FIELD INLET PIT
900x900
GRATED LID
SL6.71
IL5.31
DEPTH 1.40
DN375 (1) x 15° BEND
FH
DN375 HEADWALL DN375 (1) x 15° BEND
WITH D50=200mm
AREA=7.5m2
DN375 DN375 (1) x 30° BEND
D
N
37
DN375 DN3
5
GROUT EXISTING PIPE 75
PENETRATION & PROVIDE NEW PIPE
PENETRATION TO SUIT 1.1% GRADE D
N
37 EXISTING NOOSA CIVIC
5 DN375 (1) x 22.5° BEND
DN375 STORMPRO PIPE DN375 (1) x 15° BEND
GRADE 1.1% DN375 STORMPRO PIPE
GRADE 0.95%
DN375 (2) x 45° BEND
CONSTRUCT NEW 900x900
(INTERNAL) CAST IN-SITUFH
FIELD INLET PIT
CONCRETE FIELD INLET WITH 150mm 900x900
WALL. FLUSH GRATE CLASS D GRATED LID
SL6.80
LOT 21
IL5.45 3825m² EX FIELD INLET PIT
DEPTH 1.35 600x600
GRATED LID
FH
SL6.96
IL6.09
DEPTH 0.87
CORE DRILL INTO EXISTING FIELD INLET PIT
STORMWATER PIT & PROVIDE NEW HO 600x600
INLET. CONTRACTOR TO CONFIRM GRATED LID
LEVEL PRIOR TO WORKS COMMENCING
FM
FH
SL5.20 BREAK UP & REMOVE EXISTING DN375
IL4.60 STORMWATER PIPE & HEADWALL TO TIP
AN
DEPTH 0.60
N
DR
IVE
LOT 19
3150m²
PROVIDE TABLE DRAIN ALONG THE
FRONTAGE OF LOTS 19-17 & GRADE TO
EXISTING GULLY TO THE EAST. PROVIDE
1:2 BATTERS 1.5m WIDE TO INVERT
ATTENTION: STORMWATER PIPES
ALL STORMWATER PIPES ARE TO BE
REINFORCED CONCRETE PIPES (RCP) LOT 18
WITH RRJ JOINTS UP TO DN750 THERE
AFTER TO BE FLUSH JOINT (FJ) 3243m²
ATTENTION:
JOINS PLAN 1856-SW07
IT IS THE CONTRACTORS RESPONSIBILITY FH
TO NOTIFY THE ADJACENT PROPERTY
LOT 17
OWNERS PRIOR TO ANY WORKS
COMMENCING ONSITE FOR LOT 18 DRIVEWAY PROVIDE 3719m²
DN450 RCP SW PIPE AS IPWEAQ
RS-056 FOR LOT 17 DRIVEWAY PROVIDE
CAUTION: DN525 RCP SW PIPE AS IPWEAQ RS-056
EXISTING SERVICES THE CONTRACTOR IS HO
TO DETERMINE THE EXACT LOCATION OF FM
ALL EXISTING SERVICES IN THE VICINITY AN
OF THE PROPOSED WORKS PRIOR TO THE N LOT 3
D
START OF ANY CONSTRUCTION. THE COST RI 4.004 Ha
VE
OF ANY RECTIFICATION WORKS DUE TO
DAMAGE TO EXISTING SERVICES SHALL BE FOR STRUCTURE OUTLET DETAIL
BORNE BY THE CONTRACTOR. REFER TO PLAN 1856-SW29
UNIT
COMPLEX
FH
DN
60
0
JOINS PLAN 1856-SW06
PROJECT: JOB NUMBER
REV DATE DESCRIPTION BY CHKD DRAWN
I GDETAL
IS SCALE APPROVED PROPOSED SUBDIVISION 1856
A 19-02-20 FOR APPROVAL MM CL AT NOOSA CIVIC, WALTER HAY DRIVE
B 24-08-20 REVISED STORMWATER ALIGNMENT MM CL DATUM AHD SHEET: 8 OF 30
0 10 20 30 40 50m
FOR STOCKWELL PTY LTD
DESIGN MM ................. DRAWING NUMBER REV
DRAWING TITLE:
DRAWN MM Director: CAMERON LANDRETH
SCALE 1:1000 A3 p 07 5443 8285 ABN 89 215 591 077
DESIGN CHECK (RPEQ 19358) e [email protected] w www.barlowshelley.com.au
STORMWATER LAYOUT PLAN 4 OF 8 SW08 B
CL
This drawing is not to be copied or amended without written permission from a PO Box 899, Maroochydore,4558
DATE 13-09-19 Barlow Shelley Consulting Engineers