Council archive · source document
Atachment A - proposal plans unit 17 · MCU20/0130
Plans and drawings: the text below has words only, no drawings.
GENERAL NOTES:
DRAWINGS PROVIDED ARE FOR ARCHITECTURAL DESIGN PURPOSES ONLY. CONSTRUCTION
MUST REFER TO STRUCTURAL ENGINEERING DOCUMENTATION AND LOCAL BUILDING CERTIFIER
FOR CORRECT BUILDING METHOD, MATERIALS ETC. IN NO WAY ARE THESE DRAWINGS TO BE
USED FOR CONSTRUCTION.
DRAWINGS TO BE READ IN CONJUNCTION WITH OTHER CONSULTANTS DOCUMENTATION.
REFER ANY DISCREPANCIES TO THE RELEVANT CONSULTANT FOR WRITTEN DIRECTION.
THIS SET OF PLANS IS SUFFICIENT TO OBTAIN A BUILDING PERMIT; HOWEVER, ALL
MATERIALS AND METHODS OF CONSTRUCTION NECESSARY TO COMPLETE THE PROJECT
ARE NOT NECESSARILY DESCRIBED. THE PLANS DELINEATE AND DESCRIBE ONLY LOCATIONS,
DIMENSIONS, TYPES OF MATERIALS AND GENERAL METHODS OF ASSEMBLING OR FASTENING
AND OTHER CONSULTANTS DOCUMENTATION SPECIFIES THE PARTICULAR PRODUCTS,
MATERIALS AND TYPE OF CONSTRUCTION RECOMMENDED FOR THIS DESIGN.
DIMENSIONS TAKE PRECEDENCE OVER SCALED MEASUREMENTS. DETAILS AND SECTIONS ON
THE DRAWINGS ARE SHOWN AT SPECIFIC LOCATIONS AND ARE INTENDED TO SHOW GENERAL
REQUIREMENTS THROUGHOUT. DETAILS NOTED "TYPICAL" IMPLY ALL LIKE CONDITIONS
TREATED SIMILARLY, UNLESS NOTED OTHERWISE. THE ARCHITECTURAL DETAILS SHOWN ARE
INTENDED TO FURTHER ILLUSTRATE THE VISUAL DESIGN CONCEPT AND THE MINIMUM
RECOMMENDED WEATHER PROTECTION FOR THIS PROJECT. BUILDING CODE REQUIREMENTS,
OTHER CONSULTANTS DOCUMENTATION AND PRODUCT MANUFACTURER'S WRITTEN
INSTRUCTIONS SHALL ALSO BE CONSIDERED IN ORDER TO COMPLETE THE CONSTRUCTION OF
THE DETAILS, AND IN SOME CASES MAY SUPERSEDE THE DETAILS.
THE BUILDER AND ALL SUB CONTRACTORS SHALL REVIEW THE FULL CONTENT OF THE PLANS
FOR DISCREPANCIES AND OMISSIONS PRIOR TO COMMENCEMENT OF WORK. THE BUILDER AND
SUB CONTRACTORS SHALL BE RESPONSIBLE FOR ANY WORK NOT IN CONFORMANCE WITH THE
PLANS OR IN CONFLICT WITH ANY RELEVANT CODE. Subject Site
ALL CONSTRUCTION SHALL COMPLY WITH THE MOST STRINGENT REQUIREMENTS OF ALL
CURRENT APPLICABLE STATE AND COUNCIL LAWS, RULE, CODES AND REGULATIONS. IF THE
BUILDER OR ANY SUB CONTRACTOR PERFORMS ANY WORK IN CONFLICT WITH THE ABOVE
MENTIONED LAWS, THEN THE CONTRACTOR IN VIOLATION SHALL BEAR ALL COSTS OF
REPAIR ARISING OUT OF THE NON-CONFORMING WORK.
THE BUILDER IS RESPONSIBLE TO CHECK ALL EXISTING SERVICES PRIOR TO BEGINNING
CONSTRUCTION. BUILDER TO VERIFY PROPERTY BOUNDARIES AND BUILDING LINES PRIOR
TO COMMENCEMENT OF WORKS IN ASSOCIATION WITH APPROVALS.
ALL SERVICES INCLUDING FIRE FIGHTING SERVICES, OCCUPANT WARNING SYSTEMS,
LIGHTING, POWER, WATER SUPPLY, SANITARY DRAINAGE, STORMWATER, MECHANICAL
VENTILATION AND AIR CONDITIONING TO BE IN ACCORDANCE WITH RELEVANT
CONSULTANTS DETAILS.
ALL STRUCTURAL ELEMENTS TO BE IN ACCORDANCE WITH ENGINEERS DESIGN AND DETAILS.
WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH RELEVANT CURRENT,
SAA CODES AND STATUTORY AUTHORITIES REQUIREMENTS.
ANY ADDITION OR DELETION OR CHANGE IN THE SCOPE OF WORK DESCRIBED BY THE PLANS
SHALL BE BY WRITTEN APPROVAL TO THE RELEVANT CONSULTANT.
EXISTING SITE CONDITIONS & PROPOSED DESIGN TO BE CONFIRMED ON SITE WITH BUILDER &
ENGINEER PRIOR TO CONSTRUCTION OR ORDERING OF ANY MATERIALS.
ALL DIMENSIONS & HEIGHTS TO BE CONFIRMED ON SITE WITH BUILDER PRIOR TO CONSTRUCTION
OR ORDERING OF ANY MATERAILS. RETAINING WALL HEIGHTS TO BE CONFIRMED ON SITE WITH
ENGINEER & BUILDER PRIOR TO CONSTRUCTION.
COLLINS BUILDING DESIGNS IS IN NO WAY RESPONSIBLE FOR ESTIMATIONS MADE FROM THESE
DRAWINGS THAT DIFFER FROM ACTUAL COSTINGS. BUILDER IS RESPONSIBLE FOR ALL COSTING
VARIATIONS AND EXTRAS THAT ARISE FROM CONSTRUCTION.
IT IS THE RESPONSIBILITY OF THE BUILDER TO ENSURE ALL RELEVANT TRADES HAVE UP TO DATE
DRAWINGS. NOTIFY ALL PARTIES IN WRITING OF ANY/ALL CHANGES MADE FROM ANY OTHER
TRADE AT ANY TIME AS SOON AS A CHANGE IS MADE.
ALL CADASTRAL/TOPOGRAPHY DATA (RLs,BOUNDARIES,CONTOURS,SERVICES ETC) SHOWEN HAS
BEEN PROVIDED FROM INTERNET MAPPING SITES AND IS NOT ACCURATE. IT IS THE
RESPONSABILITY OF THE BUILDER TO ENSURE A LICENCED SURVEYOR HAS CARRIED OUT A
SURVEY TO ENSURE CORRECT SETOUT,HEIGHTS,DEPTHS ARE ACCURATE AND COMPLY WITH
LOCAL AND STATE LAWS & REQUIREMENTS. THE BUILDER IS TO ENSURE THE SURVEY IS
PROVIDED TO COLLINS BUILDING DESIGNS & ALL OTHER SUB CONTRACTORS/PROFFESIONALS
ALONG WITH ANY DESCREPANCIES IN WRITING PRIOR TO ANY CONSTRUCTION.
ALL CABINETRY SHOWN ARE A CONCEPT DESIGN ONLY AND IT IS THE RESPONSIBILTY OF THE
BUILDER & CABINET MAKER TO CARRY OUT A CHECK MEASURE PRIOR TO ANY CONSTRUCTION.
WINDOW & DOOR SCHEDULE IS A GUIDE FOR QUOTING PURPOSES ONLY AND IS THE
RESPONSIBILTY OF THE BUILDER AND WINDWO/DOOR SUPPLIER TO ENSURE A CHECK MEASURE
IS CARRIED OUT PRIOR TO ANY ORDERING OR MANUFACTURING.
