                                                                                                                         43° 00' 32" 31.89 m                                                                   A300                            PROPERTY BOUNDARY
    EG EDGE GUTTER
                                                                                                                                               11145                                                    3240
    RSb ROOF SHEETING ZINCALUME
                                                                                                                                                                                                                N




                                                                                                                                                                                                                             2000
                                                                                                                                                       5790
                                                             6000
                                                                                                                                                                                                                                               SEWER EXCLUSION

   NOTES:
                                                                                                                                                                                                                                                                                                   a
   All work to conform with Part MP 4.2 of the Queensland
   Development Code (QDC) (Water Saving Targets).




                                                                                                                                                                                                                                                                                                 108
   Roof stormwater is to discharge to local government




                                                                                                                                                                                                                                                                                                  °0
   requirements and approval. Downpipes not                                                                                                                   3°                                                                                                                   0




                                                                                                                                                                                                                                                                                                   0' 2
                                                                                   EG
   connected to rainwater tank/s to discharge to                                                                                                                                                                                                                              600         k
                                                                                                                                                                                                                                                                                      bac




                                                                                                                                                                                                                                                                                                        5"
   interallotment drainage system/ to nominated
                                                                                                                                                                                                                                                                                r set
                                                                                                                                                                                                                                                                            rea




                                                                                                                                                                                                                                                                                                         22.
   discharge points via bubbler system/ to discharge to                                                                  RSb




                                                                                                                                                                                                                                                                                                            18
   street channel system.




                                                                                                                                                                                                                                                                                                             m
   Based on assumed 5 minute rainfall intensity -                                                                                                      Louvers to Skylights
   240mm/h                                                                                                                                             Angled to Winter Sun
   20 years recurrence interval.                  A301       W
                                                                                                                                                                        SKYLIGHT
   Gutters & downpipes shall be in accordance with                                                                                                                                                                                                                                                 b




                                                                                                                                                                                              814
   AS/NZS3500.5 domestic & Part 3.5.2, Vol 2 of the NCC.

   All downpipes to be 90mm/100mm U-PVC.                                                                                                                                                                                                                                                                E        A301
   All gutters to be 200mm Stratco Edge Gutters
                                                                                                                               EG
                                                                                                 EG                                                           FIRE SEPARATION WALL 60/60/60

   Falls to be in accordance with clause 3.5.2.4, Vol 2 of
   the NCC.                                                                                                         8°                                                                                                                                                                              c
   •    Effective roof catchment area 201.4m²                                                                                                                           SKYLIGHT
   •    Number of downpipes 6
   •    Roof catchment per downpipe 39.25m²
   •    Downpipes must not serve more than 12m of
        gutter length for each downpipe                                                                                                                                                                                                                                                            d
   •    Total rainfall intensity 235.5m² X 240mm/39.25=
        1440.0L/min
   •    Stormwater pipes - 100 dia. Laid at 1 in 100
        minimum grade.

                                                                                                                                    RSb
                                                                                                                                                                    3°
   Downpipes are to be located where they will not
   create a hazard to building users nor impede window
   & door openings and the like. They are to be installed
   as close as practicable to the supporting structure
   while maintaining termite inspection clearances of
   25mm. Downpipes are to be protected from potential
                                     313° 00' 00" 20.10 m




   mechanical damage, be installed no less than 100mm
   from electrical cables & gas pipes & no less than 50mm
                                                                                                                                                                                                                                                                                                   e
                                                                    500




   from other services (AS3500.3.2 S4.11)                                                   EG
                                                                    1500




                                                                                                                                                                                 1500
   Downpipes are to service 12m maximum
   gutter length & be within 1.2m from each
   valley unless overflow is provided for                                                                                                                                                               6                                                              223° 00' 43" 41.26 m
   (NCC Vol2 P3.5.2.5)                                                                                                                                         S

                                                                                                                                                                                                                                                                        PROPERTY BOUNDARY
                                                                           1   2        3             B                                        4           A300                                     5



                                      1 ROOF
                                        1 : 100
                                                LEVEL
                                                                                                                                                                                                                      CD4c
                                                                               REV                    DESCRIPTION                   DATE
                             NEW BUILD                                                                                                                                                                                ROOF LEVEL                                             JOB:             2401
                             For:
                                                                                                                                                                                                                                                                             DATE:            06.03.25
JOSH WALKER STUDIO                  Clinton Dow
                                                                                                                                                                                                                                                                             DRAWN:           J.Walker
joshwalker.com.au
0409.921.601
                             Nebula Duplex                                                                                                                                                                            A106
QBCC #15018637               18 Nebula St Sunshine Beach QLD                                                                                                                                                          COPYRIGHT BY WALKSTUDIO. THIS DRAWING OR PARTS
                                                                                                                                                                                                                      THEREOF MAY NOT BE REPRODUCED FOR ANY
                                                                                                                                                                                                                                                                            SCALE(A3):        1 : 100
                                                                                                                                                                                                                      PURPOSE WITHOUT THE CONSENT OF WALKSTUDIO.
Log in to download the original file

DA ISSUE CD4c 18 NEBULA DUPLEX.pdf · 6.5 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.