10/0338 - Op works - Jetty [As Published] · 142010.338
76 x 38 HWO
1/76 x No14 TYPE 17
STAINLESS STEEL
SCREWS @ 450 CRS
PLES:
@ 200 H8 MARINE HWD POLES
NOTE THAT ALL POLES TO COMPLY
WATH AS 2180 - PILING CODE
SECTION A.
= Ne
JETTY USE:
SINGLE USER, PRIVATE
NO VEHICULAR ACCESS
WALKWAY DECK VERTICAL
DESIGN LIVE LOAD - 2.0 kPa
MAXIMUM MOORED VESSEL - 5m
BERTHING VELOCITY - 0.5 m/sec
180 x 75 HWO:
PLES:
© 200 HO MARINE HWD POLES
NOTE THAT ALL POLES TO COMPLY
WITH AS 2158 - PLING CODE
200 x 75 HWO
2688
8§ 160 x 76 HWO
180 x 75 HWD
Be TAILS ; \
NOTES:
1. UNLESS NOTED OTHERWISE ALL TIMBER SHALL BE
DURABILITY CLASS 1 OF APPROVED SPECIES AND HAVE
A STRESS GRADE OF F14 MIN.
2. UNLESS NOTED OTHERWISE ALL CONSTRUCTION SHALL
COMPLY WITH THE ENVIRONMENTAL PROTECTION AGENCYS'
OPERATIONAL POLICY - “BUILDING AND ENGINEERING
STANDARDS FOR TIDAL WORKS.
3. ALL STAINLESS STEEL BOLTS, RODS, ETC., SHALL BE
APPROVED MARINE GRADE 316. ALL OTHER STEELWORK
INCLUDING NUTS, BOLTS, WASHERS, SCREWS, NAILS, ETC.,
SHALL BE HOT DIPPED GALVANISED OR STAINLESS STEEL.
4. TOP OF PILES SHALL BE SEALED AND FULLY CAP FLASHED
OR RINGED.
5. DIMENSIONS AND LEVELS SHALL NOT BE SCALED FROM
THE DRAWINGS.
" 05/63-2