Amended plans
Attached to the e-mail MCU22/0207 & OPW22/0314 - Response to Council’s Information Request - 24 Wesley Court Noosa Heads.
Plans and drawings: the text below has words only, no drawings.
GENERAL NOTES
lot 45 on N21844
24 wesley court, noosa heads 4567 TIMBER FRAMING AND CONSTRUCTION
1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH
THE AUSTRALIAN DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH
AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL.
3. PINE FRAMING TO BE MINIUMUM STRESS GRADE
MGP 10/MGP12
4.HARDWOOD FRAMING TO BE MINIMUM STRESS
GRADE F14 & MINIMUM JOINT GROUP J2.
5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
SPECIFICATIONS ALL OTHER FIXINGS TO BE IN
ACCORDANCE WITH AS 1684.2 2010
7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN
3070 TABLES WHERE OTHER BRANDS ARE USED, SIZES TO
BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS.
proposed powder coated 8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
aluminium framed structure + 9. BUILDER AND TRADES ARE TO CONFIRM ALL
tinted glass sheeting over proposed structural aluminium MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO
painted black existing upper powder coated pergola SETOUT AND ORDERING OF MATERIALS
1085 floor as per engineers design 10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER
existing rafters
AS NO RESPONSIBILITY WILL BE TAKEN AFTER
150
CONSTRUCTION HAS COMMENCED
2335 1695 11. ALL TRADES ARE TO CONFORM WITH THE
5350 100x100 shs post CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR
from natural ground line
in line with master
2790
HER OWN WORK
in line with structure
2540
2540
2540
2540
2400
2400
suite wall behind 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS
3790
3660.1.2000
1200
deck extension balustrading as per
existing existing deck (cantilevered) existing deck aus standards
DOMESTIC SMOKE ALARMS
1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED
1100
WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE
proposed aluminium WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT
Section 1 existing height underside of
covered deck
950 framed sliding gate under REGULATION 2016
2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE
proposed to suit in line
WITH AS 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL
AND INTERCOM SYSTEMS.
3. DEVICES MUST BE INTERCONNECTED AND HARD
Section 2 WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE
REMOVED FROM DEVICE
4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND
BEDROOMS TO EXISTING RESIDENCES
S INDICATES THE LOCATION OF WIRED SMOKE ALARMS
GLAZING
1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND
SUBJECT TO CONFIRMATION UPON SITE MEASURE
2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT
aluminium powdercoated pergola proposed aluminium TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR
+ tinted glass sheets over angle blade framed screen PRIVACY OPTIONS
in line with existing floor details + installation
over as per engineers design as per manufacturers specifications ELECTRICAL AND ENERGY EFFICIENCY
existing master
1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER
pavillion existing upper floor
AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED
INDICATIVE ONLY
5680 proposed timber
boundary line
frame in line with DOWNPIPES
existing brick wall ALL LOCATED DOWNPIPES INDICATIVE ONLY AND
2650
100x100 shs post pergola
details tie down as per engineers design+ to propose bbq bench existing boundary fence existing existing garden CONFIRMED AT TIME OF ROOFING CONSTRUCTION
manufacturers specifications + deck AND COMPLIANCE
master
existing deck proposed deck extension existing deck pavillion 0 10000
deck joist system as
Section 3 per engineers design existing slab proposed jetty
deck joist system + concrete pilings
details as per jetty specialists specifications
+ engineers design Section 4
sections
NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC
PROPOSED: CLIENT: CATHERINE + BUILDER: NOOSA'S OWN BUILDING MANDY'S DRAFTING ONLY SHEET: 7 of 7 DATE: ISSUE NO:
EXTENSION + JETTY ROBERT MARTYR + MAINTENANCE PH: 5474 1906 QBCC:1254229 PH: 0403 481 474 SCALE: 1:100 16 FEB 2023 CR-2023-K
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH