Original source · versioned page text
RFI - P0478-26-001_45_Maple_Street_Cooroy_SWMP
Original PDF page 19, section 1. The text section number identifies this passage in the reader.
5 Stormwater Quality 5.1 Introduction A stormwater quality assessment has been undertaken for the proposed development in accordance with the Urban Stormwater Quality Planning Guidelines (2010) and the Water by Design framework. The objective of this assessment is to demonstrate compliance with pollutant load reduction targets through the integration of an engineered treatment solution within the stormwater detention infrastructure. Rather than a conventional bioretention system, the proposed development will adopt a proprietary cartridge- based treatment device, such as the Atlan Filter or a similar approved product, housed within the proposed on- site detention (OSD) tank. This approach provides a compact and highly efficient solution to stormwater pollutant removal, suited to constrained development footprints and high-performance treatment requirements. 5.2 Proposed Treatment System The proposed stormwater quality solution involves the integration of a cartridge-based filtration system (e.g. Atlan Filter or similar proprietary system) within the base of the OSD tank. The filter unit will be positioned to intercept and treat stormwater prior to discharge to the lawful point. The filter unit provides multiple treatment stages including sedimentation, filtration, and nutrient removal within a self-contained cartridge unit, and is designed for high-flow bypass scenarios. The final configuration, cartridge sizing, and number of filter units will be refined during the Operational Works design phase in consultation with Atlan or an equivalent proprietary system supplier. 5.3 Expected Pollutant Reduction Performance Based on verified performance data from the Atlan Filter system (refer to https://atlanstormwater.com/au/atlan- filter), the treatment device has been demonstrated to achieve the following pollutant load reductions under typical urban runoff conditions: Table 5-1 Pollutant Reduction Targets Parameter Expected Reduction (%) Total Suspended Solids (TSS) ≥ 90% Total Phosphorus (TP) ≥ 65% Total Nitrogen (TN) ≥ 45% Gross Pollutants ≥ 99% These results align with or exceed the Water by Design pollutant reduction targets for Southeast Queensland. 45 MAPLE STREET, COOROY 24 June 2026 P a g e | 16 Stormwater Management Plan Client Reference: P0478-26-001 Prepared for Myall Rise PTY LTD
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original (RFI - P0478-26-001_45_Maple_Street_Cooroy_SWMP.pdf)
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.