                                                           Catchment (E) Rational Method Analysis

                                                           Site Location:
                                                           Tewantin
Q = CIA/360                                                IFD data from BOM
Where:                                                     DURATION1 Year        2 years      5 years    10 years 20 years 50 years 100 years
Q = Flow rate (m3/s)                                       5Mins          129.00       164.00    202.00     223.00   253.00    291.00    321.00
C = Coefficient of discharge                               6Mins          121.00       154.00    189.00     210.00   238.00    275.00    302.00
I = average rainfall intensity (mm/hr)                     10Mins          99.30       126.00    156.00     173.00   196.00    227.00    250.00
A = area of catchment (ha)                                 20Mins          73.10        92.90    115.00     128.00   145.00    168.00    185.00
                                                           30Mins          59.70        76.00     94.20     105.00   119.00    138.00    152.00
I = Requires time of concentration (Tc)                    1Hr             40.40        51.60     64.70      72.30    82.70     96.30    107.00
Tc calculated by Friends Equation                          2Hrs            25.90        33.40     42.80      48.40    55.90     65.90     73.50
                                                           3Hrs            19.60        25.50     33.20      37.90    44.10     52.50     58.90
Friends Equation: Tc = (107nL0.333)/S0.2                   6Hrs            12.20        16.00     21.50      25.00    29.50     35.60     40.40
Where:                                                     12Hrs            7.72        10.20     14.10      16.60    19.90     24.30     27.90
n = Hortons surface roughness factor                       24Hrs            5.09         6.78       9.51     11.30    13.60     16.70     19.30
L = overland sheet flow path length                        48Hrs            3.37         4.51       6.38      7.61     9.18     11.40     13.10
S = slope of surface (%)                                   72Hrs            2.54         3.41       4.88      5.86     7.10      8.83     10.20


            Existing Developed                                                     Existing      Developed
Tc (mins)         15.8       5                                       n                    0.045
                                                                     L                        62
Therefore intensities (I) using Tc are as follows:                   S                       2.5
                                                                     Tc = (mins)            15.8       5.0 **Standard inlet time adopted
   ARI      Existing Developed
    1            81.45  129.00
    2           103.52  164.00
    5           128.06  202.00
   10           142.00  223.00
   20           161.34  253.00
   50           186.66  291.00
   100          205.83  321.00

1 hour 10 year intensity (1I10)=
       72.30
1
  I10 used with Fraction impervious (Fi) to determine C10 then multiplied by Frequency factor (Fy)

            Existing Developed
Area (ha)       0.1532    0.06                **Note: C10 value derived for existing conditions as Intenisty, Area, and Flow were known values
Fi                    0     0.8
C10                 0.7   0.86                ARI          Frequency factor (Fy)
C1               0.560   0.688                         1         0.8
C2               0.595   0.731                         2        0.85
C5               0.665   0.817                         5        0.95
C10              0.700   0.860                        10           1
C20              0.735   0.903                        20        1.05
C50              0.805   0.989                        50        1.15
C100             0.840   1.000                       100         1.2


Flow rates can then be calculated by Q = CIA/360:
                  Q (m3/s)
ARI        Existing Developed               Roof 180m2               Post (Minus Roof)          % Change to Boundary
     1          0.019      0.015                0.005                      0.010                   -62.7%
     2          0.026      0.020                0.006                      0.014                   -62.6%
     5          0.036      0.028                0.009                      0.019                   -63.0%
    10          0.042      0.032                0.010                      0.022                   -63.4%
    20          0.050      0.038                0.010                      0.028                   -57.0%
    50          0.064      0.048                0.010                      0.038                   -51.0%
   100          0.074      0.054                0.010                      0.044                   -51.4%
Log in to download the original file

Amended Stormwater Plan.pdf · 2.8 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.