Council archive · source document
MCU15/0087 Approved Plans
Plans and drawings: the text below has words only, no drawings.
DIMENSION FROM -
90 30 90 90 90 CORNER BOUNDARY
90 2965 610 760 2920 90 1900 410 3315 TO FACE OF WALL NOOSA COUNCIL
APPROVED PLAN
2
3660 MCU15/0087 21 SEP 2015
A300
1995
RETAINING WALL SETBACK
1880 NO. DESCRIPTION DATE
690
90 1200 90
90 1200 90
1 COUNCIL SUBMISSION 21.05.15
- Boundary Relaxation
1220
DP DP
90
2 Open space conv. zone 11.06.15
700
COURTYARD
RETAINING WALL
JOINERY FP DP
90
SHELVING
tv
ENS.
3620
2800
STUDY Sound proof CH 2850
CH 2700
wall type
LIVING
5100
RI.
CH 2850
90
MASTER KING
1800H SCREEN
7500
CH 2850
90
GALLERY
1580
KB
DRYING COURT
90
BBQ DISPLAY
90
4200
Airlock
1820
.
R POWDER
VE CH 2850 W.I.R PROJECT ADDRESS:
O DRW CH 2800 865
LOGGIA ID
90
VO 1 Natasha Ave,
17100
CH 2850 1665 SETBACK
STORAGE DP
L.C HWS SB Noosa Heads Qld
200
1200 LOCKABLE
S. AUSTRALIA 4567
R
90
5000
VE
2475
1800H SCREEN
KITCHEN
FO
VOID OVER
20080
motorised
O
UTILITY step
RO
roller door
S CH 2850
CLIENT:
90
1600 LIFT CAR MOTOR Mr. J.B. Prescott OA
WINE
UNDER STAIR PO Box 16127
GARAGE Collins St. West, Vic 8007
CH 2850
90
CONC.
800
1400 PANTRY FRIDGE DESIGNER:
1400
7800
Annette Warner Pty Ltd
7500
GALLERY 1 Building Design Consultants
DISPLAY
A300 PO Box 1234
Noosa Heads Qld 4567 Australia
2625
ENTRY 26450 ph: +61 7 5447 4893
5000
1750
DINING CH 2850 step
CH 2850
26500 DRAFTING:
Deck
.
1500
LOBBY
1000
CH 2850
PO BOX 687,
NOOSA HEADS, QLD 4562
200
200
EMAIL: [email protected]
QBCC: 1285397
1200
JOB NO.
1800H SCREEN
LIFT 305
1810
1890
SETBACK
SW.POOL SETBACK KL15B06
3000
3000
3000
3000
2990
1
DRIVEWAY
A400
SCREEN
DRAWING TITLE
1200
1000
785
gate PROPOSED GROUND
FLOOR PLAN
2200 90 3000 90 1200 90 1470 90 2930 35 1400 200 7000 200
DRAWING NUMBER
5500 DIMENSION FROM
19795 295 A101
N
CORNER
BOUNDARY TO
FACE OF WALL Scale as shown @ A3
NOTES
1. GENERALLY THE BUILDER SHALL COMPLY WITH THE REQUIREMENTS 3. FIGURE DIMENSIONS ONLY ARE TO BE USED, WITH NO DIRECT SCALING FROM 5. BUILDING METHODS ARE SUGGESTED ONLY. THE CONTRACTOR REMAINS Rev Date : Rev No :
OF THE LOCAL AUTHORITIES AND ADHERE TO THE PROVISIONS OF THE
BUILDING CODE OF AUSTRALIA
THE DRAWINGS ALLOWED. RESPONSIBLE FOR ALL METHODS AND MATERIALS CONFORMING TO THE
APPROPRIATE CODES AND STANDARDS
CONCEPT DESIGN 31/08/15 3
4. ALL LEVELS AND DIMENSIONS ARE TO BE CHECKED
2. ALL DIMENSIONS SHOWN ON THE DRAWINGS ARE TO BE CHECKED 6. ALL SCHEDULES ARE PROVIDED TO ASSIST WITH ESTIMATION ONLY.
AND VERIFIED ON SITE BEFORE BUILDING WORK COMMENCES
IT IS THE RESPOSIBILITY OF THE BUILDER / CONTRACTOR
ON SITE BEFORE WORK COMMENCES, ANY QUIERIES ARE TO BE DIRECTED
TO CONFIRM ALL QUANTITIES
NOT FOR CONSTRUCTION Drawn by : Checked by :
TO THE DESIGN AUTHORITY.
AXK AW
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
MCU15/0087 Approved PlansRelated documentApplication case desk ↗
About this file
- File size
- 2.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.