Council archive · source document
Att 2 - trade waste · MCU17/0020
Attached to the e-mail Development application - Aquaculture MCU17/0020.
ATTACHMENT 2 - TRADE WASTE PERMIT [OCR of page images] ATTACHMENT 2 - TRADE WASTE PERMIT Head Office: Grownd Floor, 33 King Street ‘Caboolture QLD 4510 a Mailing Address: Unitywater PO Box 953, Caboolture QLD 4510 Serving you today, 1300 G UNITY (1300 086 489) investing in tomorrow. www.unitywater.com ABN: 80 791 717 472 Unitywater Trade Waste Assessment Letter 3 March 2017 Josh McNally Grouper Industries Pty Ltd PO Box 1860 NOOSAVILLE QLD 4566 iesh@noosaecomarine,com.au Dear Josh RADE WASTE ASSESSMENT FOR THE PROPOSED AQUACULTURE FACILITY LOCATED AT 3 SANDERS STREET | refer to your plan recently submitted to Unitywater for assessment: No. 0104 This assessment constitutes Unitywater’s consent to accept the trade waste to sewer. The following is Unitywater's Trade Waste Section assessment of the submitted plan and supporting information. 1. Assessment: You are advised that Unitywater’s Trade Waste Department has approved the trade waste installation design, as per the above mentioned plan. Also, rade waste permit #15866 will be issued to the proposed facility when the criterion in section four (4) has been addressed. 2. Pre-Treatment Facility: It is noted that the drawing includes the following trade waste pre-treatment facility; * 10000 litre wastewater settling tank, 3. Unitywater’s Guidelines. You are advised that the wastewater settling tank to be installed on the abovernentioned property will generally meet Unitywater's guidelines for the pre-treatment of trade waste likely to discharge from the abovementioned aquaculture facility. 4. Issues to be addressed ‘You are advised that the following must be addressed @) Unitywater's trade waste section must be notified when the plumbing works have been completed b) Set the wastewater discharge pump pick up point 500mm off the base of the wastewater settling tank c) Install @ discharge flow meter capable of continuous measuring ¢) Install @ conductivity meter on the discharge line ) Provide a sampling point before discharge to sewer Quality and Quantity f) TDS salt concentration must be less than 15000 mg 9) Wastewater discharge not to exceed 5000 litres/day or 3.5 litres per minute 5. Not included in this Assessment Please note this assessment does not; a) Approve other connections to Unitywater water supply or sewage systems; b) Pre-empt approval or compliance with Council's Development approval conditions; c) Constitute or imply compliance with the Plumbing and Drainage Act 2002; ¢) Constitute or imply approval of the plumbing or drainage fixtures, items, apparatuses or associated pipe work; ) Constitute or imply approval or compliance with any State or Federal legislation or Local Laws’. f) Constitute or imply approval for the structural integrity of the proposed pre-treatment device. Should you require further assistance, please contact Unitywater’s Trade Waste Officer, Mr Chris Cull on 5352 9424 or email {radewastewunitywater.com Yous nN (A ‘ Neale Head TRADE WASTE UNIT LEADER UNITYWATER Page 1 of f F Unitywater has certification to ISO 8001 Quality Management and = ISO 14001 Environmental Management, Unitywater is @ statutory authority that services the Moreton Bay, Sunshine Coast and Noosa local authority areas on behalf of its citizens. It is governed by an independent board. Councits do not have control or direction over day to day operations.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Att 2 - trade waste.pdfRelated documentApplication case desk ↗
About this file
- File size
- 241 KB (small file)
- File type
No other editions are linked here.