Original source · versioned page text
Reference Document - MCU25 0101 (As Published)
Project No. PG-13872 Page | 9 August 2025 Ref: PG-13872, 2025-08-14, GR VER 1 Stephen & Jane Struss – Geotechnical Investigation - Proposed Residence, 28 Kingfisher Drive, Peregian Beach iii. Excavate the site to the design basement level and test the base of the excavation to determine the extent of over-excavation required. iv. Following determination of the required extent of over-excavation, excavate the site to the required level and compact the exposed sands using a large (300kg plus) vibrating plate compactor or a small smooth drum roller. It should be noted that the silty sands encountered at some test locations could be difficult to compact and manage, if not appropriately dewatered. It may be necessary to remove the silty sands and replace them with clean sands from higher in the excavation profile. v. Replace the over-excavation with “clean” sand and compact in layers to the design founding level. The founding soils should be compacted to a minimum Density Index of 75% (in accordance with AS 1289 5.6.1). Foundation Design Parameters For footings founded between 2m and 4m below the ground level, an allowable bearing capacity of 225kPa could be adopted, following confirmation that a minimum Density Index of 75% is present for a minimum depth of 1m below the footings. If the exposed sands are disturbed or loosened during the excavation operation, they should be recompacted. Consideration should be given to placing a 50mm thick (minimum) concrete binding layer across the footings, immediately following excavation. Settlement Potential Settlements from underlying improved sands and natural soils beneath a pad footing of 2.5m width (i.e. maximum column load of 1500kN) at a nominal founding depth of 2m to 4m below existing ground level at a design bearing pressure of 225kPa have been calculated to be in the order of 15mm with anticipated differential settlements of between 25% and 50% of the calculated total settlement for pad footings founded at a similar depth. The settlement will occur as “immediate” settlement as the building loads are applied. Hydrostatic Uplift Forces For a fully tanked basement, hydrostatic uplift forces should be considered in the design. It is recommended hydrostatic uplift forces in groundwater levels to at least RL1.5 to 2.0 be taken into consideration on this site and checked for the Q100 flood condition.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.