVEY AND SERVICES PLAN
Scale 1: 200
LEGEND
_---77 INDICATES EXISTING SURFACE CONTOURS Revision | Description ne
8.07 AND LEVELS 10 AHD. issue
ue:
+180 EXISTING SURFACE SPOT LEVELS. FOR APPROVAL
———_ — ——_ INDICATES OVERHEAD ELECTRICITY DO NOT SCALE FROM THIS DRAWING
SUPPLY LINE The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
the written permission of SCG Consulting Engineers.
INDICATES EXISTING SEWER LINE
> Unit 1/11 Project Ave,
S INDICATES SEWER LINE PROPOSED AS Noosa Heads
NOTED MIN 1 IN 60 FALL UNLESS NOTED Ph (07) 5455 5604
OTHERWISE 5 chore con
——_ w—_—_ INDICATES WATER MAIN APPROX KE -
ALIGNMENT, BUILDER TO CONFIRM EXACT —— Title:
LOCATION PRIOR TO WORKS EX. SWPT EXISTING STORMWATER PIT EXISTING SURVEY PLAN
RC. HW. — REINFORCED CONCRETE HEADWALL
EX. SMH — EXISTING SEWER MANHOLE
E.0.B. EXISTING EDGE OF BITUMEN
ee INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
K &C EXISTING KERB & CHANNEL Project
sw INDICATES STORMWATER DRAIN PROPOSED NS.L NATURAL SURFACE LEVEL 89-93 Eumundi Noosa Rd
AS NOTED MIN 1 IN 100 FALL UNLESS lg FIRE HYDRANT ,
NOTED OTHERWISE TP TELSTRA PIT NOOSAVILLE
EP. ELECTRICAL POWER POLE
— sw/ex—————_ INDICATES STORMWATER DRAIN EXISTING KERB EXISTING KERBING Dale: Way 21 Drawn 2 | Design op
AS NOTED Checked: Drg No Rev.
Srchorisn |) |OLTS1—-C1.1)
Preview the original
The page text is free to read. Previews and downloads of original files need an account.
Log in to previewLog in to download the original (SCG 31131-Civil Issue 6-2022.03.09.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.