Site Catchment Areas for DRAINS Modelling
Project number:    20220072                                         Calculations:                       B. Parry
Street Address:    15 Ross Crescent
Locality:          Sunshine Beach, NSC                              Date:                               24/08/2022


Existing Site
                                            Existing Site           Directly connected (m²)             Indirectly connected (m²)
15 Ross Crescent   Roof                                     129.8                               129.8                                  -
                   Impervious Ground                         39.5                                 -                                   39.5
                   Driveway                                  85.1                                85.1                                  -

                   Total Imp                                254.4                               214.9                                 39.5
                   Total Per                                351.9                                 -                                  351.9
                   Site Area                                606.3                               214.9                                 39.5

% impervious                                                        Effective DCIA = 75% DCIA           ICIA +25% ineffective DCIA
                                                                                                161.2                                 93.2
                   Impervious                               42.0%                               26.6%                                15.4%
                   Pervious                                 58.0%



Proposed Site



                                            Proposed                Directly connected (m²)             Indirectly connected (m²)
15 Ross Crescent   Roof                                     295.8                               295.8                                  -
                   Impervious Ground                         10.8                                10.8                                  -
                   Driveway                                  96.6                                96.6                                  -

                   Total Imp                                403.2                               403.2                                  -
                   Total Per                                203.1                                 -                                  203.1
                   Site Area                                606.3                               403.2                                203.1

% impervious                                                        Effective DCIA = 75% DCIA           ICIA +25% ineffective DCIA
                                                                                                302.4                                100.8
                   Impervious                               66.5%                               49.9%                                16.6%
                   Pervious                                 33.5%
Log in to download the original file

RFI - 20220072 Ross Cr SWMP.pdf · 3.5 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.