Skip to the record
Accept no substitutions.

Original source · versioned page text

SUPERSEDED - Compiled Approved Plans 51983 3225 15

of 86

Page text shows just the words. Original shows the document exactly as it was published.

Very large file: it may take a few minutes

The original of this document is very large (28.0 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Original PDF page 38, section 1. The text section number identifies this passage in the reader.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
           GENERAL SPECIFICATION                                                                                                                                     Construction Notes
                                                                                                                           Timber Frame: Framing to be built in accordance with AS 1684 Termite protected timbers shall be used on all framing
   ALL BUILDING WORK TO BE CARRIED OUT TO THE BUILDING CODE OF AUSTRALIA & THE BUILDING ACT 1975.                          Approved type flashing & sarking to be attached between cladding & frame along with slab & frame to prevent moisture getting to the frames
   BUILDER TO SUPPLY FOOTPATH PROTECTION & REQUIRED SIGNS TO COMPLY TO WORKPLACE HEALTH & SAFETY ACT.
   PRINCIPLE CONTRACTOR TO HAVE A SITE SPECIFIC WORKPLACE HEALTH & SAFETY MANAGEMENT PLAN TO COMPLY WITH                   All wet areas to be made waterproof or resistant to comply to AS 3740 & BCA 3.8.1
   GOVERNMENT REGULATIONS TO BE KEPT ONSITE & GIVEN TO ALL CONTRACTORS                                                     Linings used shall be approved for use in wet areas & shall be fixed in strict accordance
   WRITTEN DIMENSIONS TO TAKE PRECEDENCE OVER SCALE.                                                                       with Manufactures specifications. Wet Areas include Laundry & Bathroom
   BUILDER TO VERIFY ALL SET-OUT DIMENSIONS PRIOR TO PLACEMENT OF CONCRETE
   BUILDING MUST COMPLY WITH THE NATIONAL CONSTRUCTION CODES (BCA) & THE QUEENSLAND HOME BUILDING CODE                     All walls to be checked to ensure they are fixed correctly, straight & plumb prior to fixing plasterboard or interior lining
   ALL CONCRETE SLABS & FOOTINGS TO COMPLY WITH (AS 2870)                                                                  Plasterboard or interior linings to be fixed to dry frames in strict compliance with manufactures details. Setting of plasterboard to be done in strict
   ALL STRUCTURAL TIMBERS TO COMPLY WITH NATIONAL TIMBER FRAMING CODES (AS1684.2 &AS1720) & CONSTRUCTION TIMBERS           compliance with manufactures specifications, Sanded to provide a flat smooth finish
   IN QUEENSLAND (CTIQ)
   TERMITE PROTECTION TO (AS3660.1) CERTIFICATES TO BE SUPPLIED & GIVEN TO CERTIFIER                                       Painting: Paints & application to comply to AS 2311 Min 3 coat application system to be used
   ALL WET AREAS TO BE WATERPROOFED, INTERNAL WATERPROOFING TO COMPLY TO (AS 3740) AS IN BCA 3.8.1                         Substrate to be clean & dry correct type sealers & primers to be used for substrate
   ALL GLASS TO COMPLY TO (AS 1288) WINDOWS & DOORS ALONG WITH SCREENING OR SECURITY SCREENS TO COMPLY TO                  If paint is sprayed on then a back roll should be done between coats & after final coat
   RELEVANT REGULATIONS                                                                                                    Mould resistant paint to be used in Bathrooms, Ceilings to have approved ceiling paint applied & be a matt finish
   PLASTERBOARD TO (AS 2589), PAINTING TO COMPLY TO (AS 2311) TILING TO COMPLY TO (AS 3958)
   STAIRS TO COMPLY TO BCA 3.9.1 BALUSTRADE TO COMPLY TO BCA 3.9.2,                                                        Concrete slabs & footings to be poured AS per Plans & in accord with AS 2870
   WIND CLASSIFICATION (N3).                                                                                               Slabs shall be finished to suit floor coverings

                                                                                                                           All external windows & doors to have appropriate flashing & seals fitted to prevent water getting into building or
                                                                                                                           to the frame work




       APPROVED PLAN
         51983.3225.09
       NOOSA COUNCIL
        1 AUGUST 2017
Client: M & K Himgston       Unit 20/30 Hasting St. The Hastings Noosa Heads                  Wind Classification N3                                                                             Mobile: 0407 693 018                                Date     23/03/2017 3:20:18 PM
                                                                                                                       ACCOLADE Building Designs                                                                                                    Drawn by: S.Horn Drawn for A3 Sheet
RPD: Lot 20 on GTP 1154         Parish: Weyba       County: March       Site Area : 106 m²                                  Proprietor: Steven Horn                                   Email: [email protected] Project Number
                                                                                                                                                                                                                                                                                     1016HMK
Proposed Partial Enclosure of Ground Level Under Existing Unit                                                                 QBSA Lic. 54806                                        Issue Date            23 - March - 2017                            Sheet No. 1          of      6
Log in to download the original file

SUPERSEDED - Compiled Approved Plans 51983 3225 15.pdf · 28.0 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.