Foundation Design Report

Date: 24th June, 2009
Project Job Number: 91485 Amended
Site Address : Lot 23 Whale Drive, Sunshine Beach
Local Authority : Sunshine Coast Regional
Site Classification
(at time of Soil Testy: l@88P
The site classification Is based upon drainage and tree issues being addressed by the installation of adequate on site drainage
measures and the installation of root barriers as outlined in Section 2.0 of the STA Alliance Reference Guides.
The "P* classification is due to tow bearing capacities encountered in the soil profile. This report does not cover slope stability. If this is required, i is
commended that an independent test be carted aut by a qualified Geotechnical Engineer specialising in this area.
Site Details P Building Design Detal Proposed Site Preparation Details
{at time of soittest) (supplied by our client) (stipulated by our client)
Vegetation: Scrub Multi Storey
Slope: Very Steep Face Brick, Block and Cladding Cut / Fill
Drainage: Good Concrete and Timber Floor
Site preparation
The construction pad is to be cleared of vegetation and loose material. The pad is to be prepared in accordance with the propased site preparation details

a8 indicated to Soiltest Australia Engineering Services Pty Ltd (Le. Cut/fil, total cut etc.) If any trees are removed from the buikting pad area, the voids
created by their removal, must be excavated, backfilled and compacted with suitable material.

| Founding Materia!
; Edge Beam and Slab : Natural Medium Dense Silty Sand
fl Pad Footings for Posts & Point Loads : Natural Medium Dense Silty Sand

\ Minimum Depth of Pad Footings :
‘Where the depth to suitable founding material is significant, excavated or drilled piers can be adopted, Where the length of drilled footing piers exceeds.
1500mm, they are to be reinforced with 4/N12 bars tied to an R6 spiral @ 150mm pitch or equivalent & fied into the Edge Beam Footing cage.
Ahemativety an equivalent pre-fabricated steel cage may be adopted. Footing depth may ba reduced where refusal on shallow rock is encountered,
providing bracing and tie-down requirements are not adversely affected. When the required bracing and tie-down requirements are not attained rock
anchors must be utilised, Note; Pad faoting depth and/or diameter is also subject to bracing and tie-cown requirements,

———Shatlow Rock, Boulders and Rock Qutcrops

The depth of the edge beam may be reduced where refusal on shallow rock, on a rock boulder or partially over a small rock outcrop is encountered.
‘Where this depth is less than 400mm, top steel, comer bars and starter bars may be deleted. Note; Before the beam depth becomes less than 400mm,
top steel is to be lapped 500mm with the bottom steel. ft is also required that a minimum edge beam depth of 200mm must be maintained at all times. It
is also recommended that the wafls are articulated at the ster! and end of the rock outcrop.

Masonry Articulation
All masonry walls, except retaining wafls, require full height (footings to eaves) asticutation @ 5 metre spacings (maximum) regardiess of comers, Refer
Technical Note 61 produced by the Cement and Concrete Association for details,

 

 

 

ortification of Soils and Desi te} - Obfigations iider and Home Owner/Occupier
The performance of the footings and stab or both is largely depended upon # responsible approach by the builder and owner/occupier towards vegetation
and site drainage.
THE DESIGN DOCUMENTATION REFERENCE GUIDE VERSION 6002 2.1.
4. Is part of this Foundation Design Report and this Foundation Design Report cannot be relied on without it;
2. Must be read and understood by the butder,
3. Contains requirements and recommendations, and ail requirements and recommendations must be complied with by the builder;
THE HOME OWNER’S REFERENCE GUIDE VERSION 6002 1.1.
1. {8 part of this Foundation Design Report for the use af the homeownerfoccupler;
2. Must be read and understand whera appropriate by the homeawnerfoccupier,
3. Contains requirements end recommendations, and all requirements and recommendations must be complied with by the homeawner/occupier,

‘Where there is ANY FAILURE of the builder or homeowner/occupier to comply with the above obligations then the RESPONSIBILITY for ANY FAILURE
fests with the builder or homeowner/occupler.

Gee
fan

a
B,Sc., (Civil) RPEQ #4425

Design Company SIA Builder
STA CONSULTING ENGINEERS 4
Suite 1, 848 Boundary Rd, Richlands, Qld, 4077 CONSULTING Bob & Sheryl Hedges

ACN 129 441890 Fax (07) 33759299 Ph.3363 8181 ENGINEERS PO Box 6354, St Lucia Qk 4067

TEST SITE@1 TEST SITE@-2

TYSAND
(Grey)
Motst & Loose

(Grey)

Organics Encountered (Tree Roots)
(Grey)
Moist & Loose to Medium Dense

ENO (Hand Auger)

 

 

Dynamic Cone Penetrometer
Allowable Bearing Capacity (kPa)
Pocket Penetrometer Strength (kPa)
Unable to Penetrate

Slope Direction

Test Methods: AS1289 3.1.2 (liquid Fimit), 3.4,1(near shrinkage), 7.1. 1{shrink-swell)

Builders Client
NIA
Client Order Number: N/A

 

Used in these records

About this file

File size
2.0 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

08_1546 - Additional information as requested - Dwelling & retaining Walls [As Published].pdf · 2.0 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.