Design Information Concept
• Address: 11 Bartlett Street, Noosaville 4566
• Lot & Plan: Lot 47 Plan RP173566 Proposed Industrial Units 16 & 17
• Local Government (Council): Noosa Shire
collinsbuildingdesigns.com.au • Industry Zone 11 Bartlett St, Noosaville
Date: 07.09.2020
Mob: 0474 141 348
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 7 pages
Page 2
b o u n d a r y
r y
a
d
n
Lot 1 Lot 2 Lot 3 Lot 4 Lot 5
o u
SP105411 SP105411 SP105411 SP105411 SP105411
185m2 370m2 185m2 370m2 557m2 Landscaping
b
b
o
existing industrial units u
n
d
a
r
y Landscaping
Landscaping
5400 5400
2500
2500
2500
2500
2500
2500
2500
2500
5400 Typ'
Typ'
Typ'
Typ'
Typ'
Typ'
Typ'
Typ'
Refuse Area
2500
Typ'
2500
Typ'
2500
Typ'
500
5400 5400 5400
5400 5400 5400
5400
5400
2700
Typ'
Disabled Disabled Disabled Disabled Disabled
Landscaping Landscaping Landscaping Landscaping
r y
r y
a
a
d
Lot 6 Lot 7
d
n
SP190837 SP190837
n
o u
198m2 1744m2
o u
b
existing industrial units
b
existing bowling centre
b o u n d a r y
190 10120 190 9540 190 9540 190 9540 190 9540 190 87420 48500 190
5766 98110 2500
Concept
Do not scale off this drawing. DRAWING REVISIONS Drawing Title: Project:
Check all dimensions on site. REV. DATE DESCRIPTION
Existing Site Plan Proposed Industrial Units 16 & 17
11 Bartlett St, Noosaville
All drawings are copyright and Orientation:
are owned and controlled by Client:
Collins Building Designs. All Robilliard Building & Scale: 1 : 350 @ A3 Drawing No:
Building works must comply
with current B.C.A and S.A.A. [email protected]
Mob: 0474 141 348
Design Date: 07.09.2020 Rev: A04_ A102
Page 3
b o u n d a r y
r y
a
d
n
Lot 1 Lot 2 Lot 3 Lot 4 Lot 5
o u
SP105411 SP105411 SP105411 SP105411 SP105411
185m2 370m2 185m2 370m2 557m2 Landscaping
b
b
o
existing industrial units u
n
d
a
r
y Landscaping
Landscaping
5400 5400
2500
2500
2500
2500
2500
2500
2500
2500
Typ'
Typ'
Typ'
Typ'
Typ'
Typ'
Typ'
Typ'
5400
Refuse Area
2500
Typ'
b o u n d a r y
2500
Typ'
500
5400 5400 5400 5400 5400
2500
5400
Typ'
5400
5400
2700
Typ'
Disabled Disabled Disabled Disabled Disabled
Landscaping Landscaping Landscaping Landscaping
r y
r y
a
a
d
d
n
12 13 14 15 16 17
n
o u
Lot 6 193m2 193m2 193m2 193m2 759m2 193m2
o u
SP190837
b
198m2
b
existing industrial units proposed industrial units
b o u n d a r y
190 10120 190 9540 190 9540 190 9540 190 9540 190 38710 190 9600 190
5766 98110 2500
Concept
Do not scale off this drawing. DRAWING REVISIONS Drawing Title: Project:
Check all dimensions on site. REV. DATE DESCRIPTION
Proposed Site Plan Proposed Industrial Units 16 & 17
11 Bartlett St, Noosaville
All drawings are copyright and Orientation:
are owned and controlled by Client:
Collins Building Designs. All Robilliard Building & Scale: 1 : 350 @ A3 Drawing No:
Building works must comply
with current B.C.A and S.A.A. [email protected]
Mob: 0474 141 348
Design Date: 07.09.2020 Rev: A04_ A103
Page 4
portions of wall to be removed to make
way for new front facade for each unit.
r y
e
e
r y
fic
fic
Lot 7
of
of
a
SP190837
a
d
1744m2
d
n
12 13 14 15
n
o u
Lot 6 193m2 193m2 193m2 193m2 serving
o u
SP190837
b
198m2
existing
b
industrial kitchen existing bowling lanes to be removed
units
toilets
b o u n d a r y
190 10120 190 9540 19270
190 9540 190 9540 190 9540 190 67960 48500 190
5766 98110 2500
Existing & Demolition Floor Plan
1 1 : 350
fire hose reel
fire hose reel proposed "typical front facade'' proposed roller door proposed "typical front facade''
r y
r y
a
a
d
d
n
Lot 6 12 13 14 15 16 17
n
o u
SP190837 193m2 193m2 193m2 193m2 759m2 193m2
o u
198m2
b
existing
b
industrial proposed 90/90/90 fire
units wall. 140x45 LVL studs &
proposed "typical proposed "typical plates @ 600mm centre
bathroom & kitchenette" bathroom & kitchenette" with 2 layers of fyrecheck
plasterboard to both sides.
Refer engineering for
correct details and to
comply with BCA part 3.7.1
Fire exit doors with Signange in accordance
with the Building Fire Saftey Regulation
b o u n d a r y
190 10120 190 9540 19270
190 9540 190 9540 190 9540 190 38710 190 9600 190
5766 98110 2500
NOTES
1. Proposed walls to comply with BCA, Part 3.7.1
2. Seperating walls to be continuous from the slab to the
underside of a non-combustible roof covering Proposed Floor Plan
3.
4.
Sound seperation to compy with BCA, Part 3.8.6
Refer engineering for all specifc details and correct
2 1 : 350
building methods and materials to be used.
