08/1546 - Additional information as requested - Dwelling & retaining Walls [As Published] · 132008.1546
Steel Posts
‘Steel Column
Pad Footing Depth
Refer Page 1
150 (Min)
a
k——|
450 Diameter
Steel Posts
4e N12 Bars
welded to plato
RS Li 250
Pad Footing Depth ae ah 20 er
Rafer Page 1
L
450 Diameter
Design Company
STA CONSULTING ENGINEERS
Suite 1, 848 Boundary Rd, Richlands, Qid, 4077
ACN 129 441890 Fax (07) 33759299 Ph.3363 8181
SOKA Builder *
Bob & Sheryl Hedges
s
Swot N eens PO Box 6354, St Lucia Qld 4067
Project Job No, 9141
Technical Notes
Earth Works Specifications
Batter Angles for Embankments:-
{tis the budders responsibility to ensure that the site works do not undermine or place additional surcharge on any existing structures.
if this can not be achieved STA Consulting Engineers must be contacted prior to any site works being undertaken.
Batter angies must comply with toca! goverment requirements and are to conform as follows {Figure 1).
Figure 1.
Cut Embankment
Lv Fill, H tess than 2.Gm
Material Type Clay
Soft Sols
{Refer Bore Logs} Firm Clay | Soft Clay
Embankment Slopes | Compacted Fill : : 1:2 | Norsunabe
(Height Length)
Cutting : : : 1st 2:3
Note: Retaining walls or other forms of soil retaining methods must be adopted where the slope ratio is greater than that
indicated in the table above
Fill Material and Compaction:-
‘Organic material, highly reactive clays and lange racks ara not suitable for use as fill. The fill is to be spread in 1S0mm layers and extensively
track rolled with a drott. All earthworks to be carried out in accortiance with the full requzements of AS3798-1990, Guidelines tor Earthworks for
Commercial and Residential Developments.
Drainage:-
‘The external finished surface surrounding the dwelling must be drained to move surface water away from the buikling and graded to give a stope
of not less than SOmm over the first 1m away from the buikiing.
Reinforcement Specifications
‘Steel wire reinforcing fabric and bars to conform with AS 1304 - Hard Drawn Stee! Wire Reinforcing
Fabric for Concrete} and AS 1302 - Steel Reinforceing Bars For Concrete.
Lap Lengths
Trench Mesh - 500mm in a straight fine, or to the far face at “T” and "L" intersections
Steel Gars - “N" Bars - 35 times the bar diameter.
Corner Bars - sequired at all “T* and “L” intersections. Refer to the design drawings for
the appropriate construction details.
‘Slab Fabric - One full panel of the fabric, so as the two outer-most transverse wires of each sheet
are overlapped. As shown on the below detail (Figure 3).
_2daillonal width, For example a 400mm wide
200 x 100 Eage Square fooling requtan 4 bar tench mash SOG wide,
Concrete Specifications
The concrete must have a strength at 28 days of no! less than 20MP=a unless otherwise specified an tha foundation cross section, a 20mm nominal
aggregate size and have a nominal 60mm slump. Water must not be added to the mix to increase the slump to a value in excess of that specifiad,
Concrete must be placed and compactad/vibrated with good building practice. in hot and windy conditians concrete must be cured dy covering with
plastic sheeting, spraying with e liquid membrane curing campound ef ponding water on the top surface. The concrete must be manufactured to
comaly with AS3600-2001 - Concrete Structures.
Builders Client
NIA
Client Order Number: N/A
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
08/1546 - Additional information as requested - Dwelling & retaining Walls [As Published]Related documentApplication case desk ↗
About this file
- File size
- 2.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.