Council archive · source document
planning report 7 Woodland · MCU23/0008
5.1.6 Sustainable Building Design Code
An assessment against the Performance Outcomes (PO8) of the Sustainable Building Design
Code is provided below
Performance Outcome Comment
orientates buildings and All tenancies have substantial openings for cross flow
windows to make the most of ventilation. In particular Caretakers ensures natural
prevailing winds, natural ventilation occurs in the bedroom and living spaces with
ventilation, and cross breezes; direct access to a balcony.
maximises shade to east and The main frontage face west and strategically placed
west walls; battening provides shading to the building spaces. The upper
floor raised planter provides natural cooling. Awnings and
eaves also provide shading to the walls.
contains an open and permeable Permeable built form includes direct access to a balcony in
built form that connects indoor the Caretakers form the living and bedroom spaces. The
and outdoor spaces in an commercial tenancies have extensive shaded glazing with
integrated design; some areas overlooking raised planters to provide an
integrated design.
retains existing vegetation and There is no vegetation onsite (except one small shrub). More
natural shading where possible; than 2 times the required planning scheme quantity of soft
landscaping is proposed, all to the perimeter of the site
providing good shading.
incorporates The architecturally designed building unfortunately faces
passive building design to west by location but the architect has provided an excellent
reduce the need for auxiliary sustainable response to offset this, by offering battening and
heating and cooling; strategically placed openings and masonry walls to help with
thermal comfort.
uses low toxic internal and A mix of low toxic internal and external materials are
external building materials; incorporated for the construction which will ensure long
lasting design that does not require regular maintenance.
uses natural light rather than Natural light is provided through the lobby and external
artificial light, and may include glazing.
skylights, atriums and light wells;
provides a minimum floor to The design proposes a 3m floor to ceiling distance.
ceiling height of 2.7 metres; and
enables efficient operation and The design allows for the uses to operate without the need
use of the building. for mechanical ventilation by providing battening and
overhangs to allow the building to breathe and the
commercial and accommodation use.
5.1.7 Works Codes.
The proposal can comply with all relevant engineering code which is demonstrated by the following
reports provided as part of the application package-
Concept Stormwater Management Plan, prepared by SCG Consulting Engineers;
Vehicle Turning Paths, prepared by SCG Consulting Engineers
Traffic Impact Assessment prepared by Fernway Engineering
Page 16 of 17
See the original
The page text is free to read. Viewing or downloading an original file needs an account.