Council archive · source document
Amended Plans (Rec 11.6.25) 2502 DA03 10062025 · MCU25/0054
Plans and drawings: the text below has words only, no drawings.
Very large file (17.3 MB): may take a few minutes to open.
♻ play your part - print on recycled paper
5m 4 3 2 1
Knotwood Hinoki 150 x 25mm battens @150mm cts. to provide Concrete block wall to be in accordance with structural engineers
privacy screening. design and detail. Provide acrylic render system with fine sand finish
and painted with selected colour in accordance with final colour
selections to exposed wall surfaces.
HDG steel spiral stairs to be in accordance with manufacturers
design and detail. Stairs to be in accordance with ABCB Housing
Provisions Standard 2022 : 11.2 Stairs and handrail to have selected
powder coated finish with 75 x 25mm Knotwood Hinoki hit & miss
batten balustrade screen to spiral staircase. Suspended concrete green roof to be in accordance with structural
engineers design and detail. Planter to have 40mm upvc drainage
outlets and Soprema Landscape waterproofing system with premium
soil fill and plants to landscapers specifications.
35.707m, 49° 0' 0.00"
wall setback
wall setback
wall setback
2,500
2,500
2,500
Knotwood screen Knotwood screen
Planter Planter
7,217
lift lift Wall setback
8,501 Lounge Lounge
Tile Tile
wall setback
6,151
stair setback
891100
7789 99887766
10
10
566 11
4
11
12
12
13
11
11
12
12
13 54
321 15 13
14
14 13
14
15 123
14
up up
4,867
U1 U2
up up
15.490m, 139° 0' 0.00"
Stair setback
Dining Dining
Planter
Planter
15.490m, 139° 0' 0.00"
Tile Tile
Pdr 1 Pdr 1
Tile Tile
Terrace Terrace
Tile Tile
wc
wc
b b
dw dw
s s
dw dw
s s 5,417
10,000 Planter setback
Scullery Scullery
wall setback Kitchen Tile Tile Kitchen
Tile Tile
bbq ct ct bbq
2x Planter Planter 2x
rh ref ref rh
Planter Planter
Knotwood screen
Knotwood screen Knotwood screen
wall setback
4,200
wall setback
wall setback
3,100
3,100
35.707m, 49° 0' 0.00"
Knotwood Hinoki 150 x 25mmbattens @150mm cts. to provide
privacy screening. Knotwood Hinoki 100 x 50mm @150mm cts. to provide balustrade in
accordance with ABCB Housing Provisions Standard 2022 : 11.3.
Balustrade to be a min. 1000mm high above finished floor level.
Concrete block wall to be in accordance with structural engineers
design and detail. Provide acrylic render system with fine sand finish
and painted with selected colour in accordance with final colour Suspended concrete green roof to be in accordance with structural
selections to exposed wall surfaces. engineers design and detail. Planter to have 40mm upvc drainage
outlets and Soprema Landscape waterproofing system with premium
soil fill and plants to landscapers specifications.
Conceptual plan - First floor
1:100
/Users/benthornton/Documents/Cadfiles/2502 - Palazzesi - 20 William/
Archicad/09062025/2502.pln
sbt designs pty ltd t/a
Skale Building Design project Duplex Residence lot no. 3 DA03 Development application issue 10/6/2025
project number
Mobile: 0412 025 657
for Ross Palazzesi plan no. RP 63813 DA02 Development application issue 25/3/2025
2502
skale skale.com.au
DA01 Development application issue 4/3/2025
20 William Street drawn BT
CD07 Conceptual design issue 26/2/2025
drawing number
[email protected]
building design A.C.N. 123 976 296 QBCC: 1143 609 at Noosaville scale (A3) 1:100 Rev Details Date 07 DA03 © Skale Building Design
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
AMENDED PLANS (REC 11.6.25) 2502 DA03 10062025.pdfRelated documentApplication case desk ↗
About this file
- File size
- 17.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.