J6

36.1

J6.2

J6.3

J6.4

36.5

56.6

37.2

O38

ASSESSMENT NO: 2009/ 0919
Artificial Lighting and Power

Application of Part
The Deemed-to-satisfy Provisions of this Part do not apply within a sole-occupancy unit of
a Class 2 building or a Class 4 part of a building.

Interior artificial lighting
Interior artificial lighting must be installed as indicated in the attached report, and
clarification may need to be certified by a Competent Person accepted by the Certifier.

Interior artificial lighting and power control

Interior artificial lighting and power control must be installed as indicated in the attached
report, and clarification may need to be certified by a Competent Person accepted by the
Certifier.

Interior decorative and display lighting
Interior decorative and display lighting must be installed as indicated in the attached
report.

Artificial Lighting Around the Perimeter of a Building

Artificial lighting around the perimeter of a building must be installed as indicated in the
attached report, and clarification may need to be certified by a Competent Person accepted
by the Certifier.

Boiling water and chilled water storage units
A boiling water or chilled water storage unit is not indicated, however if installed will need
to comply with the attached Report.

Hot water supply

A hot water supply system for food preparation and sanitary purposes, other than a solar
hot water system in climate zones 1, 2 and 3, must be designed and installed in accordance
with Section 8 of AS/NZS 3500.4.

Access of Maintenance

J8.1 Application of Part
The Deemed-to-satisfy Provisions of this Part do not apply within a sole-occupancy unit of
a Class 2 building or a Class 4 part of a building.
38.2 Access must be provided to all plant, equipment and components that require maintenance
in accordance with Part 12 below:-
Components of services must be maintained to ensure that they perform to a standard not
less than they were originally required to achieve, including-
(a) adjustable or motorised shading devices; and
(b) time switches and motion detectors; and
(c) room temperature thermostats; and
(d) plant thermostats such as on boilers or refrigeration units; and
(e) outside air dampers; and
(f) reflectors, lenses and diffusers of light fittings; and ‘
(g) heat transfer equinment.
4 Lillypilly Court, Page No. 4 Phone: (07) 5493 2981

KAWANA FOREST.....4551. Fax: (07) 5493 3867

Used in these records

About this file

File size
4.9 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

09_1508 - Operational Works - Landscaping. Stormwater, S&E Control, Carparking & Acess, Frontage Works [As Published].pdf · 4.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.