ae : © 281°20'25" ¢ 7

    
 

garden

  
  
 

pool equip.

      
 
 
 
   

tv room

carpet

  

 

RL 5650
driveway

pavers to match road

1
1
'
1
‘
i
'
5
1
'
1
'
‘
4
1
‘
1
'
‘
‘
'
\
'
'
'
‘
'
‘
'
‘
1
1
‘
‘
‘
1
‘
‘
\

‘
1

 
 

1

'
“| oo Rese Ss Se Settee SS
pS paring
21

a | ‘ Fa SSS Sekse cree ce
Retaining wall
| Max 600high
'

    

|
281°20'25" |

en ee on ee ws eo oe eo ee 8 ee ee ee ee ee ee

! | es
46.232 ;

t

1 |
'

'

\

1

'

'

 
  

GROUND FLOOR PLAN

REAL PROPERTY DESCRIPTION

!
t

2000 H conc. block wall
Site Area

Parish of Weyba

822.44 nv

County of March

Site Area 822m

Site Cover Allowed 287.7m2 Actual 256m2
Plot Ratio Allowed 411m2 Actual 412.86m2

AREAS
Decks
Terraces
Ground Floor
Upper Floor

Garage

Total Area(floors)

9,90m2
112.68m2
201.13m2
156.80m2

54.93m2

412.86m2

1:100 sa
" bt = BENCH TOP
b BATH
c CONCRETE
GENERAL NOTES cpd CUPBOARD
ct COOKTOP
Tefer to Internal elevations and plans for accurate dp DOWN PIPE
setout of plumbing postions dw DISHWASHER
ens ENSUITE
1, the builder shall check all dimension and levels hb HAND BASIN
on the site prior to any construction and shall hr HAND RAIL
report any descrepencies to the architect before hws HOT WATER SERVICE
proceeding

2. all working and material to be in accordance
with the building code of australia, the queensland
ACT, AS 1648 residential timber framed construct-
lon and other relevant SAA codes

3. the engineer has determined the site Is located In
a wind terrain category N2.5, region B, intermediate
zone with a design wind speed of 41 M per sec

4, stormwater and sewage disposal shall be to the
requirements of the local authority

5. the bulldings are to be protected from termite
infestation by term-mesh physical barriers in
accordance with AS 3660.1

6. these drawings are to be read In conjuction
with the structural drawings prepared by:
consulting engineers

 

@<gsese sgeasgaace

LAUNDRY
LINEN
OVER HANG
PANTRY
ROBE
REFRIGERATOR
SERVERY
SHELVES
TIMBER
TILES
SINK
SHOT EDGE BOARDING
SHOWER
TOILET
TUB
ROOF OVER HANG
BENCH OVEN
WALK IN ROBE
WASHING MACHINE
VANITY BENCH
SMOKE DETECTOR

 

Peter Hull Architect Pty Ltd
PO Box 407 Noosa Heads
Queensland 4567

T: 07 5455 4566 F: 07 54554677

E: [email protected]
ACN : 101 922 570

 

 

""(saacs Residence
Lot 56 The Palms Noosa Springs

Client:

Les & Annabelle Isaacs
Drawing Titie:

Site & Ground Floor Plan

 

 

Scale: Date: North:
4: 100 May 03
Drawing Number: Issue:

0208 WD 01

Used in these records

About this file

File size
23.5 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

existing approval planspdf.pdf · 23.5 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.