Concept
Do not scale off this drawing. DRAWING REVISIONS Drawing Title: Project:
Check all dimensions on site. REV. DATE DESCRIPTION
Existing & Proposed Floor Plans Proposed Industrial Units 16 & 17
11 Bartlett St, Noosaville
All drawings are copyright and Orientation:
are owned and controlled by Client:
Collins Building Designs. All Robilliard Building & Scale: 1 : 350 @ A3 Drawing No:
Building works must comply
with current B.C.A and S.A.A. [email protected]
Mob: 0474 141 348
Design Date: 07.09.2020 Rev: A04_ A104
Page 5
Inculde exhaust fan for mechanial
ventilation, exhaust to exterior 600 2790
Amenities to comply with AS1428.1 90 1600 1100
folding shower seat
90
90
920
400
490
shower grab rail
1600
S1
500
2490
2490
2400
A105 E1
1970
600
800
500
450
425
toilet grab rail
400 1635 665
2035
600 90 2700
AS1428.1 Circulation Space in Accessible Sanitary Facilities
Proposed Typical Unisex Amenities Layout
1 1 : 50
hot mezzanene floor mezzanene floor
Level 3 water
above bathroom Level
above3
bathroom
system
2600 2600
20 400
splashback
m/w
drawers drawers
storage
c'brd
800
fridge sink
920
c,brd
100
400 490 500 600 500 600
2490
Kitchentte Elevation 1 Kitchenette Section 1
E1 1 : 50 S1 1 : 50
Concept
Do not scale off this drawing. DRAWING REVISIONS Drawing Title: Project:
Check all dimensions on site. REV. DATE DESCRIPTION
Typical Bathroom & Kitchenette Proposed Industrial Units 16 & 17
Details 11 Bartlett St, Noosaville
All drawings are copyright and Orientation:
are owned and controlled by Client:
Collins Building Designs. All Robilliard Building & Scale: 1 : 50 @ A3 Drawing No:
Building works must comply
with current B.C.A and S.A.A. [email protected]
Mob: 0474 141 348
Design Date: 07.09.2020 Rev: A04_ A105
Page 6
Proposed Typical Front Facade
1 1 : 50
fixed glass window
1500mmH x 3800mmW
1500
1800
300
4200
fixed glass window roller door 4200mmH x 3600mmW
2000mmH x 2800W
2000
2400
400
glass entry door 2100mmH x
1000mmW with 300mmH
transome fixed panel
Typical Unit Front Facade
2 1 : 50
Concept
Do not scale off this drawing. DRAWING REVISIONS Drawing Title: Project:
Check all dimensions on site. REV. DATE DESCRIPTION
Typical Front Facade Details Proposed Industrial Units 16 & 17
11 Bartlett St, Noosaville
All drawings are copyright and Orientation:
are owned and controlled by Client:
Collins Building Designs. All Robilliard Building & Scale: 1 : 50 @ A3 Drawing No:
Building works must comply
with current B.C.A and S.A.A. [email protected]
Mob: 0474 141 348
Design Date: 07.09.2020 Rev: A04_ A106
Page 7
17
193m2
17
193m2
S1
A202 S1
A202
refer engineer for
post size & material
5090
90 5000
90
Office
5790
28.95m2
10090
90
Storage
4120
14 [email protected] mm 17m2
S1
S1
A202
A202
Shed 17 Proposed Floor Plan Shed 17 Proposed Mezzanene Floor Plan
1 1 : 100 2 1 : 100
Concept
Do not scale off this drawing. DRAWING REVISIONS Drawing Title: Project:
Check all dimensions on site. REV. DATE DESCRIPTION
Shed 17 Proposed Floor Plan Proposed Industrial Units 16 & 17
11 Bartlett St, Noosaville
All drawings are copyright and Orientation:
are owned and controlled by Client:
Collins Building Designs. All Robilliard Building & Scale: 1 : 100 @ A3 Drawing No:
Building works must comply
with current B.C.A and S.A.A. [email protected]
Mob: 0474 141 348
Design Date: 07.09.2020 Rev: A04_ A201
Page 8
2440
2221
Office Storage
2000
300
refer engineer for floor details
Bathroom
2300
Concept
Do not scale off this drawing. DRAWING REVISIONS Drawing Title: Project:
Check all dimensions on site. REV. DATE DESCRIPTION
Shed 17 Proposed Mezzanene Proposed Industrial Units 16 & 17
Section 11 Bartlett St, Noosaville
All drawings are copyright and Orientation:
are owned and controlled by Client:
Collins Building Designs. All Robilliard Building & Scale: 1 : 50 @ A3 Drawing No:
Building works must comply
with current B.C.A and S.A.A. [email protected]
Mob: 0474 141 348
Design Date: 07.09.2020 Rev: A04_ A202
Used in these records
Atachment A - proposal plans unit 17.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.7 MB (small file)
- File type
No other editions are linked here.