Council archive · source document
09/1508 - Operational Works - Landscaping. Stormwater, S&E Control, Carparking & Acess, Frontage Works [As Published] · 142009.1508
~- J6 36.1 J6.2 J6.3 J6.4 36.5 56.6 37.2 O38 ASSESSMENT NO: 2009/ 0919 Artificial Lighting and Power Application of Part The Deemed-to-satisfy Provisions of this Part do not apply within a sole-occupancy unit of a Class 2 building or a Class 4 part of a building. Interior artificial lighting Interior artificial lighting must be installed as indicated in the attached report, and clarification may need to be certified by a Competent Person accepted by the Certifier. Interior artificial lighting and power control Interior artificial lighting and power control must be installed as indicated in the attached report, and clarification may need to be certified by a Competent Person accepted by the Certifier. Interior decorative and display lighting Interior decorative and display lighting must be installed as indicated in the attached report. Artificial Lighting Around the Perimeter of a Building Artificial lighting around the perimeter of a building must be installed as indicated in the attached report, and clarification may need to be certified by a Competent Person accepted by the Certifier. Boiling water and chilled water storage units A boiling water or chilled water storage unit is not indicated, however if installed will need to comply with the attached Report. Hot water supply A hot water supply system for food preparation and sanitary purposes, other than a solar hot water system in climate zones 1, 2 and 3, must be designed and installed in accordance with Section 8 of AS/NZS 3500.4. Access of Maintenance J8.1 Application of Part The Deemed-to-satisfy Provisions of this Part do not apply within a sole-occupancy unit of a Class 2 building or a Class 4 part of a building. 38.2 Access must be provided to all plant, equipment and components that require maintenance in accordance with Part 12 below:- Components of services must be maintained to ensure that they perform to a standard not less than they were originally required to achieve, including- (a) adjustable or motorised shading devices; and (b) time switches and motion detectors; and (c) room temperature thermostats; and (d) plant thermostats such as on boilers or refrigeration units; and (e) outside air dampers; and (f) reflectors, lenses and diffusers of light fittings; and ‘ (g) heat transfer equinment. 4 Lillypilly Court, Page No. 4 Phone: (07) 5493 2981 KAWANA FOREST.....4551. Fax: (07) 5493 3867
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
09/1508 - Operational Works - Landscaping. Stormwater, S&E Control, Carparking & Acess, Frontage Works [As Published]Related documentApplication case desk ↗
About this file
- File size
- 4.9 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.